From 073284fc88b61ac761e8a750a07cb3ddbcb96ead Mon Sep 17 00:00:00 2001 From: serversdown Date: Thu, 29 Oct 2026 12:01:39 -0400 Subject: [PATCH] docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes - CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows the unit's own answer, writes off until phases 4-5, the Node-run page tests) and the legacy-route guard in the REST API notes, with why the stop tools are exempt. - Spec: the 1c build status; the ring-path Runs A/B are still owed before serial mode is used on a unit that calls home to THOR; which parked 1c items the page settles (CORS: same origin; the S4 mic is not shown). Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44 --- CLAUDE.md | 37 ++++++++++++++++++- .../2026-10-20-sfm-series4-parity-design.md | 24 ++++++++++++ 2 files changed, 60 insertions(+), 1 deletion(-) diff --git a/CLAUDE.md b/CLAUDE.md index 1de231b..8def3a0 100644 --- a/CLAUDE.md +++ b/CLAUDE.md @@ -164,7 +164,37 @@ Read this first when picking the project back up. start's read-back waited out the ~30 s sensor check and re-sent the wake (`9886422`, `ca5c401`; a monitoring MiniMate answers nothing until woken, and nothing during its sensor check). Still owed before merge: #47 from dev, and - `persist_download` aligned with dev's waveform-time restamp (spec). Next: 1c. + `persist_download` aligned with dev's waveform-time restamp (spec). +- **Phase 1c: the SFM webapp by serial (2026-10-29), built; bench pass owed.** + `sfm/sfm_webapp.html` has a **Serial** field beside host/port. With one, the + Live tabs use the serial-based routes for both series: identify, status (now + with the unit's clock and event count), settings (read-only), the event list + with a Download per row (checked, stored, then opened from the store), and + audited start/stop (asks first, one send, shows the ChangeResult as it is). + Hang up appears for a Series 4. Every series-specific control follows the + unit's own `/device/info` answer, never the typed serial, and drops the + moment the serial, host or port is edited. Config and call-home **writes are + off for both series** (phases 5 and 4); Diagnostics is enabled only for a + confirmed Series 3. Without a serial every read behaves as before. + The page keeps every routing and button rule in one block of pure functions + between `/* */` markers, run through **Node** by + `tests/test_webapp_device_routing.py` (skipped when `node` is absent); a + static test fails if a `/device/` URL is built anywhere else. + **Server side:** the legacy Series-3 writes and erase -- `POST /device/config` + (and `/config/project`), `/events/erase`, `/rescue` (when it disables ACH or + erases), `POST /device/call_home` -- read the unit's serial (or reuse the one + `connect()` read) and refuse 409, nothing sent, unless it is Series 3 and, + when `serial=` was given, that unit. 0xA2 is CONFIRM ERASE on a MiniMate and + ends a call-home on a Micromate. The stop tools (legacy `monitor/start|stop`, + `stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt: 0x96/0x97 mean + the same on both series, and the blind tools must reach a unit too wedged to + answer. + ⚠ **Before serial mode is used on a unit that calls home to THOR, run the + ring-path Runs A/B** (spec, *Open questions ... for the bench*): a held line + holds the modem's single TCP session. The page never polls (every request is + a click), SFM hangs up on RADIO RING, and **Hang up** releases the line at + once; whether a call-home still reaches THOR is unmeasured. + Next: the bench pass on BE9441 and UM20147, then phases 4 and 5. - **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built, reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in 0.46 s and read back as monitoring at the first 2 s poll (during the sensor @@ -1582,6 +1612,11 @@ POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Serie nothing; `even_if_already=true` sends even when the unit is already in that state). A `UM` serial on any other `/device/*` route is 501; any request taking the legacy Series-3 path at a held Series-4 address is 409. +The legacy Series-3 writes and erase (`POST /device/config`, `/config/project`, +`/events/erase`, `/rescue`, `POST /device/call_home`) take an optional `serial=` and +refuse 409, nothing sent, when the unit at the address does not answer as Series 3 +or is not the named unit. The stop tools (`monitor/start|stop` without a serial, +`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt by design. SFM must run a single uvicorn worker (locks and held lines are per process). Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing). diff --git a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md index e256072..6b10e95 100644 --- a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md +++ b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md @@ -490,6 +490,30 @@ Each safety piece arrives with its first real use, so nothing sits untested. address answer 503 + `Retry-After` until it expires, and `POST /device/hangup` clears it, with its length taken from Run A. If THOR gets the call anyway, no cool-down is needed. + - **Built 2026-10-29** (plan `docs/superpowers/plans/2026-10-28-sfm-phase1c-webapp.md`). + A Serial field beside host/port; with one, identify, status, settings + (read-only), events (a Download per row) and audited start/stop go + through the serial routes for both series, and Hang up shows for a + Series 4. Series-specific controls follow the unit's own `/device/info` + answer and drop when the serial, host or port is edited; config and + call-home writes are off for both series until phases 5 and 4; + Diagnostics needs a confirmed Series 3. Without a serial the page reads + as before. The rules are pure functions in one marked block, tested + through Node (`tests/test_webapp_device_routing.py`). + **Server side, the same phase:** the legacy Series-3 writes and erase + (`/device/config`, `/config/project`, `/events/erase`, `/rescue`, + `POST /device/call_home`) refuse 409 before any write unless the unit + answers as Series 3 (and as the named unit, given `serial=`). The stop + tools stay exempt: 0x96/0x97 mean the same on both series. + - ⚠ **The ring-path Runs A/B have not been run.** The page does not poll + (every request is a click), SFM hangs up on RADIO RING, and Hang up + releases a held line, but whether a call-home reaches THOR while SFM + holds the line is unmeasured. Run them before serial mode is used on a + unit that calls home to THOR, i.e. before this branch merges. + - Of the items parked for 1c below: **CORS ordering** does not bite the + page, which SFM serves itself (same origin); the **Series-4 mic** is not + shown (the event list shows geophone peaks only). The rest are server-side + and stay open. 2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still nothing sent. (2026-10-22) "Dry run" in this phase means the **write plan**: the exact