feat(checker): read each mic value in the unit Blastware printed; carve out mixed columns
Blastware's dB(L) / psi(L) labels do not hold for the mic on every report (DL2, 2026-11-09): - the mic peak carries its own <Units>, which 7 reports set to dB under a psi Units line and 3 the reverse: the checker now reads the peak in its own unit; - a mic sample table has no unit of its own and need not follow the line (S353JTHU.DT0W prints dB under psi): the checker reads it from its cells -- a mic dB value is never under 60, psi never over 1; - some reports mix the two inside one column: K441L9IN.OT0W prints psi '0.000' for counts of 1 to 3 in a dB table. Carve-out mic-units-mixed accepts a mic field when every cell SFM disagrees with is SFM's own value in the other unit: 19 DL2 events (14 sample tables, 5 peaks); a cell matching neither stays a mismatch. Not a decoder change: SFM's mic data were right. Checker run 20261109-141808: 78 of 88 fields, 0 regressions; no mic peak or mic sample table mismatches left. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
1 parent
e21d23a3f2
commit
0b6150adb5
9 files changed
+25513
-4
Reference in new issue
Block a user