feat(checker): read each mic value in the unit Blastware printed; carve out mixed columns

Blastware's dB(L) / psi(L) labels do not hold for the mic on every
report (DL2, 2026-11-09):
- the mic peak carries its own <Units>, which 7 reports set to dB under
  a psi Units line and 3 the reverse: the checker now reads the peak in
  its own unit;
- a mic sample table has no unit of its own and need not follow the
  line (S353JTHU.DT0W prints dB under psi): the checker reads it from
  its cells -- a mic dB value is never under 60, psi never over 1;
- some reports mix the two inside one column: K441L9IN.OT0W prints psi
  '0.000' for counts of 1 to 3 in a dB table.  Carve-out
  mic-units-mixed accepts a mic field when every cell SFM disagrees
  with is SFM's own value in the other unit: 19 DL2 events (14 sample
  tables, 5 peaks); a cell matching neither stays a mismatch.

Not a decoder change: SFM's mic data were right.  Checker run
20261109-141808: 78 of 88 fields, 0 regressions; no mic peak or mic
sample table mismatches left.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-09 14:44:11 -05:00
1 parent e21d23a3f2
commit 0b6150adb5
9 files changed
+25513 -4

No files matched your search

+39
View File
@@ -505,3 +505,42 @@ def test_a_range_1_mic_matches_blastware():
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
for f in ("MicLPSPL", "samples.MicL"):
assert res[f].verdict == "match", (f, res[f])
# ── The unit Blastware printed, field by field (2026-11-09) ─────────────────
# A report's event Units line does not always say what its mic values are in:
# 7 DL2 reports print the mic peak in dB under a psi line, 3 the reverse, and
# S353JTHU prints its sample table in dB under psi on both. The peak carries
# its own unit, and a mic table's cells are unmistakable (dB >= 60, psi < 1).
_UL = FIX.parent / "mic-units-11-09-26"
def _res(path, side=None):
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
return {r.field: r for r in compare(side or sfm_side(path.read_bytes()), ref, CARVEOUTS)}
@pytest.mark.parametrize("path,field", [
(_UL / "K441L9IN.OT0W", "MicLPSPL"), # psi line; the peak in dB, saying so
(_UL / "K888JOU7.8K0H", "MicLPSPL"), # the same on a histogram
])
def test_a_mic_peak_is_read_in_its_own_unit(path, field):
assert _res(path)[field].verdict == "match", _res(path)[field]
@pytest.mark.parametrize("path", [
_UL / "K441L9IN.OT0W", # a dB table with psi cells ("0.000", "-0.000") for counts of 1 to 3
_UL / "S353JTHU.DT0W", # psi rows, then dB rows, all under a psi line
])
def test_a_mic_column_mixing_dB_and_psi_is_accepted(path):
r = _res(path)["samples.MicL"]
assert (r.verdict, r.carveout) == ("accepted", "mic-units-mixed"), r
def test_the_mixed_units_carveout_needs_every_cell_in_one_unit_or_the_other():
path = _UL / "S353JTHU.DT0W"
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
i = ref.channels.index("MicL")
ref.sample_rows[0][i] = "50.00" # neither SFM's dB nor its psi
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
assert res["samples.MicL"].verdict == "mismatch"