From 6c2dbf0463ce223ca14d5b11d74a2305f04eb5e0 Mon Sep 17 00:00:00 2001 From: serversdown Date: Tue, 3 Nov 2026 17:15:28 -0500 Subject: [PATCH] docs(decode_check): the units carve-out cites Instantel's manuals Both settings are documented: the unit's Microphone Units (MiniMate Plus manual s3.9.7, keypad Right Arrow + Setups: psi(L) / dB(L) / Pa(L)) and Blastware's report preference (Blastware manual s4, Preferences > Units and Channel). The report follows Blastware's, as DL2's fleet-wide switches showed. Where the unit's own setting is stored is unmeasured. Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9 --- minimateplus/decode_check_carveouts.py | 6 +++++- 1 file changed, 5 insertions(+), 1 deletion(-) diff --git a/minimateplus/decode_check_carveouts.py b/minimateplus/decode_check_carveouts.py index ff85efb..1bf3d75 100644 --- a/minimateplus/decode_check_carveouts.py +++ b/minimateplus/decode_check_carveouts.py @@ -122,7 +122,11 @@ UNITS_IS_A_DISPLAY_PREFERENCE = Carveout( "report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 " "reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or " "bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before " - "the footer). 2026-11-03."), + "the footer). Instantel documents both settings: the unit's own Microphone " + "Units (MiniMate Plus manual 716U0101 Rev 15 §3.9.7: psi(L), dB(L) or Pa(L), " + "keypad Right Arrow + Setups) and Blastware's report preference (Blastware " + "manual 714U0301 Rev 22 §4, Preferences > Units and Channel: Show Mic in dB / " + "in Linear Units). 2026-11-03."), applies=_units_is_a_display_preference, )