diff --git a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md index f14758a..cd28f6c 100644 --- a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md +++ b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md @@ -740,6 +740,20 @@ items were left for later on purpose: ## Parking lot +- **Speed (Brian's goal: faster than Blastware), after 1c.** Measured on + BE9441, 2026-10-27 23:41, serial cable: + - wake + serial number take 0.16 s; + - `MiniMateClient.connect()` also reads 01 + 1A + 08 on every request, ~3 s; + - a fixed **2.0 s "safety drain"** at the end of `read_compliance_config` runs + on every connect; + - the read-back polls every 2 s. + + Ideas, each measured before and after against Blastware's own timings in the + bridge recordings: a light connect (wake + serial) for start/stop, status and + event list; drop or shorten the drain; reuse within a session (MiniMates + reconnect per request). New safeguards must state their time cost + (1c's identity check reuses the serial read connect already does). + **Monitor logs.** Its own piece of work, data side as much as device side. A unit calls in at least once or twice a day. With no events (e.g. waveform mode, no blast that day) it still delivers a **monitor log**: "monitoring from