feat(decode): a Blastware file's identity, battery and trigger settings

Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):

- Identity block before the setup name, what the live read gets from
  SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
  date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
  minor k-193.  Event.device_info (DeviceInfo gains calibration_date /
  calibrated_by).  Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
  69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
  lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
  0x200 Manual): 6,493 / 6,493.  Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
  stop mode k-31 (0 = Fixed), each channel's float32 level at
  label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
  Weighting).  Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
  prints a level when its channel is a trigger source and the event
  was not Manual.  The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
  against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
  follows the report's dB/psi.  Carve-out
  units-is-a-display-preference: dB or psi is Blastware's PC setting
  when it wrote the report -- DL2's reports switch fleet-wide in 61
  clean runs by write time, and no byte of the file separates them.
  Two tests that pinned BatteryLevel / Calibration as blank now pin the
  match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 13:38:39 -05:00
1 parent be5bab4787
commit 6c2eda5f63
14 files changed
+8384 -15

No files matched your search

+49 -3
View File
@@ -13,6 +13,7 @@ Pure: no I/O, and no import from `sfm/`.
"""
from __future__ import annotations
import math
import re
from dataclasses import dataclass
from typing import Callable, Optional, Sequence
@@ -30,6 +31,50 @@ GEO_IPS_PER_COUNT: float = _GEO_NORMAL_FS_INS / _GEO_INT16_FS
_CHANNELS = ("Tran", "Vert", "Long", "MicL")
_EVENT_TYPE = {"Waveform": "Full Waveform", "Histogram": "Full Histogram"}
# How Blastware prints the setup fields SFM reads (measured 2026-11-03).
_MONTHS = ("January", "February", "March", "April", "May", "June", "July",
"August", "September", "October", "November", "December")
_TRIGGERED_BY = {0x0001: "Tran", 0x0002: "Vert", 0x0004: "Long", 0x0008: "MicL", 0x0200: "Manual"}
_STOP_MODES = {0: "Fixed"}
_MIC_TYPES = {2: "Linear Weighting"}
_GEO_TRIGGERS, _MIC_TRIGGER = 0x07, 0x08
# Blastware turns the mic trigger level from psi to dB with 6895 Pa per psi, not
# 6894.757: 4,272 / 4,272 DL2 levels against 4,271 (the odd one 0.01 psi,
# printed 130.8 dB(L), is 130.7498 at the exact constant).
_TRIGGER_PA_PER_PSI = 6895.0
def _setup_values(ev: Event) -> dict[str, object]:
out: dict[str, object] = {}
di = ev.device_info
if di is not None:
out["SerialNumber"] = di.serial
fw = di.firmware_version or ""
if di.dsp_version and fw.startswith("S33") and di.model:
# "V 10.72-8.17 MiniMate Plus" from "10.72", "S338.17" and the model --
# the only version in DL2, so the rule is proven for it alone.
out["Version"] = f"V {di.dsp_version}-{fw[3:]} {di.model}"
if di.calibration_date and di.calibrated_by:
c = di.calibration_date
out["Calibration"] = f"{_MONTHS[c.month - 1]} {c.day}, {c.year} by {di.calibrated_by}"
out["BatteryLevel"] = ev.battery_volts
out["Trigger"] = _TRIGGERED_BY.get(ev.triggered_by)
out["RecordStopMode"] = _STOP_MODES.get(ev.record_stop_mode)
out["Microphone"] = _MIC_TYPES.get(ev.mic_type)
# dB or psi is Blastware's preference, not the unit's (carve-out
# units-is-a-display-preference); SFM reports dB, the default.
out["Units"] = "in/s and dB(L)" if ev.mic_type is not None else "in/s"
# Blastware prints a trigger level only for a channel that is a trigger
# source, and none for a Manual trigger.
src, manual = ev.trigger_sources or 0, ev.triggered_by == 0x0200
if src & _GEO_TRIGGERS and not manual:
out["GeoTriggerLevel"] = ev.trigger_level_geo
if src & _MIC_TRIGGER and not manual and ev.trigger_level_mic_psi:
psi = ev.trigger_level_mic_psi
out["MicTriggerLevel psi(L)"] = psi
out["MicTriggerLevel dB(L)"] = 20 * math.log10(psi * _TRIGGER_PA_PER_PSI / 2e-5)
return out
@dataclass
class SfmSide:
@@ -72,6 +117,7 @@ def sfm_side(raw: bytes) -> SfmSide:
if counts["MicL"]:
values["MicLPSPL dB(L)"] = mic_count_to_db(max(abs(c) for c in counts["MicL"]))
values["MicLPSPL psi(L)"] = pv.micl if pv is not None else None
values.update(_setup_values(ev))
return SfmSide(
event=ev,
@@ -144,10 +190,10 @@ def _mic_converter(ref: XmlReport) -> Optional[Callable[[int], float]]:
def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> FieldResult:
if not printed.strip() or printed.strip() == "N/A":
return FieldResult(tag, "no_reference", printed, None)
if tag == "MicLPSPL":
if tag in ("MicLPSPL", "MicTriggerLevel"):
units = ref.event_units or ""
key = ("MicLPSPL dB(L)" if "dB(L)" in units else
"MicLPSPL psi(L)" if "psi(L)" in units else None)
key = (f"{tag} dB(L)" if "dB(L)" in units else
f"{tag} psi(L)" if "psi(L)" in units else None)
value = sfm.values.get(key) if key else None
else:
value = sfm.values.get(tag)
+22 -1
View File
@@ -106,4 +106,25 @@ INTERVAL_COUNT_IS_DURATION = Carveout(
applies=_interval_count_is_duration,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION)
_MIC_UNITS = ("in/s and dB(L)", "in/s and psi(L)")
def _units_is_a_display_preference(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
"""Both sides say the event has a mic; they differ only in dB against psi."""
return (" ".join((res.bw or "").split()) in _MIC_UNITS
and sfm.values.get("Units") in _MIC_UNITS)
UNITS_IS_A_DISPLAY_PREFERENCE = Carveout(
id="units-is-a-display-preference",
fields=("Units",),
evidence=("dB(L) or psi(L) is Blastware's display preference on the PC when it wrote the "
"report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 "
"reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or "
"bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before "
"the footer). 2026-11-03."),
applies=_units_is_a_display_preference,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION,
UNITS_IS_A_DISPLAY_PREFERENCE)
+96 -9
View File
@@ -25,7 +25,7 @@ import struct
from pathlib import Path
from typing import Optional, Union
from .models import Event, PeakValues, ProjectInfo, Timestamp
from .models import DeviceInfo, Event, PeakValues, ProjectInfo, Timestamp
from . import blastware_file as _bw # avoid circular reference at module load
from .bw_ascii_report import BwAsciiReport
from . import waveform_codec as _wc
@@ -895,17 +895,22 @@ def _ts8(b: bytes) -> Optional[datetime.datetime]:
def _embedded_event_record(
raw: bytes, end: int, start: Optional[datetime.datetime],
stop: Optional[datetime.datetime], record_time: Optional[float],
) -> tuple[Optional[datetime.datetime], str]:
"""The trigger time from the instrument's embedded event record, or (None, why).
) -> tuple[Optional[datetime.datetime], str, Optional[int]]:
"""The trigger time and trigger source from the instrument's embedded event
record, or (None, why, None).
Every `fe 80` before `end` (the footer) is a candidate. One counts only if
its lead bytes match, both its times are well formed, the footer's session
start <= trigger <= its stop, its stop is the footer's stop or a second
before it, and its length agrees with the record time. Exactly one may
pass: none, or more than one, is reported rather than guessed between.
The two bytes between the lead and `fe 80` are the trigger source, a uint16
BE bitmask: 0x01 Tran, 0x02 Vert, 0x04 Long, 0x08 MicL, 0x200 Manual --
Blastware's Trigger on 6,493 / 6,493 DL2 waveforms (2026-11-03).
"""
if start is None or stop is None:
return None, "the footer has no start and stop to check one against"
return None, "the footer has no start and stop to check one against", None
found, rejected = [], 0
i = raw.find(_EVENT_RECORD_MARKER, 6)
while 0 <= i and i + 18 <= end:
@@ -921,15 +926,15 @@ def _embedded_event_record(
<= _EVENT_RECORD_SLACK_S[1])
)
if valid:
found.append(trig)
found.append((trig, int.from_bytes(raw[i - 2:i], "big")))
else:
rejected += 1
i = raw.find(_EVENT_RECORD_MARKER, i + 1)
if len(found) == 1:
return found[0], ""
return found[0][0], "", found[0][1]
if found:
return None, f"{len(found)} candidates validate"
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
return None, f"{len(found)} candidates validate", None
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate"), None
def _parse_record_time_seconds(raw: bytes) -> Optional[float]:
@@ -1047,6 +1052,83 @@ def _setup_geo_range(raw: bytes) -> tuple[Optional[int], Optional[str]]:
return None, f"geophone range not read: channel range bytes {found}"
# The identity block before the setup: what the live read gets from SUB FE
# (DeviceInfo). Offsets back from k, the setup name; matched against every DL2
# report 2026-11-03 -- serial, version and calibration 69,983 / 69,983, the
# battery 69,729 plus 254 that Blastware rounds half up (6.25 -> "6.3 Volts").
_SERIAL_BEFORE_NAME = 202 # ASCII, NUL-terminated
_BATTERY_BEFORE_NAME = 190 # uint16 BE, hundredths of a volt
_FIRMWARE_MINOR_BEFORE_NAME = 193 # 0x11 = 17 for S338.17, as SUB EA
_FIRMWARE_BEFORE_NAME = 147 # "S338.17"
_DSP_BEFORE_NAME = 138 # "10.72"
_CALIBRATION_BEFORE_NAME = 132 # dd mm yyyy (BE)
_CALIBRATED_BY_BEFORE_NAME = 128 # "Instantel"
_MANUFACTURER_BEFORE_NAME = 94 # "Instantel"
_MODEL_BEFORE_NAME = 72 # "MiniMate Plus" / "BlastMate III"
def _cstr(raw: bytes, i: int, limit: int = 40) -> Optional[str]:
if i < 0:
return None
j = raw.find(b"\x00", i, i + limit)
s = raw[i:j if j >= 0 else i + limit].decode("ascii", errors="replace").strip()
return s or None
def _setup_identity(raw: bytes, k: int) -> tuple[Optional[DeviceInfo], Optional[float]]:
"""(the unit's identity, the battery in volts) from the block before the
setup name at k."""
if k < _SERIAL_BEFORE_NAME:
return None, None
serial = _cstr(raw, k - _SERIAL_BEFORE_NAME, 16)
if not serial:
return None, None
c = k - _CALIBRATION_BEFORE_NAME
try:
cal = datetime.date(int.from_bytes(raw[c + 2:c + 4], "big"), raw[c + 1], raw[c])
except ValueError:
cal = None
info = DeviceInfo(
serial=serial,
firmware_minor=raw[k - _FIRMWARE_MINOR_BEFORE_NAME],
firmware_version=_cstr(raw, k - _FIRMWARE_BEFORE_NAME, 9),
dsp_version=_cstr(raw, k - _DSP_BEFORE_NAME, 6),
manufacturer=_cstr(raw, k - _MANUFACTURER_BEFORE_NAME),
model=_cstr(raw, k - _MODEL_BEFORE_NAME),
calibration_date=cal,
calibrated_by=_cstr(raw, k - _CALIBRATED_BY_BEFORE_NAME, 32),
)
b = k - _BATTERY_BEFORE_NAME
return info, int.from_bytes(raw[b:b + 2], "big") / 100
# Trigger settings, in Series IV's 0x1A layout again: the trigger-source bitmask
# at k - 19 ([29]: 0x07 geophones, 0x08 mic), the stop mode at k - 31 ([17],
# 0 = Fixed), and each channel block's trigger level, a float32 at label + 30 --
# in/s for a geophone, psi for the mic. The mic block's type code at label + 4
# is Series IV's (2 = linear). Against every DL2 waveform (2026-11-03): the geo
# level 6,447 / 6,447, the mic level 4,403 / 4,403, and Blastware prints a level
# exactly when its channel is a trigger source and the event was not Manual.
_TRIGGER_SOURCES_BEFORE_NAME = 19
_STOP_MODE_BEFORE_NAME = 31
_TRIGGER_LEVEL_AFTER_LABEL = 30
_MIC_TYPE_AFTER_LABEL = 4
def _setup_trigger(raw: bytes, k: int) -> dict:
out = {"trigger_sources": raw[k - _TRIGGER_SOURCES_BEFORE_NAME],
"record_stop_mode": raw[k - _STOP_MODE_BEFORE_NAME]}
t = raw.find(b"\x00\x00\x01Tran", k, k + _CHANNEL_BLOCK_SPAN)
if t >= 0:
p = t + 3 + _TRIGGER_LEVEL_AFTER_LABEL
out["trigger_level_geo"] = struct.unpack_from(">f", raw, p)[0]
m = raw.find(b"MicL", k, k + _CHANNEL_BLOCK_SPAN)
if m >= 0:
out["trigger_level_mic_psi"] = struct.unpack_from(">f", raw, m + _TRIGGER_LEVEL_AFTER_LABEL)[0]
out["mic_type"] = int.from_bytes(raw[m + _MIC_TYPE_AFTER_LABEL:m + _MIC_TYPE_AFTER_LABEL + 4], "big")
return out
def read_blastware_file(path: Union[str, Path], *, name: Optional[str] = None) -> Event:
"""Parse a Blastware event file into an Event: `decode_blastware_bytes` on its
bytes, `name` defaulting to the file's own (see there -- never a time source)."""
@@ -1236,6 +1318,11 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
ev.geo_range, range_problem = _setup_geo_range(raw)
if range_problem:
ev.decode_problems.append(range_problem + "; peaks assume the Normal range")
k = _setup_name_at(raw)
if k is not None:
ev.device_info, ev.battery_volts = _setup_identity(raw, k)
for attr, value in _setup_trigger(raw, k).items():
setattr(ev, attr, value)
if is_waveform_body:
ev.rectime_seconds = _setup_record_time(raw)
ev.total_samples = len(samples["Tran"]) or None
@@ -1276,7 +1363,7 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
_rt = _parse_record_time_seconds(raw)
_start = (datetime.datetime(ts1.year, ts1.month, ts1.day, ts1.hour, ts1.minute, ts1.second)
if ts1 is not None else None)
_trig, _why = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
_trig, _why, ev.triggered_by = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
if _trig is not None:
ev.timestamp_source = "event_record"
else:
+13
View File
@@ -300,6 +300,10 @@ class DeviceInfo:
# ── From SUB 08 (EVENT_INDEX_RESPONSE) ────────────────────────────────────
event_count: Optional[int] = None # stored event count from F7 response 🔶
# ── From a Blastware event file's identity block (2026-11-03) ─────────────
calibration_date: Optional[datetime.date] = None # e.g. 2019-02-20 ✅
calibrated_by: Optional[str] = None # e.g. "Instantel" ✅
def __str__(self) -> str:
fw = self.firmware_version or f"?.{self.firmware_minor}"
mdl = self.model or "MiniMate Plus"
@@ -548,6 +552,15 @@ class Event:
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
geo_range: Optional[int] = None
# From a Blastware event file (2026-11-03); None when not read.
device_info: Optional["DeviceInfo"] = None # the unit, as SUB FE reports it
battery_volts: Optional[float] = None # at the event
triggered_by: Optional[int] = None # 0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL 0x200 Manual
trigger_sources: Optional[int] = None # setup bitmask: 0x07 geophones, 0x08 mic
trigger_level_geo: Optional[float] = None # in/s, as ComplianceConfig.trigger_level_geo
trigger_level_mic_psi: Optional[float] = None
record_stop_mode: Optional[int] = None # 0 = Fixed
mic_type: Optional[int] = None # 2 = Linear Weighting (as Series IV)
# Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring