diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 396dd70..2ceb32d 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2143,10 +2143,18 @@ the failure began when the pair was split across two cables and one of them was the wrong chipset. **One working and one not, set up side by side, is the signature of a mixed cable supply** — not of a unit fault. -⚠ Still worth confirming: whether that cable travelled home *with* the unit, or -was picked up separately at the bench. If it travelled with it, there is no -inference left. Either way the FTDI cable arriving 2026-09-26 settles it — same -unit, same modem, one variable. +✅ **The cable travelled home with the unit** (confirmed 2026-09-25). So the +Benfei on the bench is physically the cable from the failed office setup — not a +substitute picked up later. There is no inference left in the chain: + +| | | +|---|---| +| the cable from the failed unit | **is** a Benfei / Prolific PL2303 | +| the Micromate's USB host | has **no** Prolific driver, in either firmware line | +| a laptop on that same cable + modem | round-trips perfectly | +| the Micromate on it | never answered | + +The FTDI cable arriving 2026-09-26 is now a confirmation rather than a test. **Corollary worth knowing.** The standing workaround — *"just deploy a Series III instead"* — works partly because a **MiniMate Plus has a DB-9 port directly on the