test+docs: SFM's MiniMate downloads are byte-identical to Blastware's; the 64 KB bug narrowed

Brian's Blastware downloads of BE9441's 20 events give ground truth.  SFM's
re-run downloads of events 0, 1, 3, 4 and 10 are byte-identical to Blastware's
own files; imported first through the watcher route, the same events download
as already_stored (no duplicate rows -- the unit's 0C and Blastware's file agree
on serial + timestamp).  Fixtures: Blastware's P00/Q10 (now asserted equal to
SFM's builds) and QZ0/T80, the two page-crossing events, as byte-exact targets.

The 64 KB page bug, narrowed by a read-only test walk: carrying the page byte
addresses the first chunk in page 0x12 (answered), but the next request carries
a raw 0x03 inside its params (counter 0x032c) and gets no reply.  Pages after
0x11 have such counters; 0x11 does not (event 1 skips 0x0000-0x05FF).  Needs a
Blastware wire capture of event 2 or 19 (recorded in CLAUDE.md, the Series-III
reference and the spec).  No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-26 12:15:50 -04:00
1 parent 1ded70fcd9
commit 465bc704dd
9 files changed
+49 -1

No files matched your search

+1
View File
@@ -11,6 +11,7 @@
| Date | Section | Change |
|---|---|---|
| 2026-10-26 (2) | §7.8 | **The 64 KB page bug, narrowed (measured, BE9441).** Blastware's own downloads of all 20 events (Brian, `example-events/10-25-26 - thumps`) give byte-exact ground truth. SFM's downloads of events 0, 1, 3, 4 and 10 are **byte-identical** to Blastware's. Importing Blastware's files first (the watcher route) makes SFM's downloads of the same events return `already_stored`: the unit's 0C and Blastware's file agree on (serial, timestamp). For an event that crosses a page (event 2, `0111c92c` → STRT end key `01122f06`, full 32 bits) a read-only test walk with the page byte carried (params `00 01 12 01 2c`) got a proper A5 reply for the first chunk in page 0x12, echoing `01 12 01 2c`. The second chunk, `00 01 12 03 2c`, got no reply frame: a raw 0x03 (ETX) inside the params. Page 0x11 never shows this, because event 1 skips 0x0000–0x05FF, so no counter there has a 02/03/04 byte. Every later page does. ⚠ How Blastware encodes a lone 02/03/04 inside params is unknown: §7.8 says `10 02/03/04` is kept as a literal pair, which would shift the address. A wire capture of Blastware downloading BE9441 event 2 or 19 settles it. Blastware's files are fixtures (`tests/fixtures/minimate-bench-10-25-26/blastware/`). |
| 2026-10-26 | §7.8 | **5A requests must DLE-escape a checksum that is a framing byte (measured, BE9441).** The request for chunk 0x7D06 of event 01122f06 ends `… 02 03`: a bare 0x02 checksum (STX) before ETX. BE9441 never answered it, twice on two days, and rebooted ~11 s later each time; that was the 'mid-download reboot' of 2026-10-25 (row below). Sent as `… 10 02 03` it answered in 28 ms. So did chunk 0x7F06 (checksum 0x04 → `10 04`) and 0x8B06 (checksum 0x10 → `10 10`; sent bare, that reads as DLE+ETX), and the event downloaded whole and matched the unit's peaks. Escape set {02, 03, 04, 10}: a Micromate's for every byte (251/251 THOR requests), and consistent with §7.8's de-stuffing rule (`10 02/03/04` literal). About 1 chunk request in 64 has such a checksum. ⚠ Not known: whether standard (non-5A) requests need the same. No such keyed-read checksum has been sent. Also measured on the re-run: events that end in the next 64 KB page (BE9441 events 2 and 19) read an end offset lower than their start (the known page bug); every other event downloaded whole and verified. |
| 2026-10-25 | §7.2, §7.8, §6 | **MiniMate bench check, BE9441 (S338.17, mic disabled, serial cable). SFM read its 24-entry event index, listed 20 events, and downloaded 4.** Measured: (1) **§7.2: the 0x15 serial is a C string.** `"BE9441\x00?"`: a six-character serial leaves a stray byte after its NUL. (2) **§7.8: every A5 reply echoes the address it answers at `data[2:6]`.** The metadata pages come back as `01 11 10 02` and `01 11 10 04`; sample chunks as their own address, e.g. `01 11 66 6a`. The event-1 walk fetches the metadata pages as frames 1 and 2. A non-first event's walk fetches none and goes straight from the probe to sample chunks. SFM's body builder assumed metadata pages in every stream, so every non-first event it assembled was 2 bytes short and decoded truncated; it now checks the echoed addresses. The bug was in SFM's assembly; the protocol was as already documented. (3) **§6: the unit boots when its serial port opens.** It sent `Operating System` ~3 s after the port opened (twice) and ignored a POLL sent before that. After a mid-download reboot it answered 8.8 s after its banner (one data point). (4) **The unit rebooted once mid-download.** The chunk at 0x7D06 got one stray `0x41`, then silence, then the banner 11 s later. Cause unknown, inferred not measured: battery 6.33–6.37 V, a firmware reset. ⚠ **RETRACTED 2026-10-26:** the cause is measured, and it was our request. The chunk request had a bare 0x02 checksum. See the 2026-10-26 row. (5) The event index said 24 while the header walk listed 20 full records. **Inferred:** the other 4 are monitor-log entries. Single-shot events at 4096 sps with a 5 s record give **21,504 samples per channel** (5 s record + 0.25 s pre-trigger = 5.25 s at 4096 sps), all three channels equal, peaks equal to the unit's own 0C values. |
| 2026-10-17 | §7.6.1 | 🔶 **OPEN — the 6-byte "stable anchor" may be two settings at their defaults, not a constant.** Series IV's `0x1A` has the same field order as the S3 compliance block, and a keypad diff pass on a Micromate (UM20147) measured the bytes in the anchor's position: `[f32 BE pre-trigger, negative seconds][record stop mode, 00 00 = Fixed]`. `be 80 00 00` is exactly −0.25 s. If S3 matches — **inferred, not measured on S3** — then any S3 unit set to Record Stop Mode = Auto (a basic Blastware Compliance Setup option) or a non-default pre-trigger loses the anchor, and `client.py` silently decodes no recording mode / sample rate / interval / record time and skips them on write. No S3 capture has ever been taken in Auto stop mode (see the 2026-03-09 Auto Window rows), which would explain why the anchor never broke. To settle: one BW capture with Record Stop Mode = Auto. See `docs/micromate_protocol_reference.md` → *The `0x1A` field map from a keypad pass*. |