feat(checker): read each mic value in the unit Blastware printed; carve out mixed columns

Blastware's dB(L) / psi(L) labels do not hold for the mic on every
report (DL2, 2026-11-09):
- the mic peak carries its own <Units>, which 7 reports set to dB under
  a psi Units line and 3 the reverse: the checker now reads the peak in
  its own unit;
- a mic sample table has no unit of its own and need not follow the
  line (S353JTHU.DT0W prints dB under psi): the checker reads it from
  its cells -- a mic dB value is never under 60, psi never over 1;
- some reports mix the two inside one column: K441L9IN.OT0W prints psi
  '0.000' for counts of 1 to 3 in a dB table.  Carve-out
  mic-units-mixed accepts a mic field when every cell SFM disagrees
  with is SFM's own value in the other unit: 19 DL2 events (14 sample
  tables, 5 peaks); a cell matching neither stays a mismatch.

Not a decoder change: SFM's mic data were right.  Checker run
20261109-141808: 78 of 88 fields, 0 regressions; no mic peak or mic
sample table mismatches left.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-09 14:44:11 -05:00
1 parent e21d23a3f2
commit 0b6150adb5
9 files changed
+25513 -4

No files matched your search

+23 -2
View File
@@ -272,8 +272,25 @@ def _same_text(a: object, b: str) -> bool:
return " ".join(str(a).split()) == " ".join(b.split())
def _mic_table_units(ref: XmlReport) -> str:
"""The unit a report's mic sample table is printed in. Its cells say so --
a mic dB value is never under 60, psi never over 1 -- where the event's
Units line need not: S353JTHU.DT0W prints dB under psi (2026-11-09)."""
if ref.sample_rows and "MicL" in ref.channels:
i, seen = ref.channels.index("MicL"), False
for row in ref.sample_rows:
p = _printed_number(row[i]) if len(row) == len(ref.channels) else None
if p is not None:
if abs(p[0]) > 1.0:
return "dB(L)"
seen = True
if seen:
return "psi(L)"
return ref.event_units or ""
def _mic_converter(ref: XmlReport, sfm: SfmSide) -> Optional[Callable[[int], float]]:
units = ref.event_units or ""
units = _mic_table_units(ref)
d = sfm.mic_divisor
if "dB(L)" in units:
return lambda c: mic_count_to_db(c / d)
@@ -293,7 +310,11 @@ def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> Fie
if tag in ("MicLPSPL", "MicTriggerLevel"):
# A printed value that states its unit is compared in that unit:
# K441LA17.IN0W's Units say psi(L), its MicTriggerLevel "125.0 dB(L)".
units = printed if ("dB(L)" in printed or "psi(L)" in printed) else (ref.event_units or "")
# Else the field's own <Units>, then the event's line: 7 DL2 reports
# print the mic peak in dB under a psi line, 3 the reverse (2026-11-09).
own = ref.units.get(tag) or ""
units = (printed if ("dB(L)" in printed or "psi(L)" in printed)
else own if ("dB(L)" in own or "psi(L)" in own) else (ref.event_units or ""))
key = (f"{tag} dB(L)" if "dB(L)" in units else
f"{tag} psi(L)" if "psi(L)" in units else None)
value = sfm.values.get(key) if key else None