docs(plan): the Series 3 decode checker, task by task -- and T438HGTZ is not truncated
Eight tasks: the XML report parser, SFM's side from the bytes alone, the field-by-field comparison, carve-outs (saturation first), the parallel runner, the summary and grouped detail report, run-to-run changes with a one-event view, and the first full run checked against what is known. While pinning the plan's test values on real files: T438HGTZ.B30W, called "3 samples short" by the setup-field harness, matches Blastware exactly. Its Tran, Vert and MicL end 3 samples before Long, and Blastware's own sample table does the same -- its last three rows carry only the Long cell. The harness compared Tran's length with the table's row count. The spec now says so, and the plan compares samples row by row by running channel. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
1 parent
af703808db
commit
6bdd140c29
2 files changed
+652
-2
No files matched your search
@@ -243,8 +243,10 @@ precision is a comparison rule, not a carve-out.
|
||||
- **The first run reproduces what is known**, which is how we tell the
|
||||
checker is honest:
|
||||
- sample rate, record time, pre-trigger and notes match everywhere
|
||||
- one waveform (`T438HGTZ.B30W`) is 3 samples short on Tran, Vert and
|
||||
MicL; Long is full length
|
||||
- `T438HGTZ.B30W` matches. Its Tran, Vert and MicL end 3 samples before
|
||||
Long, and Blastware's own table does the same: its last rows carry only
|
||||
the Long cell. An earlier harness that compared one channel's length with
|
||||
the table's row count called this a decoder truncation; it was not.
|
||||
- samples and histogram intervals match on the 2025–26 events, as
|
||||
`verify_against_ascii.py` showed, **except the events on the 1.250 in/s
|
||||
range**, which are 8× high (5 of them in 2025–26, 35 in all)
|
||||
|
||||