From 3215c17e3701e5600e66785d592a1395a574bec2 Mon Sep 17 00:00:00 2001 From: serversdown Date: Tue, 20 Oct 2026 18:33:48 -0400 Subject: [PATCH] docs(spec): one user experience for both series -- the guiding principle, applied Brian's principle: talking to a Series 3 or a Series 4 unit is identical for the user; only the serial prefix and each model's settings differ, and the adapters absorb the rest. Five places the draft broke it, now fixed: units are named the same way (serial + address, no-serial kept only as a legacy Series-3 path); one set of series-neutral response models with series-only fields under `detail`; one opaque event_id for both; a uniform 501 "not supported for Series N yet" instead of missing routes; and the webapp brought into scope with the same screens for both. Adds an adapter table, contract tests that keep the two adapters honest, and notes that existing Series-3 response shapes move to the shared models (the webapp updates with them; Terra-View does not call /device/*). Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44 --- .../2026-10-20-sfm-series4-parity-design.md | 91 +++++++++++++++---- 1 file changed, 75 insertions(+), 16 deletions(-) diff --git a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md index 0cbf114..5d7bb20 100644 --- a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md +++ b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md @@ -19,6 +19,12 @@ only speak Series 3. This design does three things: the serial, and keeps the connection open for later commands instead of reconnecting each time. +**The guiding principle (Brian): talking to a Series 3 unit and talking to a +Series 4 unit is the same for the user.** It is the same screens, the same +endpoints, the same way of naming a unit, and the same shape of answer. The +only visible difference is the serial (`UM…` vs `BE…`) and the settings each +model has. The differences live underneath, in one adapter per series. + It does **not** cover the emergency tools (runaway-unit stops, rescue, erase), the call-home receiver, or anything async. Those come later, as features shared by both series. @@ -34,6 +40,7 @@ Series-4 SFM is for the bench and for units THOR is not holding. | decision | why | who | |---|---|---| +| **One user experience for both series** | the user's method is identical; only the serial prefix and each model's settings differ; adapters absorb the rest | Brian | | Match **jobs**, not endpoints | some Series-3 endpoints only exist to work around Series-3 quirks | agreed | | **No Series-4 emergency tools** yet (runaway stop, rescue, erase) | Micromates rarely need them | Brian | | The series comes from the **serial prefix**: `UM` = Micromate, `BE` = MiniMate Plus, `BA` = Blastmate | the prefixes are definitive, so there is no probing | Brian | @@ -55,8 +62,8 @@ of scope by decision. | 1 | Identify a unit | `/device/info` (walks the whole chain, slow) | implemented: `connect()` | dispatch to the Micromate client | | 2 | Quick status (monitoring, battery, memory, clock) | `monitor/status`, `storage_range`, `events/index` | implemented: `get_state()`; the `0x06` event count is decoded only in the bench tool | same endpoints; move the count decode into the client | | 3 | Read settings | compliance in `/device/info`; `GET /device/call_home` | `get_setup()` implemented and verified on hardware; call-home: enable + dial string observed, rest unmapped | setup in full; call-home returns enable + dial string + raw | -| 4 | List events | `/device/events` (downloads every event to list them) | implemented, and cheap: the chain walk returns sizes | dispatch | -| 5 | Download an event | `/event/{i}`, `/waveform`, `/blastware_file` | implemented: streams the `.IDFW`/`.IDFH` itself, with a decode self-check | save through the existing `/db/import/idf_file` path | +| 4 | List events | `/device/events` (downloads every event to list them) | implemented, and cheap: the chain walk returns sizes | the same event-list shape as Series 3, each event carrying an `event_id` | +| 5 | Download an event | `/event/{i}`, `/waveform`, `/blastware_file` | implemented: streams the `.IDFW`/`.IDFH` itself, with a decode self-check | the same download and save-to-DB actions as Series 3. Underneath, Series 4 saves through `/db/import/idf_file` | | 6 | Monitor log | only via `ach_server` (broken, see the fix list) | `0x0A` read exists; no wrapper or decoder | client wrapper + partial decode | | 7 | Start / stop monitoring | `monitor/start`, `monitor/stop` | mapped, identical to Series 3 (`0x96`/`0x97`, acks `0x69`/`0x68`); never sent | **first write.** Verify with `0x49` state | | 9 | Change call-home settings | `POST /device/call_home` | write mapped (`0x2C` → `0x7E`/`0x7F`, same as Series 3); field map mostly unknown | enable/disable only; the rest waits for the THOR round | @@ -84,18 +91,61 @@ device_access ── series from serial prefix ── session / per-unit lock read-back verification (changes only) ``` -- **Series selection.** `serial` picks the library: `UM` → `micromate`; `BE` - or `BA` → `minimateplus`; any other prefix → 422. With no `serial`, the - request is Series 3, so existing Series-3 callers are unchanged. - **Series-4 requests must include `serial`.** -- **Endpoints.** The same `/device/*` paths, plus a `serial` query parameter. - Responses gain `"series": 3 | 4`. Where the two series genuinely differ (the - setup fields, the event identity), the body is series-specific under a - documented shape rather than forced into Series 3's. +- **Naming a unit is the same for both: `serial` + address.** The prefix picks + the adapter: `UM` → Series 4 (`micromate`); `BE` or `BA` → Series 3 + (`minimateplus`); any other prefix → 422. A request with no `serial` is + treated as Series 3. That is a **legacy path** kept only so existing scripts + keep working; the webapp and every new caller always send `serial`. +- **One contract.** Same `/device/*` paths, same request parameters, and + **the same response models for both series**: + - `UnitInfo`, `UnitStatus`, `UnitSettings`, `EventRef`, `ChangeResult` + - Anything only one series has goes under a `detail` object inside the same + model, never as a different top-level shape. `"series": 3 | 4` is + informational. +- **Events have one identity.** An opaque `event_id` string from the event + list, passed back to download it. Underneath it is Series 3's position or + Series 4's device key, plus the serial; the user never handles either. +- **Not-yet-supported is uniform.** If one series can't do something yet, + the endpoint still exists and answers **501 "not supported for Series N + yet"**. It is never a missing route or a different call. - **Work separate from HTTP.** Each operation is a plain function taking the session. The handler is a thin wrapper, so making an operation an async job later means changing the wrapper, not the operation. +### Adapters + +Each series implements the same operation set behind `device_access`: + +| operation | Series 3 adapter | Series 4 adapter | +|---|---|---| +| `identify` | STARTUP + serial + config | `connect()` | +| `status` | `0x1C` (+ `0x06`) | `get_state()` + `0x06` count | +| `read_settings` | `0x1A` compliance decode | `get_setup()` | +| `list_events` | today's walk | chain walk (cheap) | +| `download_event` | 5A → Blastware file | 5A → `.IDFW`/`.IDFH` | +| `monitor_log` | 501 for now (`ach_server` path is broken) | `0x0A` wrapper | +| `start` / `stop` | `0x96` / `0x97` (exists) | `0x96` / `0x97` (new) | +| `read_call_home` / `set_call_home_enabled` | exists | `0x2C` / `0x7E`+`0x7F` | +| `push_settings` | `/device/config` path (exists) | setup push (new) | +| `call_up` / `hang_up` | connect-per-request underneath, until the bench test | held session | + +Each adapter maps its native data into the shared models. `UnitSettings` keeps +the fields both series have under the same names and units: record mode, +sample rate, record time, histogram interval, trigger levels, the notes as +label → value. Model-specific fields go under `detail`. + +**Existing Series-3 response shapes change to the shared models.** The webapp +is updated in the same phase; Terra-View does not call `/device/*`. The +emergency endpoints (`stop_monitoring_*`, `rescue`, `events/erase`) are not +touched and stay Series-3 only; a `UM` serial gets 501. + +### The webapp + +The same screens for both series. You name a unit by serial + address (today +it takes host/port only), and the series shows as a badge, nothing more. Read +panels for both series land in phase 1; each write button appears for Series 4 +in the phase that adds that write. + ### The safety layer **Tiers.** Every operation declares one: @@ -161,7 +211,7 @@ One row per change attempt: Reads are not audited. -### Sessions (Series 4) +### Sessions 1. **Call up.** Connect, `connect()` (POLL / SERIAL / STATE), identity check against the requested serial. @@ -176,8 +226,9 @@ Reads are not audited. retry should reach THOR. 🔶 *Inferred:* the unit retries; its `0x2C` retries field reads 3. -Series 3 keeps today's connect-per-request behaviour until the bench test -under *Testing*. +**Call up and hang up are the same for both series.** Underneath, the +Series-3 adapter keeps today's connect-per-request behaviour until the bench +test under *Testing*; the user sees the same actions either way. ### Series-4 write path @@ -243,6 +294,11 @@ reviewed this way first. - RADIO RING → session ends - **Endpoints** through FastAPI's `TestClient` against the scripted transport already used in `tests/test_micromate_client.py`. +- **Contract tests.** The same test, run against both adapters with fakes, + asserts that each job returns the same model with the same field names and + units. A field present for one series and absent for the other is a test + failure unless it lives under `detail`. This is the test that keeps the + guiding principle true as the code grows. **Bench (UM20147, with Brian):** each write's first live send follows the same protocol: @@ -267,9 +323,12 @@ session open to a MiniMate that is monitoring, for several minutes. Record: Each safety piece arrives with its first real use, so nothing sits untested. -1. **Series-4 reads in SFM.** `device_access.py`, series selection, the - per-unit lock (Series 3 too), the error mapping, and Series-4 sessions with - ring safety. Rows 1–6. **No writes.** +1. **One contract, reads only.** `device_access.py`, the two adapters, the + shared models, series selection, the per-unit lock, the error mapping, and + sessions with ring safety. Rows 1–6 for **both** series through the same + endpoints. **No writes.** + - 1b. **The webapp:** serial + address, and the same read panels for both + series. 2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still nothing sent. 3. **Start/stop monitoring** (row 7): the first live write, at the bench.