feat(webapp): start/stop through the audited serial path, with the honest result
- With a serial, Start / Stop ask first ("Start monitoring on BE9441?"), then
POST once to the audited change -- never retried; both buttons stay off while
it is in flight, so a double click cannot send twice.
- The status bar shows changeSummary() of the ChangeResult, on a 409/502 too
(dry run, already-in-state, confirmed a -> b, or the outcome and read-back);
an error without one shows its detail verbatim; no reply from SFM says the
command may have been sent and where to look, rather than that nothing was.
- Then one status read updates the panel. The legacy 5 s confirm poll is not
used in serial mode; with a blank serial start/stop are unchanged.
- Diagnostics' Stop, which goes the same way in serial mode, shows the same
summary; deviceFetch errors carry it for any non-200 ChangeResult.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
9aae3b09de
commit
3f249e2322
1 file changed
+40
-4
+40
-4
@@ -1664,7 +1664,8 @@ async function deviceFetch(action, params = {}, opts = {}) {
|
|||||||
const body = await r.json().catch(() => ({}));
|
const body = await r.json().catch(() => ({}));
|
||||||
if (!r.ok) {
|
if (!r.ok) {
|
||||||
const d = body.detail;
|
const d = body.detail;
|
||||||
const err = new Error(typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : r.statusText);
|
const err = new Error(body.outcome ? changeSummary(body)
|
||||||
|
: typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : r.statusText);
|
||||||
err.status = r.status; err.body = body;
|
err.status = r.status; err.body = body;
|
||||||
throw err;
|
throw err;
|
||||||
}
|
}
|
||||||
@@ -1908,14 +1909,17 @@ function updateMonitorPanel(s) {
|
|||||||
// Start/stop: in serial mode only for a unit whose series its own answer
|
// Start/stop: in serial mode only for a unit whose series its own answer
|
||||||
// confirmed; without a serial, as before (0x96/0x97 mean the same on both).
|
// confirmed; without a serial, as before (0x96/0x97 mean the same on both).
|
||||||
let lastMonitoring = null;
|
let lastMonitoring = null;
|
||||||
|
let changeInFlight = false; // one start/stop at a time: a double click must not send twice
|
||||||
function setMonitorButtons() {
|
function setMonitorButtons() {
|
||||||
const allowed = serialMode() ? controlsFor(currentUnit()).startStop : Boolean(devHost());
|
const allowed = !changeInFlight
|
||||||
|
&& (serialMode() ? controlsFor(currentUnit()).startStop : Boolean(devHost()));
|
||||||
document.getElementById('mon-start-btn').disabled = !allowed || lastMonitoring === true;
|
document.getElementById('mon-start-btn').disabled = !allowed || lastMonitoring === true;
|
||||||
document.getElementById('mon-stop-btn').disabled = !allowed || lastMonitoring === false;
|
document.getElementById('mon-stop-btn').disabled = !allowed || lastMonitoring === false;
|
||||||
}
|
}
|
||||||
|
|
||||||
async function startMonitoring() {
|
async function startMonitoring() {
|
||||||
if (!devHost()) return;
|
if (!devHost()) return;
|
||||||
|
if (serialMode()) { await changeMonitoring('start'); return; }
|
||||||
const btn = document.getElementById('mon-start-btn');
|
const btn = document.getElementById('mon-start-btn');
|
||||||
btn.disabled = true; btn.textContent = '…';
|
btn.disabled = true; btn.textContent = '…';
|
||||||
setStatus('Starting monitoring…', 'loading');
|
setStatus('Starting monitoring…', 'loading');
|
||||||
@@ -1966,6 +1970,7 @@ async function _pollMonitorConfirm(attempt) {
|
|||||||
|
|
||||||
async function stopMonitoring() {
|
async function stopMonitoring() {
|
||||||
if (!devHost()) return;
|
if (!devHost()) return;
|
||||||
|
if (serialMode()) { await changeMonitoring('stop'); return; }
|
||||||
const btn = document.getElementById('mon-stop-btn');
|
const btn = document.getElementById('mon-stop-btn');
|
||||||
btn.disabled = true; btn.textContent = '…';
|
btn.disabled = true; btn.textContent = '…';
|
||||||
setStatus('Stopping monitoring…', 'loading');
|
setStatus('Stopping monitoring…', 'loading');
|
||||||
@@ -1980,6 +1985,37 @@ async function stopMonitoring() {
|
|||||||
btn.textContent = '■ Stop';
|
btn.textContent = '■ Stop';
|
||||||
}
|
}
|
||||||
|
|
||||||
|
// Serial mode: SFM's audited change -- identity and state read first, one send,
|
||||||
|
// never retried, then read back. The result body says what the unit did, on a
|
||||||
|
// 409/502 too; only the read that follows decides the panel.
|
||||||
|
async function changeMonitoring(action) {
|
||||||
|
const serial = normSerial(currentUnit().serial);
|
||||||
|
const verb = action === 'start' ? 'Start' : 'Stop';
|
||||||
|
if (!confirm(`${verb} monitoring on ${serial}?`)) return;
|
||||||
|
const btn = document.getElementById(action === 'start' ? 'mon-start-btn' : 'mon-stop-btn');
|
||||||
|
const label = btn.textContent;
|
||||||
|
changeInFlight = true; setMonitorButtons(); btn.textContent = '…';
|
||||||
|
setStatus(action === 'start' ? 'Starting — the unit runs its sensor check first (about 35 s)'
|
||||||
|
: 'Stopping…', 'loading');
|
||||||
|
try {
|
||||||
|
const r = await deviceRequest(action);
|
||||||
|
const body = await r.json().catch(() => ({}));
|
||||||
|
if (body.outcome) {
|
||||||
|
setStatus(changeSummary(body), r.ok ? 'ok' : 'error');
|
||||||
|
} else {
|
||||||
|
const d = body.detail;
|
||||||
|
setStatus(`${verb} monitoring failed: ${typeof d === 'string' ? d : d ? JSON.stringify(d) : r.statusText}`, 'error');
|
||||||
|
}
|
||||||
|
} catch (e) {
|
||||||
|
// No reply is not "nothing sent": the request may have reached the unit.
|
||||||
|
setStatus(`${verb} monitoring: no reply from SFM (${e.message}) — it may have been sent; `
|
||||||
|
+ `check the unit's state and GET /db/device_commands`, 'error');
|
||||||
|
}
|
||||||
|
changeInFlight = false; btn.textContent = label;
|
||||||
|
await refreshMonitorStatus();
|
||||||
|
setMonitorButtons();
|
||||||
|
}
|
||||||
|
|
||||||
// ── Device tab ─────────────────────────────────────────────────────────────────
|
// ── Device tab ─────────────────────────────────────────────────────────────────
|
||||||
function populateDeviceTab() {
|
function populateDeviceTab() {
|
||||||
document.getElementById('no-device-msg').style.display = 'none';
|
document.getElementById('no-device-msg').style.display = 'none';
|
||||||
@@ -2126,8 +2162,8 @@ async function diagStopMonitoring() {
|
|||||||
const btn = document.getElementById('diag-stop-btn');
|
const btn = document.getElementById('diag-stop-btn');
|
||||||
btn.disabled = true; diagResult('diag-stop-result', 'Sending…');
|
btn.disabled = true; diagResult('diag-stop-result', 'Sending…');
|
||||||
try {
|
try {
|
||||||
await deviceFetch('stop');
|
const r = await deviceFetch('stop');
|
||||||
diagResult('diag-stop-result', 'Stop acknowledged — recording halted.', 'ok');
|
diagResult('diag-stop-result', r.outcome ? changeSummary(r) : 'Stop acknowledged — recording halted.', 'ok');
|
||||||
refreshDiagnostics();
|
refreshDiagnostics();
|
||||||
} catch (e) {
|
} catch (e) {
|
||||||
diagResult('diag-stop-result', `Failed: ${e.message}`, 'error');
|
diagResult('diag-stop-result', `Failed: ${e.message}`, 'error');
|
||||||
|
|||||||
Reference in new issue