feat(checker): read each mic value in the unit Blastware printed; carve out mixed columns

Blastware's dB(L) / psi(L) labels do not hold for the mic on every
report (DL2, 2026-11-09):
- the mic peak carries its own <Units>, which 7 reports set to dB under
  a psi Units line and 3 the reverse: the checker now reads the peak in
  its own unit;
- a mic sample table has no unit of its own and need not follow the
  line (S353JTHU.DT0W prints dB under psi): the checker reads it from
  its cells -- a mic dB value is never under 60, psi never over 1;
- some reports mix the two inside one column: K441L9IN.OT0W prints psi
  '0.000' for counts of 1 to 3 in a dB table.  Carve-out
  mic-units-mixed accepts a mic field when every cell SFM disagrees
  with is SFM's own value in the other unit: 19 DL2 events (14 sample
  tables, 5 peaks); a cell matching neither stays a mismatch.

Not a decoder change: SFM's mic data were right.  Checker run
20261109-141808: 78 of 88 fields, 0 regressions; no mic peak or mic
sample table mismatches left.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-09 14:44:11 -05:00
1 parent e21d23a3f2
commit 0b6150adb5
9 files changed
+25513 -4

No files matched your search

BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
+39
View File
@@ -505,3 +505,42 @@ def test_a_range_1_mic_matches_blastware():
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
for f in ("MicLPSPL", "samples.MicL"):
assert res[f].verdict == "match", (f, res[f])
# ── The unit Blastware printed, field by field (2026-11-09) ─────────────────
# A report's event Units line does not always say what its mic values are in:
# 7 DL2 reports print the mic peak in dB under a psi line, 3 the reverse, and
# S353JTHU prints its sample table in dB under psi on both. The peak carries
# its own unit, and a mic table's cells are unmistakable (dB >= 60, psi < 1).
_UL = FIX.parent / "mic-units-11-09-26"
def _res(path, side=None):
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
return {r.field: r for r in compare(side or sfm_side(path.read_bytes()), ref, CARVEOUTS)}
@pytest.mark.parametrize("path,field", [
(_UL / "K441L9IN.OT0W", "MicLPSPL"), # psi line; the peak in dB, saying so
(_UL / "K888JOU7.8K0H", "MicLPSPL"), # the same on a histogram
])
def test_a_mic_peak_is_read_in_its_own_unit(path, field):
assert _res(path)[field].verdict == "match", _res(path)[field]
@pytest.mark.parametrize("path", [
_UL / "K441L9IN.OT0W", # a dB table with psi cells ("0.000", "-0.000") for counts of 1 to 3
_UL / "S353JTHU.DT0W", # psi rows, then dB rows, all under a psi line
])
def test_a_mic_column_mixing_dB_and_psi_is_accepted(path):
r = _res(path)["samples.MicL"]
assert (r.verdict, r.carveout) == ("accepted", "mic-units-mixed"), r
def test_the_mixed_units_carveout_needs_every_cell_in_one_unit_or_the_other():
path = _UL / "S353JTHU.DT0W"
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
i = ref.channels.index("MicL")
ref.sample_rows[0][i] = "50.00" # neither SFM's dB nor its psi
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
assert res["samples.MicL"].verdict == "mismatch"