docs: phase 4 bench -- call-home on/off on both series, idle and monitoring

Benched 2026-11-03 on UM20147 and BE9441 (each on its own modem, one send per
go): idle, a no-op, off and on all acked, read back and confirmed on each unit's
menu; UM20147 accepts 0x00 at [5].  Monitoring, neither series takes a change: a
MiniMate answers 0x2C with its device-info block, a Micromate acks and ignores
('Feature disabled while monitoring').  Series 4 [118:120] is a function of the
block's content -- XOR 0x6D7D per bit-0 flip on two units, not a nonce.  A stop's
call-in reached THOR when the ring followed the ack.  UM20147's clock is an hour
ahead (DST).  Spec, both protocol references (Series III: a CRLF row), CLAUDE.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 15:32:51 -05:00
1 parent 789e24be50
commit 2e1c2ba21f
4 files changed
+63 -6

No files matched your search

@@ -576,10 +576,23 @@ Each safety piece arrives with its first real use, so nothing sits untested.
16:02-16:04 call-in time would have been refused as 'sent' or sent shifted --
fixed with a test through the real protocol (`bdd76b8`), plus a pre-wire refusal
audited as nothing sent, an unknown Series-4 run state refused, and the snapshot
kept on a lost ack (`9e03b3f`). **Not yet at the bench.** Bench
questions, one send per go: does a Micromate accept a no-op call-home write
(`even_if_already`)? Does UM20147 accept `0x00` at `[5]` (THOR only ever wrote
`0x04`/`0x05`)? Does either series take a call-home write while monitoring?
kept on a lost ack (`9e03b3f`). **Benched 2026-11-03** (UM20147 and BE9441,
each on its own modem; one send per go):
- **Idle, both series:** a no-op, off, and on were each acked and read back,
and each unit's own menu agreed. UM20147 accepts `0x00` at `[5]`.
- **Monitoring, neither series can change call-home:**
- A MiniMate answers the `0x2C` read with its device-info block, so SFM
refuses with "stop monitoring first" (`5326e99`).
- A Micromate returns the real block and acks the write, but ignores it
("Feature disabled while monitoring" on its own menu). SFM now refuses
up front, and edits only a block whose header is its own length
(`f35845d`).
- **Series 4 `[118:120]`:** a function of the block's content (a fixed XOR of
`0x6D7D` per bit-0 flip, on two units).
- **Batch 1's #9 reconnect worked live:** BE9441's line dropped in the sensor
check, and the start was verified.
- Details: `docs/micromate_protocol_reference.md` (Bench 2026-11-03) and the
Series-III reference's 2026-11-03 row.
5. **Setup push** (row 10): one field first, then several.
Each phase is its own implementation plan. **All phases land on