From 4b911b1c0c7474f6ee7de0cdd5cf4b03a82a4d16 Mon Sep 17 00:00:00 2001 From: serversdown Date: Sun, 25 Oct 2026 15:56:18 -0400 Subject: [PATCH] docs: the first commands this project originated -- start/stop on UM20147 Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back monitoring at the first 2 s poll (during the sensor check); 0x97 acked in 116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's call-home attempts after a stop) before idle; two stops to an idle unit acked in 10 ms and changed nothing. Retracts "no command has ever been originated" in place in CLAUDE.md and the reference's untested list; answers the spec's stop-while-stopped question. Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44 --- CLAUDE.md | 21 +++- docs/micromate_protocol_reference.md | 114 +++++++++++++++++- .../2026-10-20-sfm-series4-parity-design.md | 7 ++ 3 files changed, 135 insertions(+), 7 deletions(-) diff --git a/CLAUDE.md b/CLAUDE.md index eefb656..bf64cd7 100644 --- a/CLAUDE.md +++ b/CLAUDE.md @@ -10,7 +10,7 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as --- -## Where things stand (updated 2026-10-19) +## Where things stand (updated 2026-10-25) Read this first when picking the project back up. @@ -24,9 +24,15 @@ Read this first when picking the project back up. by 47x). Read path, event chain, setups, scheduler, monitoring control and per-event delete are all mapped — **and as of 2026-10-14 so is the inbound call-home session.** There are no protocol unknowns left. - ⚠ **No command has ever been originated against a unit by this project.** + ~~⚠ **No command has ever been originated against a unit by this project.** Every write was performed by THOR while we recorded. That line is worth - keeping. + keeping.~~ **Retracted 2026-10-25:** the first commands this project + originated were `0x96` / `0x97` (start / stop monitoring) to **UM20147 on + 2026-10-25**, sent by SFM at the bench with Brian's go for each send — 4 + sends, each acked and read back, each audited. Every *other* write + (call-home, setup push, delete, scheduler) is still THOR-only, never sent by + us. Details: `docs/micromate_protocol_reference.md` → *The first commands + this project originated*. **Series-4 write path, phase 2 is done (2026-10-22):** the write encoder, a send-side opcode gate and write *plans* for start/stop, call-home enable and the setup rewrite, reproduced byte for byte against THOR's captured frames. @@ -123,8 +129,13 @@ Read this first when picking the project back up. 5 events, a waveform that verified, a histogram, one call-up for the whole sequence. ⚠ The MiniMate header walk is **unproven on a unit; a MiniMate bench check is owed before the branch merges.** Next: 1c (webapp). -- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built and - reviewed offline; the first live send is pending at the bench.** Both +- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built, + reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in + 0.46 s and read back as monitoring at the first 2 s poll (during the sensor + check); stop acked in 0.12 s, then `0x49` read a new value **`0x01` for ~18 s** + (inferred: the unit's call-home attempts after a stop — refused as unmeasured + until settled) before idle; a stop while idle is a harmless 10 ms no-op. The + Series-3 path is unproven on a unit (MiniMate bench check owed). Both series go through one safety core, `sfm/device_access/change.py`: a fresh identity read, the run state (calling home or never measured is refused), `dry_run` (the exact frames, nothing sent), a row in the new diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 27b438e..fb61439 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2217,6 +2217,13 @@ having: nothing else read so far reports the unit's own time. ↑ data[11]: 0x02 monitoring, 0x00 idle ``` +> **Amended 2026-10-25.** There are four values now. `0x03` is a call-home +> session; see *Correction: `SUB 0x49` has a third state value*. `0x01` reads +> for about 18 s after a stop; its meaning is inferred to be a call-home attempt +> that has not connected. See *The first commands this project originated*. +> `0x02` was also read 2.5 s after a start, while the screen showed the sensor +> check. + **A second monitoring indicator, in a 21-byte response instead of `0x1C`'s 60.** Different encoding from `0x1C`'s flag (`0x02` vs `0x0E`), so they are separate fields, not the same byte read twice. For a polling client this is the cheaper @@ -4165,8 +4172,108 @@ assumed: device will not stop it and the ack will not distinguish it. That guard has to live in SFM. +## ✅ The first commands this project originated: start and stop on UM20147 (2026-10-25) + +These were the first frames this project ever sent to a unit that change its +state. Every write before this one was THOR's, recorded while we watched. Brian +gave a go at the bench for each send. + +**Setup.** +- **Unit:** UM20147, firmware `11.0BD` (Thor line, reply flags `0x03`), on USB + CDC-ACM `/dev/ttyACM0`. +- **Sensors:** none attached. +- **Active setup:** `BENCH01`. +- **Sender:** SFM's `POST /device/monitor/start|stop?serial=UM20147` (branch + `feat/series4-sfm-parity` at `b1c87ec`), with every TX frame and every + validated RX frame logged at millisecond resolution. +- **Path:** each send went through the phase-3 safety core in this order: + 1. a fresh serial read; + 2. a `0x49` state read; + 3. the audit row written; + 4. one `execute()`; + 5. read back every 2 s. + +### What was sent and what came back (measured) + +| time (EDT) | sent | ack | ack latency | `0x49` content[0] afterwards | +|---|---|---|---|---| +| 15:43:47.430 | `0x96` `41021010009600ffff00000000000000000000a403` | `0x69`, 11 zero bytes | **464 ms** | `0x02` at the first read, 2.0 s after the ack | +| 15:45:51.922 | `0x97` `41021010009700ffff00000000000000000000a503` | `0x68`, 11 zero bytes | **116 ms** | **`0x01` on all 9 reads from +2.1 s to +18.2 s**, then `0x00` from +20.3 s | +| 15:52:42.645 | `0x97` (unit already idle; `even_if_already`) | `0x68`, 11 zero bytes | **10 ms** | `0x00`, unchanged | +| 15:53:51.871 | `0x97` (idle again, screen watched) | `0x68`, 11 zero bytes | **10 ms** | `0x00`, unchanged | + +- **The frames.** Both are THOR's own bytes, offset `0xFFFF` included. The phase-2 + bench question "is offset `0x0000` honoured" was not tested and does not need + to be. +- **`0x1C` `data[12]` agrees.** It read `0x00` idle before the start, `0x0E` at + the start's read-back and at the stop's preamble, and `0x00` again at +20 s. + `0x0E` is the same monitoring value UM12947 showed on 2026-09-24. `0x1C` was + not read during the `0x01` window. +- **The start's screen** showed a sensor check, then monitoring. With no sensors + attached, the check passed without complaint (Brian, watching). +- **The start's state.** `0x49` already read `0x02` at +2.5 s, so the state + byte very probably reads monitoring *during* the sensor check. That is + inferred, not measured: the check's length on screen was not timed. + Consequence: a second start sent during the check would see "monitoring" and + be skipped, not sent. +- **One histogram was recorded and closed.** The event is timestamped + 15:44:01, 14 s after the start, which is roughly the length of the sensor + check. The event count went 5 → 6 at the stop (`UM20147_20261025154401.IDFH`, + 7,976 B). + - Its peaks are 0.00186 in/s on all three channels, identical, because no + sensors were attached. + - Free memory fell 4,096 B at the start and another 4,096 B by the stop. The + same 4 KiB step was seen in the 2026-09-24 session. +- **The stop's screen.** The unit tried to call home right after the stop. Brian + says it always does this when taken out of monitor mode. It never connected, + because it has no modem, and it ran out of attempts. A watch of `0x49` + once a second from 15:47:19 to 15:49:50 read `0x00` throughout. +- **A stop sent to an idle unit is harmless.** It was acked in 10 ms, twice. + Nothing changed: not the state, the event count, free memory or the screen, + and there was no call-home attempt. The ~10x shorter ack suggests the + firmware skips its close-down work. This settles the spec's open question + "what does a stop-while-stopped do". + +### 🔶 `0x49` content[0] = `0x01`: a fourth state value (value measured, meaning inferred) + +The values are now `0x00` idle, `0x02` monitoring and `0x03` in a call-home +session (10 of 10 reads, 2026-10-14). The new one is **`0x01`, for about 18 s +right after a stop**. + +**Inferred meaning: a call-home *attempt* in progress, dialling and not +connected.** It is distinct from `0x03`, a call-home *session* that has +connected. The timing fits: the `0x01` window opened 2 s after the stop, on +screen the unit was trying to call home, and it closed when the attempts ran +out. + +**Not excluded:** `0x01` could instead mean "stopping, closing the record", with +the call-home attempts overlapping it. Two tests would separate them: +- a stop with call-home-after-event switched off; +- a stop on a unit whose modem connects, where the inference predicts + `0x01` → `0x03`. This fits into the ring-path Run A/B. + +**What SFM does with it.** `read_run_state()` names it `unknown(0x01)`, so the +change path refuses any start or stop in that window ("never been measured -- +nothing sent", HTTP 409). That is deliberate: name it only once its meaning is +measured. The stop's read-back simply kept polling through it, because `0x01` +is not idle, and the stop verified at +20 s, well inside the 60 s window. + +### Audit rows (SFM `device_commands`, scratch bench DB) + +All four rows read `outcome=sent`, `verified=ok`, `sent=1`, caller +`bench-brian`. Their `states` columns: +- **start:** `idle → [idle, monitoring] → monitoring` +- **stop:** `monitoring → [monitoring, 9 × unknown(0x01), idle] → idle` +- **the two forced stops:** `idle → [idle, idle] → idle`, each carrying the note + that the read-back cannot show the send changed anything. + ## ⚠ Untested and unsafe-until-agreed +> ✅ **Retracted in part (2026-10-25):** the opening line below was true until +> 2026-10-25. Start and stop (`0x96` / `0x97`) have now been **originated by +> SFM** against UM20147. See *The first commands this project originated*. Every +> other item in this section remains never-sent. + **Nothing below has been sent to a unit by us, and nothing should be without an explicit decision.** @@ -4183,12 +4290,15 @@ is known; our encoder is unwritten and unproven. `0x55`. **Destructive.** Series III's `0xA3`/`0xA2` erase-all has *not* been seen on Series IV and may not exist - **Start / stop monitoring** (`0x96` / `0x97`) — observed via Thor 2026-09-24, - acks `0x69` / `0x68` + acks `0x69` / `0x68`. ✅ **Originated by SFM 2026-10-25** on UM20147 (4 sends, + all acked and verified) — no longer untested - **Scheduler enable** (`0x47`) — observed; `params[7]` semantics still unclear Every one of these is now *observed*. **None has ever been originated by us**, and that is the line that still matters: the wire format is known, our encoder is -unwritten and unproven. +unwritten and unproven. *(2026-10-25: true still of every item here except +start/stop, which SFM originated at the bench — see the retraction note at the +top of this section.)* - `0x1F` (advance event pointer) — non-destructive on Series III but it does move device state, so it is parked with the rest diff --git a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md index 875d3c0..c1cbfbd 100644 --- a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md +++ b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md @@ -677,6 +677,13 @@ Open questions: on its own, in which case SFM never sees a ring and THOR gets the call while SFM is still connected. - The ack for start/stop when the unit is already in that state. + ✅ **Answered for stop (2026-10-25, UM20147):** a stop sent to an idle unit + is acked `0x68` in 10 ms (twice) and changes nothing: not the state, the + events, memory or the screen. Start while already monitoring has not been + tried. Also measured at that bench: `0x49` reads `0x01` for ~18 s after a + real stop. Its meaning is inferred to be the unit's call-home attempts, and + Run A/B can settle it: the inference predicts `0x01` → `0x03` when the modem + connects. - The offset rule, and whether `0x68`/`0x82` are required, for the setup push. - Whether the device ever refuses a write while monitoring. Only THOR's policy has been seen.