test+docs: SFM's MiniMate downloads are byte-identical to Blastware's; the 64 KB bug narrowed
Brian's Blastware downloads of BE9441's 20 events give ground truth. SFM's re-run downloads of events 0, 1, 3, 4 and 10 are byte-identical to Blastware's own files; imported first through the watcher route, the same events download as already_stored (no duplicate rows -- the unit's 0C and Blastware's file agree on serial + timestamp). Fixtures: Blastware's P00/Q10 (now asserted equal to SFM's builds) and QZ0/T80, the two page-crossing events, as byte-exact targets. The 64 KB page bug, narrowed by a read-only test walk: carrying the page byte addresses the first chunk in page 0x12 (answered), but the next request carries a raw 0x03 inside its params (counter 0x032c) and gets no reply. Pages after 0x11 have such counters; 0x11 does not (event 1 skips 0x0000-0x05FF). Needs a Blastware wire capture of event 2 or 19 (recorded in CLAUDE.md, the Series-III reference and the spec). No code change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
1ded70fcd9
commit
465bc704dd
9 files changed
+49
-1
No files matched your search
@@ -262,6 +262,19 @@ Read this first when picking the project back up.
|
||||
over) needs a BW capture of a spanning event first. Do not ship layer one
|
||||
alone without a loud truncation warning — a silently short event is the
|
||||
failure mode this codec has been bitten by repeatedly.
|
||||
**Narrowed 2026-10-26 (BE9441, measured):**
|
||||
- The one-event download now refuses a spanning event by name (502), before
|
||||
any chunk.
|
||||
- STRT carries the full 32-bit end key, so the page is there to use.
|
||||
- A read-only test walk carrying the page byte got a proper reply for the
|
||||
first chunk in the next page (`01 12 01 2c`). The second chunk, params
|
||||
`… 01 12 03 2c`, got none: a raw `0x03` inside the params.
|
||||
- Pages after `0x11` have counters with `02`/`03`/`04` bytes. Page `0x11`
|
||||
has none, because event 1 skips `0x0000`–`0x05FF`.
|
||||
- How Blastware encodes those bytes is the one unknown left. The capture to
|
||||
take: Blastware downloading BE9441 event 2 (`0111c92c`) or 19 (`0118a4ca`)
|
||||
through the recording bridge. Blastware's own files for both are fixtures
|
||||
(`tests/fixtures/minimate-bench-10-25-26/blastware/`), as byte-exact targets.
|
||||
- **Open, not blocking:** 14 sensitive-range files show an exact 8x
|
||||
(= 10.0/1.25) units discrepancy; `scripts/backfill_sidecars.py --force` also
|
||||
inserts DB rows for store files that have none (one-time per store) and the
|
||||
|
||||