diff --git a/minimateplus/protocol.py b/minimateplus/protocol.py index 65ebeb3..f70b62d 100644 --- a/minimateplus/protocol.py +++ b/minimateplus/protocol.py @@ -169,6 +169,17 @@ class ImageRefused(ValueError): """A write refused before any byte was sent: the image is not a whole block.""" +def is_call_home_block(raw: bytes) -> bool: + """Whether a 0x2C reply payload is the call-home block: it starts with its own + length N = 0x7C (00 7C DC on every read on record) and is N (or N + 2) bytes + unescaped. A MONITORING MiniMate answers the read with its device-info block + instead (00 00 00 08 'Instantel' ..., measured 2026-11-03 on BE9441), which + fails this.""" + image = unescape_reply(bytes(raw)) + n = DATA_LENGTHS[SUB_CALL_HOME] + return len(image) >= 3 and int.from_bytes(image[:2], "big") == n and len(image) in (n, n + 2) + + def call_home_enabled(raw: bytes) -> Optional[bool]: """The call-home switch of a `0x2C` reply payload, read UNESCAPED (an escaped byte before it would move the raw index -- bench finding #1's lesson): byte 5, diff --git a/sfm/device_access/s3.py b/sfm/device_access/s3.py index 2fd16ef..4e0cc63 100644 --- a/sfm/device_access/s3.py +++ b/sfm/device_access/s3.py @@ -13,12 +13,12 @@ from minimateplus.event_file_io import _GEO_INT16_FS from minimateplus.framing import build_bw_write_frame, unescape_reply from minimateplus.protocol import ( SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_START_MONITORING, SUB_STOP_MONITORING, - ImageRefused, call_home_enabled, call_home_image, write_image, + ImageRefused, call_home_enabled, call_home_image, is_call_home_block, write_image, ) from minimateplus.transport import TcpTransport from .errors import (DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent, - WrongUnit, translate) + UnitStateUnknown, WrongUnit, translate) from .change import call_home_change, monitoring_change, run_change from .events import iso_of, make_event_id, stamp_of from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress, @@ -39,6 +39,13 @@ S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use # writes (BE11529, 2026-04-20) byte for byte from the unit's own reads. S3_CALL_HOME_FRAME_VERIFIED = True +# Measured 2026-11-03 (BE9441): while monitoring, a MiniMate answers the 0x2C read +# with its device-info block, as it answers 1A -- its call-home settings cannot be +# read, so they cannot be changed (SFM writes back only a block it just read). +S3_CALL_HOME_WHILE_MONITORING = ("did not return its call-home settings -- a MiniMate answers the " + "call-home read with its device-info block while monitoring; " + "stop monitoring first, then change call-home") + # The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is # BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram, # confirmed at the unit (2026-10-26). Anything else is refused for a change. @@ -349,11 +356,14 @@ class Series3Adapter: client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S) raw = client.read_call_home_raw() image = unescape_reply(raw) + detail = {"byte5": f"0x{image[5]:02X}" if len(image) > 5 else None, + "block": bytes(raw).hex(), "serial_verified": False} + if not is_call_home_block(raw): + detail["reason"] = f"the unit {S3_CALL_HOME_WHILE_MONITORING}" + return CallHomeState(serial=serial, series=3, enabled=None, dial_string=None, detail=detail) dial = bytes(image[6:46]).split(b"\x00", 1)[0].decode("ascii", errors="replace") or None return CallHomeState(serial=serial, series=3, enabled=call_home_enabled(raw), - dial_string=dial, - detail={"byte5": f"0x{image[5]:02X}" if len(image) > 5 else None, - "block": bytes(raw).hex(), "serial_verified": False}) + dial_string=dial, detail=detail) return self._run(address, op) def change_call_home(self, address: UnitAddress, serial: str, *, enabled: bool, dry_run: bool, @@ -378,6 +388,8 @@ class Series3Adapter: def read_state() -> str: client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S) raw = client.read_call_home_raw() + if not is_call_home_block(raw): + raise UnitStateUnknown(f"{serial} {S3_CALL_HOME_WHILE_MONITORING} -- nothing sent") reads.append(raw) on = call_home_enabled(raw) if on is None: diff --git a/sfm/static/device_routing.js b/sfm/static/device_routing.js index e2f44a0..dcf3a02 100644 --- a/sfm/static/device_routing.js +++ b/sfm/static/device_routing.js @@ -204,8 +204,9 @@ function serialPanes(bySerial, settingsRead) { // enable byte never measured -- shown with the byte, never as On or Off. function callHomeRows(state) { const s = state || {}; + const d = s.detail || {}; const sw = s.enabled === true ? 'On' : s.enabled === false ? 'Off' - : `Unknown (byte 5 = ${(s.detail || {}).byte5 ?? '?'})`; + : d.reason || `Unknown (byte 5 = ${d.byte5 ?? '?'})`; return [['Call-home', sw], ['Dial string', s.dial_string || '—'], ['Series', s.series]]; } /* */ diff --git a/tests/test_s3_call_home.py b/tests/test_s3_call_home.py index c72c3c5..4612127 100644 --- a/tests/test_s3_call_home.py +++ b/tests/test_s3_call_home.py @@ -145,3 +145,37 @@ def test_a_pre_wire_refusal_is_recorded_as_nothing_sent(): ((_, row),) = audit.rows.items() assert (row["outcome"], row["sent"]) == ("failed", 0) assert row["error"].startswith("refused before sending") + + + +# Measured 2026-11-03 (BE9441): while monitoring, a MiniMate answers the 0x2C read +# with its DEVICE-INFO block ("Instantel", "MiniMate Plus", its serial), not its +# call-home block -- as it answers 1A. Idle again, it returns the call-home block. +# SFM says so plainly instead of "run state unknown(0x6E)". + +def device_info_shaped(serial=b"BE9441"): + """Shaped like BE9441's reply (its first bytes: 00 00 00 08 'Instantel').""" + block = b"\x00\x00\x00\x08Instantel".ljust(26, b"\x00") + b"MiniMate Plus".ljust(16, b"\x00") + serial + return block.ljust(126, b"\x00") + + +def test_a_call_home_block_is_told_from_the_device_info_block(): + from minimateplus.protocol import is_call_home_block + assert is_call_home_block(s3_call_home_raw()) is True + assert is_call_home_block(device_info_shaped()) is False + + +@pytest.mark.parametrize("dry_run", [True, False]) +def test_a_monitoring_minimate_is_told_to_stop_first_and_nothing_is_sent(dry_run): + fake = FakeMiniMateClient(call_home_raw=device_info_shaped()) + with pytest.raises(UnitStateUnknown) as e: + change(adapter(fake), enabled=True, dry_run=dry_run) + msg = str(e.value) + assert "monitoring" in msg and "stop" in msg and "nothing sent" in msg + assert e.value.http_status == 409 and fake.writes == [] + + +def test_the_call_home_state_of_a_monitoring_minimate_says_why(): + st = adapter(FakeMiniMateClient(call_home_raw=device_info_shaped())).call_home_state(TCP, "BE18193") + assert st.enabled is None + assert "monitoring" in st.detail["reason"] diff --git a/tests/test_webapp_device_routing.py b/tests/test_webapp_device_routing.py index 37e3578..2ea7ffd 100644 --- a/tests/test_webapp_device_routing.py +++ b/tests/test_webapp_device_routing.py @@ -327,3 +327,10 @@ def test_call_home_rows(): assert r[0] == [["Call-home", "On"], ["Dial string", "RADIO RING"], ["Series", 4]] assert r[1] == [["Call-home", "Off"], ["Dial string", "—"], ["Series", 3]] assert r[2][0] == ["Call-home", "Unknown (byte 5 = 0x07)"] + + + +def test_call_home_rows_say_why_a_switch_did_not_read(): + r = run(["callHomeRows", [{"enabled": None, "dial_string": None, "series": 3, + "detail": {"byte5": "0x6E", "reason": "not readable while monitoring -- stop it first"}}]]) + assert r[0][0] == ["Call-home", "not readable while monitoring -- stop it first"]