diff --git a/docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md b/docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md new file mode 100644 index 0000000..a26aec4 --- /dev/null +++ b/docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md @@ -0,0 +1,339 @@ +# Phase 5: changing a unit's settings by serial (design) + +**Date:** 2026-11-03. **Status:** draft for Brian. Phase 5 of +`docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (row 10, "change +recording settings"; build phase 5, "setup push: one field first, then several"). +**Branch:** `feat/series4-sfm-parity`. + +## Intent (Brian, 2026-11-03) + +Change **any** of a unit's settings from SFM, and make it as easy and reliable as +possible. The goal is to fix what makes Blastware finicky. Three real cases: + +- **One wrong number on a deployed unit.** UM6047 was out monitoring with its + geophone trigger at 0.03 instead of 0.300. Brian remoted into the THOR PC, + stopped it (it called in), changed the setup, made sure it was *sent*, then + restarted monitoring. +- **A typo in the notes.** +- **A backup unit.** The unit set up at the office fails in the field, so a backup + from the truck goes in with blank or stale notes and settings. There is no + computer in the field, so the office re-does the whole setup remotely, by hand, + while the person in the field stands by to press Start or power-cycle if the + link breaks. + +What is wrong with THOR, as Brian and his dad experience it: + +- The same screen edits a setup on disk and views a unit's setup. +- Setups get saved under random number strings. +- Editing a setup does not change the unit; you verify separately that it was sent. + +Saved setups as templates would be acceptable. Not knowing whether you are +changing the unit or a file is not. + +## Goals, non-goals, anti-goals + +**Goals** + +- Edit the unit's **live** settings, both series. +- Show exactly what will change, **old → new**, before anything is sent. +- After sending, **re-read the unit** and show what it now holds. +- Make every refusal say why, in plain words. + +**Non-goals (this phase)** + +- Templates, saved setups, copying from another unit. +- Restarting monitoring. **Brian presses Start**, as today; SFM never restarts on + its own. +- Setting the unit's clock. That is a later call-home receiver rule. +- Fields not yet decoded. "Any and all" grows as decoding grows. + +**Anti-goals: things that would make it a failure even if it "works"** + +- Any doubt about whether the unit changed. +- A screen where a file and a unit look alike, or a name SFM made up. +- Writing a byte SFM did not just read. Every byte SFM does not deliberately change + goes back exactly as read. The one exception is a byte that Blastware's (or + THOR's) own writes always set to a fixed value. Each such byte is named in the + codec with its evidence (so far: Series 3 `[26:28]` → `00 00`; my call, below). +- Sending to a monitoring unit. +- A retry. A write is sent once; what happened is read back. + +## Measured basis + +**1. Series 4 (Micromate): the `0x1A` setup content map.** Measured from 47 +keypad snapshots on UM20147 and checksum-verified. `micromate/setup_block.py` +(`decode_setup`) reads it, with 69 tests on 15 fixtures. + +| content | field | +|---|---| +| `[5]` | record mode | +| `[6:8]` | sample rate | +| `[8:10]` | histogram interval | +| `[12:16]` | pre-trigger, f32, negative | +| `[17]` | stop mode | +| `[18:22]` | record time, f32 | +| `[23]` | auto-stop | +| `[25]` | active sensors | +| `[29]` | trigger sources | +| `[30:34]` | distance | +| `[34:38]` | charge | +| `[39]` | report flags | +| `[40:42]` | job number | +| `[42:86]` | setup name | +| `[122+64n]` / `[144+64n]` | notes (label / value) | +| from `[1708]` | 48-byte channel blocks: sensor code `+4:8`, trigger `+30` (geo in/s, mic psi) | + +The CRC-16/AUG-CCITT over `[0:2088]` is stored at `[2090:2092]`; THOR's write +omits it and the unit recomputes it. + +- **The push sequence (from THOR's captures)** is `0xDA` (name) → `0x68`/`0x73` + (`0x08` preferences) → `0x82`/`0x83` (`0x2E` trigger) → `0x71`/`0x72` (`0x1A` + setup). `micromate.writes.plan_setup_push` reproduces THOR's frames (phase 2). +- **Not yet mapped on Series 4:** alarm level, geophone range, GPS, aux I/O, SLM + options. + +**2. Series 3 (MiniMate) uses the same layout. Measured 2026-11-03.** The +compliance image as Blastware writes it is logical (unescaped), 2,092 bytes, with +`N = 2090` at `[0:2]` and the channel block "Tran" at `[1708]`. +`micromate.setup_block.decode_setup` reads it correctly: + +- **BE9441's 10-26 write** (`tests/fixtures/minimate-bench-10-26-26-histogram`, + two whole sends): name, mode, 4096 sps, interval, record time 20 s, trigger + 0.04 in/s, mic linear, job number and the notes all decode. Only the CRC fails + (Series 3's tail goes out stale). +- **BE11529's nine 2026-04-20 Blastware writes** (`bridges/captures/4-20-26/`, + every one with a whole image) each changed exactly the expected bytes: + + | Blastware changed | bytes that moved | + |---|---| + | histogram interval (×4) | `[8:10]` | + | recording mode (×3) | `[5]` | + | geophone range | `1737` / `1785` / `1833`, the range byte at each geophone channel label `+29` | + +- **The live `SUB 1A` read starts the same block.** Measured on the first data + frame of each of the four recorded reads (`_settings_replies` in + `tests/test_s3_compliance_anchor_fields.py`): unescaped, each carries `N = 2090` + 12 bytes before the old "anchor", and content `[5]` reads 1 / 4 / 3 / 3. That + anchor (`be 80 00 00 00 00`) is content `[12:18]`, pre-trigger −0.25 plus stop + mode Fixed. So Series 3 can be read by content offset rather than by anchor + search, which survives an Auto-stop unit (the open question of 2026-10-17). +- **A whole `1A` read assembles to exactly the 2,090 content bytes** (measured + 2026-11-03 on BE9441's 10-26 recording, 12 reads). Unescape each data frame and + take `data[11:]`. Every frame but the last then starts with one `00` byte that is + not content; drop it. This holds for Blastware's read (four 512-byte frames plus + 42) and SFM's (two 1024-byte frames plus 42). + - **The round trip is exact.** Blastware re-read the block after each of its two + writes, and each re-read equals the image it had just written, all 2,090 bytes. + - **While monitoring**, the read returns `0e 'BE9441' …` (the device-info block), + as the 10-29 finding says. The unit was monitoring for 5 of the 12 reads. +- **Bytes `[26:28]`: Blastware always writes `00 00`** (all 11 writes), though the + unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19). + The unit sets them again by itself. Meaning unknown. +- **The two bytes after the block are Blastware's own.** Blastware sends a per-unit + constant: `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's. + It is not the block's CRC-16/AUG, and no reply in BE9441's three-hour session + contains it. SFM's `write_image` sends `00 00` there. Since a read never returns + those bytes, the read-back cannot show what the unit did with them. +- **The mode byte is shared, but its codes are not.** Series 3: `00` Single Shot, + `01` Continuous, `03` Histogram, `04` Histogram + Continuous. Series 4: `01` + Waveform, `02` Manual, `03` Histogram, `04` Combo. +- **Rules from the checker's file-side work** (seismo-relay-b6, 2026-11-03; it + measured the same content offsets on 70,042 event files and found nothing that + contradicts one shared map): + - A bitmask byte is patched **bit by bit, never rebuilt**. The trigger-sources + byte `[29]` showed an unidentified `0x80` bit on one unit. + - On Series 3, stop mode (`0` Fixed) and mic type (`2` linear) are proven for + one value each. They are not offered for writing. + - An event file's `[12:16]` is that event's captured pre-trigger, not the + setting. SFM writes only from a live read, so this matters only to anyone + tempted to build a write from a file. +- **Series-3-only fields** (measured on Series 3, not Series 4): the geophone range + byte at channel `+29`; the alarm level at channel `+38` (checker-measured on + event files; live raw `+42`). + +**3. Series 3 write frames are measured (#46).** Writes use uniform escaping with +a length field. The compliance image goes in 512-byte addressed chunks. `0x68` is +written as read plus `02 00`, `0x82` plus `00 00`. The sequence is +`68→73 | 71×n→72 | 82→83 | 69→74→72`. `push_config_raw` refuses any block that +is not whole. `tests/test_minimate_write_frames.py` rebuilds Blastware's frames +byte for byte. + +**4. Monitoring.** + +- **Series 3:** while monitoring, the unit answers `1A` (and `0x2C`) with its + device-info block (measured 10-29 and 11-03). +- **Series 4:** it refuses call-home setup while monitoring ("Feature disabled + while monitoring", measured 11-03). +- **A stop with call-home on makes the unit call in** (measured 10-25, 10-29, + 11-03). + +**5. Series 4 specifics.** + +- `0x1A` reads the keypad's edit buffer live: unsaved keypad edits show in the + read, and a push would commit them. +- Loading a `.MMB` replaces the active config byte for byte. The push writes + under the active setup's name (`0xDA`). + +## The flow + +1. **Read.** `GET /device/settings?serial=…` (it exists) returns the unit's + settings. The page shows them on the Config tab under **"On the unit BE9441 — + read 14:03"**, never anything that looks like a file. +2. **Edit and preview.** The operator changes fields, then **Preview**: a dry run. + SFM re-reads the unit's blocks on the same line, builds the new blocks, and + returns one row per field: **old → new**, plus any warnings. Nothing is sent. +3. **Send.** The same request, live, is an audited change: + - identity check, audit row, one send, never retried, read back; + - **refused with "stop monitoring first"** if the unit is monitoring, noting + that the stop makes it call in when call-home is on; + - **refused** if the unit's settings changed since the preview. The preview + carries a revision (a hash of the blocks read), and the live call must + match it. +4. **Verify.** Re-read the blocks. Every changed field must read its new value. + Every other decoded field, and every byte SFM did not deliberately change, must + read as before. The page shows **"the unit now holds"**: field, old, new, now. + Known unit-maintained bytes (the Series-4 CRC) are compared as the unit's own + checksum (`crc_ok`), not byte for byte. +5. **Start** stays the operator's button. + +## Fields in the first version (Brian approved the list) + +| field | Series 3 | Series 4 | +|---|---|---| +| geophone trigger level | yes (channel `+30`) | yes (channel `+30`) | +| alarm level | yes (channel `+38`; measure live) | not mapped, so not offered | +| notes: the four note slots, by the unit's own labels | yes (`Project:`, `Client:`, `User Name:`, `Seis. Loc:` on BE9441) | yes (`Location`, `Client`, `Company`, `General Notes`) | +| recording mode | yes (`[5]`; values as measured on Series 3) | yes (`[5]`; Series-4 codes) | +| sample rate | yes | yes | +| record time | yes | yes | +| histogram interval | yes | yes | +| geophone range | yes (channel `+29`) | not mapped, so not offered | +| job number (+ shown on report) | yes | yes | + +A field is offered only where it is measured for that series. Values are refused +unless they are among the measured choices: sample rates 1024/2048/4096, +intervals 2/5/15/60/300/900 s, and each series' measured mode codes. + +- **Numbers (my call; no unit limits are written down anywhere in the repo):** + - Refuse any value outside the span seen on real units. The builder derives + each span from the DL2 XML reports, the fixtures and the captures, and records + it in the codec with its source. SFM then never sends a value no unit has + been seen to hold. A span can be widened later on evidence. + - A geophone trigger or alarm must also be at or below the range's full scale + (10 / 1.25 in/s). When range and trigger change in one request, check the + trigger against the **new** range. + - **Units:** refuse a level write unless the channel's unit string reads the + measured one (`in.` for a geophone). A unit set to Metric is unmeasured. +- **Notes:** edited by slot, under the label the unit itself shows (labels can be + renamed and are not identifiers). The value is at most its field width less + one byte, printable ASCII. + - Not in v1: Series 3's fifth slot, `Extended Notes` (value `\n` on BE9441). + Blastware's extended notes are unmeasured and may live elsewhere. + - Not in v1: Series 4's 16-byte field at content `[1064]` (`Loc 1` on + UM12947), undecoded. + +## Architecture + +- **One setup-block codec for both series.** Keep `micromate/setup_block.py` as + the field map and add `encode_setup(content, changes) -> content`: field patches + only, every other byte as given. It stays a pure codec library: no I/O, no + `sfm` imports, no import cycle with `minimateplus`. Series-specific fields (the + Series-3 range and alarm) are marked by series. +- **Series 3 read.** Assemble the `1A` read into the logical 2,090-byte block: + unescape, strip the 12-byte reply prefix and the inter-frame headers + (`read_compliance_config`). Decode it by content offset. +- **Series 3 write.** The patched logical block plus the tail becomes the + compliance image for `push_config_raw`. Event index (`0x08`), trigger (`0x2E`) + and waveform data (`0x09`) are echoed as read, in Blastware's sequence. + - On `0x09`, Blastware echoed the unit's bytes on all nine April writes + (`[200:202]` = `8c 76` read and written). Only BE9441's 10-26 writes changed + them (`17 17` read, `78 76` written, and read back so). The meaning is + unknown, so SFM echoes. + - **The raw-offset `_encode_compliance_config` is retired.** +- **The legacy write (`/device/config`, `/device/config/project`) is retired (my + call).** It retries a whole write on a TCP error, is not audited, does no + read-back, does not refuse a monitoring unit, and needs no serial: every + anti-goal at once. Its only user is the webapp's by-host Config form, and + Terra-View does not call it. Its routes answer with a pointer to the by-serial + change, and the by-host form becomes read-only. +- **Series 4 write.** `plan_setup_push(prefs, trigger, patched_setup, name)`. + - **No setup files in the operator's view (Brian, 2026-11-03).** "We treat the + Micromate setups just like Minimate setups … the unit just has its settings, + and we change it based on the job. We don't send setups to the unit." A + backup unit is usually on whatever setup its previous job left. So SFM + rewrites the setup the unit is running, in place, under its own name. It + never asks for a file or a name, and never creates one. The name may show as + a read-only detail, since the unit's screen shows it. + - The name comes from the `0x41` read, unstripped. + - Refuse `factory.MMB` and any target that is not the active setup (spec). The + refusal says it plainly: "this unit is running its factory setup; load any + other setup on its keypad, then try again." Brian says the team does not use + the factory setup, so this should be rare. + - `ENABLEABLE_WRITES` gains `0xDA 0x68 0x73 0x82 0x83 0x71 0x72`. + - The keypad edit buffer: warn in the preview that a unit with someone in its + menu would have those edits committed. The check the spec names, `0x1A` + against the active `.MMB` via `0x94`/`0x48`, is a bench question first. +- **The change path.** It keeps run_change's guarantees: identity, audit, one + send, read back, `ChangeUnconfirmed` with `sent`/`audit_id`. The "state" is a + set of fields, so either `run_change` takes a verify function or a sibling core + shares its parts. The builder decides; the guarantees do not change. The audit + row keeps the per-field changes, both blocks (hex) and the verdict. +- **Routes.** `POST /device/settings/change?serial=…` (serial required) with body + `{changes: {field: value}, revision}` and `dry_run`, `caller`. The response is + per-field `old` / `new` / `now`, through `_change_response`. A dry run needs no + revision and returns one. **A live call without the revision of a preview is + refused** (my call): nothing reaches a unit unless someone saw old → new. +- **Page.** The Config tab by serial becomes the unit's edit form: Preview → Send + (confirm) → "the unit now holds". New logic goes in + `sfm/static/device_routing.js` with Node tests, and glue in + `sfm/static/sfm_webapp.js` (no inline JS). + +## Verification + +- **Series 3, byte for byte.** For each of the 11 Blastware compliance writes, + apply the new encoder to the read before it (or the previous image), with the + fields Blastware changed. It must reproduce Blastware's content `[0:2090]`. The + two trailing bytes are compared separately, since they are Blastware's constant. + Ten writes change one field. BE9441's 16:26 write changes five things: mode, + sample rate 2048 → 4096, interval, the mic in the sensors byte `[25]`, and + `[26:28]`. That one is tested with all of them, through the codec, though v1's + page does not offer the sensors byte. + The frames rebuild through `push_config_raw`'s path (the #46 tests). +- **Series 3, read side.** The assembly rule above, pinned as a test on the 12 + reads of BE9441's 10-26 recording. Each read-back equals the write before it. +- **Series 4.** THOR's setup-push captures still reproduce, with no field changed. + Any capture where THOR changed a field becomes a byte-for-byte test. +- **Bench, with Brian's go per send, per series:** + 1. A dry run of a trigger change, then send, read back, check the unit's menu, + and change it back. + 2. A notes change. + 3. A several-field "backup unit" change. + 4. A dry run while monitoring, expecting the refusal. + +## Calls I made (Claude), for Brian to check + +- **Series 3 `[26:28]` goes out as `00 00`, as Blastware writes it**, rather than + the `01 7f` the unit may read. Measured beats inferred: Blastware's value is on + 11 accepted writes, and writing back `01 7f` has never been tried. +- **The two bytes after the Series 3 block stay `00 00`**, as `write_image` sends + them (a unit accepted that in the April 2026 test). Blastware's per-unit + constant cannot be derived from anything SFM reads. The first bench write checks + that the unit takes the block, and its menu shows the change. +- **The `0x09` block is echoed as read**, as Blastware did on all nine April writes. +- **Numbers are bounded by what real units have been seen to hold**, and level + writes are refused unless the channel's unit string is the measured `in.`. +- **Notes are edited by slot under the unit's own labels**, four slots on each + series. Series 3 extended notes and Series 4's separate location field wait. +- **The legacy by-host write is retired**; the by-host form becomes read-only. +- **A live send needs a preview's revision.** +- **Preview re-reads the unit** rather than trusting the page's copy, and Send + refuses if the unit changed since the preview. +- **The edit form lives on the Config tab, by serial**, replacing the legacy + read-modify-write form for units reached by serial. + +## Left to the builder + +- The module layout for the shared codec, within the no-cycle, pure-codec rule. +- `run_change` generalised versus a sibling core. +- The exact revision hash. +- Page layout details.