feat(sfm): call-home state and enable/disable by serial -- GET /device/call_home/state, POST /device/call_home/{enable,disable} (phase 4)

- DeviceAccess.call_home_state (a read) and set_call_home (change=True: never
  retried, audit required for a live change, dry run without one), routed by
  series like start/stop.  A config write is read back on its own window: up
  to 3 reads, 1 s apart, not the monitoring one.
- Routes, serial required (422 without), all three serial-aware: the state as
  a dict; enable / disable through _change_response, so their statuses are
  start/stop's and an unconfirmed change carries sent + audit_id.  The legacy
  GET / POST /device/call_home are unchanged (a Micromate serial is still
  refused there, 501).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 17:01:14 -05:00
1 parent 453d42e32a
commit 06fa56db09
4 files changed
+233 -3

No files matched your search

+59
View File
@@ -425,6 +425,7 @@ _SERIAL_AWARE_PATHS = frozenset({
"/device/info", "/device/connect", "/device/monitor/status", "/device/settings",
"/device/events", "/device/events/download",
"/device/monitor/start", "/device/monitor/stop",
"/device/call_home/state", "/device/call_home/enable", "/device/call_home/disable",
})
@@ -2055,6 +2056,64 @@ def device_monitor_stop(
# ── Call home config endpoints ───────────────────────────────────────────────
@app.get("/device/call_home/state")
def device_call_home_state(
serial: str = Query(..., description=_SERIAL_DOC),
host: Optional[str] = Query(None, description="TCP host — modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
) -> dict:
"""The unit's call-home switch and dial string, by serial, both series (phase 4).
`enabled` is null when the enable byte is not a value ever measured;
`detail` keeps `byte5` and the whole block as read."""
return _via_device_access(lambda: _device_access().call_home_state(
_unit_address(port, baud, host, tcp_port), serial))
def _set_call_home(enabled: bool, port, baud, host, tcp_port, serial, dry_run, even_if_already, caller):
return _change_response(lambda: _device_access().set_call_home(
_unit_address(port, baud, host, tcp_port), serial, enabled=enabled, dry_run=dry_run,
even_if_already=even_if_already, caller=caller or "api"))
@app.post("/device/call_home/enable")
def device_call_home_enable(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: str = Query(..., description=_SERIAL_DOC),
dry_run: bool = Query(False, description="Return the planned frames; send nothing"),
even_if_already: bool = Query(False, description="Send even if call-home is already on"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""Turn the unit's automatic call-home ON (spec row 9), by serial, both series.
The same audited change as /device/monitor/start: identity read first (a
different unit is a 409, nothing sent), the 0x2C block read, one write that
changes only the enable byte (0x7E + 0x7F), never retried, then read back.
Statuses as /device/monitor/start; a change that went out but was not
confirmed carries `sent` and `audit_id`."""
return _set_call_home(True, port, baud, host, tcp_port, serial, dry_run, even_if_already, caller)
@app.post("/device/call_home/disable")
def device_call_home_disable(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: str = Query(..., description=_SERIAL_DOC),
dry_run: bool = Query(False, description="Return the planned frames; send nothing"),
even_if_already: bool = Query(False, description="Send even if call-home is already off"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""Turn the unit's automatic call-home OFF -- as /device/call_home/enable."""
return _set_call_home(False, port, baud, host, tcp_port, serial, dry_run, even_if_already, caller)
@app.get("/device/call_home")
def device_call_home_get(