fix(sfm): the Series-3 header walk fails loudly, and listing uses the normal timeout
One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404. The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.
- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
a lost 1F(browse) reply on the success path and on the partial-record
path all re-raise their ProtocolError; a 1F that hands back a key
already walked raises ProtocolError("event chain did not advance ...").
Legacy calls (none of the new options) behave exactly as before --
pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.
The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.
Read-only; nothing new on the wire. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
01b9188f25
commit
59dff06f1c
4 files changed
+97
-3
No files matched your search
@@ -44,15 +44,22 @@ def test_listing_maps_each_header_into_the_shared_shape():
|
||||
assert e.filename and e.filename.startswith("T193")
|
||||
|
||||
|
||||
def test_listing_uses_the_header_walk_and_the_long_timeout():
|
||||
def test_listing_uses_the_header_walk_and_the_default_timeout():
|
||||
# A header walk is small replies only; a lost one should cost 10 s, not 120 s.
|
||||
fake = FakeMiniMateClient()
|
||||
a = adapter(fake)
|
||||
a.list_events(TCP, "BE18193")
|
||||
assert "list_event_headers" in fake.calls and "download_event_by_key" not in fake.calls
|
||||
assert a.seen == [{"timeout": 120.0}]
|
||||
assert a.seen == [{}]
|
||||
assert fake.closed == 1
|
||||
|
||||
|
||||
def test_downloading_uses_the_long_timeout():
|
||||
a = adapter(FakeMiniMateClient())
|
||||
a.download_event(TCP, "BE18193", FIRST, None)
|
||||
assert a.seen == [{"timeout": 120.0}]
|
||||
|
||||
|
||||
def test_listing_refuses_a_different_unit():
|
||||
with pytest.raises(WrongUnit):
|
||||
adapter(FakeMiniMateClient(serial="BE11529")).list_events(TCP, "BE18193")
|
||||
|
||||
Reference in new issue