client/models/server: wire event_count from SUB 08 event index into connect()
- DeviceInfo.event_count: Optional[int] = None (new field in models.py) - connect() now calls proto.read_event_index() after compliance config and stores the decoded count in device_info.event_count - _serialise_device_info() exposes event_count in /device/info and /device/events JSON responses event_count is decoded from uint32 BE at offset +3 of the 88-byte F7 payload (🔶 inferred — needs live device confirmation against a multi-event device). Any ProtocolError from the index read is caught and logged; event_count stays None rather than failing the whole connect(). Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -121,9 +121,10 @@ class MiniMateClient:
|
||||
2. SUB 15 — serial number
|
||||
3. SUB 01 — full config block (firmware, model strings)
|
||||
4. SUB 1A — compliance config (record time, trigger/alarm levels, project strings)
|
||||
5. SUB 08 — event index (stored event count)
|
||||
|
||||
Returns:
|
||||
Populated DeviceInfo with compliance_config cached.
|
||||
Populated DeviceInfo with compliance_config and event_count cached.
|
||||
|
||||
Raises:
|
||||
ProtocolError: on any communication failure.
|
||||
@@ -151,6 +152,14 @@ class MiniMateClient:
|
||||
except ProtocolError as exc:
|
||||
log.warning("connect: compliance config read failed: %s — continuing", exc)
|
||||
|
||||
log.info("connect: reading event index (SUB 08)")
|
||||
try:
|
||||
idx_raw = proto.read_event_index()
|
||||
device_info.event_count = _decode_event_count(idx_raw)
|
||||
log.info("connect: device has %d stored event(s)", device_info.event_count)
|
||||
except ProtocolError as exc:
|
||||
log.warning("connect: event index read failed: %s — continuing", exc)
|
||||
|
||||
log.info("connect: %s", device_info)
|
||||
return device_info
|
||||
|
||||
|
||||
@@ -183,6 +183,9 @@ class DeviceInfo:
|
||||
# ── From SUB 1A (COMPLIANCE_CONFIG_RESPONSE) ──────────────────────────────
|
||||
compliance_config: Optional["ComplianceConfig"] = None # E5 response, read in connect()
|
||||
|
||||
# ── From SUB 08 (EVENT_INDEX_RESPONSE) ────────────────────────────────────
|
||||
event_count: Optional[int] = None # stored event count from F7 response 🔶
|
||||
|
||||
def __str__(self) -> str:
|
||||
fw = self.firmware_version or f"?.{self.firmware_minor}"
|
||||
mdl = self.model or "MiniMate Plus"
|
||||
|
||||
Reference in New Issue