fix(decode): one MicL count is 0.25 Pa -- the mic psi was ~95x low
SFM converted mic counts to psi with a '~0.5 psi full-scale' guess (0.0125 / 32768 psi per count). Measured against 1,729,253 DL2 histogram intervals' 'MicL Peak' columns: one count is exactly 0.25 Pa. count x 0.25 Pa matches Blastware's psi(L) on every interval, and 20 log10(count x 0.25 Pa / 20 uPa) its dB(L) on all but 17 exact half-way cases. - event_file_io: _MIC_FS_PSI -> _MIC_PSI_PER_COUNT = 0.25 / 6894.757 (3.626e-5 psi per count, was 3.81e-7). The event's mic peak in psi, and with it the .h5 mic trace (event_hdf5 back-solves its scale from that peak), come right on events with no report. - waveform_codec.mic_count_to_db: the offset is 20 log10(0.25 / 20e-6) = 81.938, not 81.94 -- the old value missed 49 of those intervals at a rounding edge (count 119 printed 123.4, 81.94 gave 123.451). The decoded count was always right: count 16 on K441LTON.900 is Blastware's 106.0 dB. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
1 parent
dc42ae041a
commit
5644dbd5ad
5 files changed
+56
-18
No files matched your search
@@ -708,10 +708,12 @@ _GEO_INT16_FS = 32000.0
|
||||
# the Normal range (the same assumption as the samples above).
|
||||
_HIST_GEO_UNIT_INS = 16 * _GEO_NORMAL_FS_INS / _GEO_INT16_FS
|
||||
|
||||
# Microphone scale factor, psi per ADC count. Approximate — exact factor
|
||||
# depends on the geophone-vs-mic ADC scaling and the firmware reference.
|
||||
# We mark mic_psi as "computed approximate" in the sidecar.
|
||||
_MIC_FS_PSI = 0.0125 / _INT16_FS # ~0.5 psi full-scale assumption
|
||||
# Microphone scale factor, psi per MicL count: one count is 0.25 Pa
|
||||
# (waveform_codec.MIC_PA_PER_COUNT, measured against Blastware's psi(L) on
|
||||
# 1,729,253 DL2 intervals). It replaces a "~0.5 psi full-scale" guess,
|
||||
# 0.0125 / 32768, that read every mic peak ~95x low (2026-10-31).
|
||||
_PA_PER_PSI = 6894.757
|
||||
_MIC_PSI_PER_COUNT = _wc.MIC_PA_PER_COUNT / _PA_PER_PSI
|
||||
|
||||
|
||||
def _decode_strt(strt: bytes) -> dict:
|
||||
@@ -763,9 +765,9 @@ def _peaks_from_samples(samples: dict[str, list[int]]) -> PeakValues:
|
||||
vert = _peak_ins(samples.get("Vert", []))
|
||||
long_ = _peak_ins(samples.get("Long", []))
|
||||
|
||||
# Mic in psi (approximate)
|
||||
# Mic in psi: one count = 0.25 Pa
|
||||
mic_ch = samples.get("MicL", []) or []
|
||||
mic = max((abs(int(v)) for v in mic_ch), default=0) * _MIC_FS_PSI
|
||||
mic = max((abs(int(v)) for v in mic_ch), default=0) * _MIC_PSI_PER_COUNT
|
||||
|
||||
# Peak vector sum: max over time of sqrt(T^2 + V^2 + L^2)
|
||||
pvs = 0.0
|
||||
|
||||