feat(decode): a Blastware file's identity, battery and trigger settings

Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):

- Identity block before the setup name, what the live read gets from
  SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
  date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
  minor k-193.  Event.device_info (DeviceInfo gains calibration_date /
  calibrated_by).  Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
  69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
  lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
  0x200 Manual): 6,493 / 6,493.  Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
  stop mode k-31 (0 = Fixed), each channel's float32 level at
  label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
  Weighting).  Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
  prints a level when its channel is a trigger source and the event
  was not Manual.  The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
  against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
  follows the report's dB/psi.  Carve-out
  units-is-a-display-preference: dB or psi is Blastware's PC setting
  when it wrote the report -- DL2's reports switch fleet-wide in 61
  clean runs by write time, and no byte of the file separates them.
  Two tests that pinned BatteryLevel / Calibration as blank now pin the
  match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 13:38:39 -05:00
1 parent be5bab4787
commit 6c2eda5f63
14 files changed
+8384 -15

No files matched your search

+13
View File
@@ -300,6 +300,10 @@ class DeviceInfo:
# ── From SUB 08 (EVENT_INDEX_RESPONSE) ────────────────────────────────────
event_count: Optional[int] = None # stored event count from F7 response 🔶
# ── From a Blastware event file's identity block (2026-11-03) ─────────────
calibration_date: Optional[datetime.date] = None # e.g. 2019-02-20 ✅
calibrated_by: Optional[str] = None # e.g. "Instantel" ✅
def __str__(self) -> str:
fw = self.firmware_version or f"?.{self.firmware_minor}"
mdl = self.model or "MiniMate Plus"
@@ -548,6 +552,15 @@ class Event:
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
geo_range: Optional[int] = None
# From a Blastware event file (2026-11-03); None when not read.
device_info: Optional["DeviceInfo"] = None # the unit, as SUB FE reports it
battery_volts: Optional[float] = None # at the event
triggered_by: Optional[int] = None # 0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL 0x200 Manual
trigger_sources: Optional[int] = None # setup bitmask: 0x07 geophones, 0x08 mic
trigger_level_geo: Optional[float] = None # in/s, as ComplianceConfig.trigger_level_geo
trigger_level_mic_psi: Optional[float] = None
record_stop_mode: Optional[int] = None # 0 = Fixed
mic_type: Optional[int] = None # 2 = Linear Weighting (as Series IV)
# Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring