From 71609e71ab9e303211bf2352a486f9ca4b7e2ae7 Mon Sep 17 00:00:00 2001 From: serversdown Date: Tue, 3 Nov 2026 18:51:53 -0500 Subject: [PATCH] docs(plan): phase 5 -- changing a unit's settings by serial Seven tasks: the Series 3 read assembly, one settings codec for both series, the Micromate schedule read, each series' audited change, the route (and the legacy write retired), and the page. Spans measured from 75,958 Blastware reports. Bench after the final review, Brian's go per send. Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44 --- .../plans/2026-11-03-sfm-phase5-settings.md | 519 ++++++++++++++++++ 1 file changed, 519 insertions(+) create mode 100644 docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md diff --git a/docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md b/docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md new file mode 100644 index 0000000..c1a0066 --- /dev/null +++ b/docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md @@ -0,0 +1,519 @@ +# Phase 5: Changing a Unit's Settings by Serial — Implementation Plan + +> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking. + +**Goal:** An operator edits a unit's live settings in SFM, by serial, on either series: preview old → new, send once (audited), and see what the unit now holds. + +**Architecture:** +- **One pure settings codec for both series** (`micromate/setup_fields.py`), on the measured shared 2,090-byte layout. +- **Each series' adapter supplies reads, the plan and the send** to the existing `run_change` core, unchanged. + - Its "state" is a read-back verdict: `as asked` / `unchanged` / `differs`. + - Series 3 sends through `push_config_raw`; Series 4 through `plan_setup_push`. + - Series 4 also reads the unit's schedule, read-only, to refuse a change that a scheduled start would undo. +- **One audited route**, `POST /device/settings/change`. The legacy by-host write is retired. + +**Tech Stack:** Python 3 (FastAPI, pytest), vanilla JS tested in Node (`tests/test_webapp_device_routing.py`). + +**Spec:** `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md` (approved by Brian 2026-11-03). Parent spec: `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`. + +## Global Constraints + +- **Worktree and branch:** work in `~/seismo-relay-parity` on `feat/series4-sfm-parity`. Check `git branch --show-current` before every commit; never commit to `main`; push every commit. +- **Python:** `/home/serversdown/seismo-relay/.venv/bin/python -m pytest …` from the worktree root. +- **The suite has 16 known failures.** + - Run the full suite once before Task 1 and save the failure list in the plan workspace as `baseline-failures.txt`. + - Before every commit, run the suite, read the failure list, and confirm it equals the baseline. + - Commit in a separate call, never chained to the test run. +- **No live device traffic** in any task. The bench is after the final review, with Brian's explicit go per send. + - Never port 8200. + - Never write modem baud or modem type. + - Never send `0xA2`. +- **`CHANGELOG.md` is not touched** on this branch; it is written on `dev` at the merge. +- **No inline JavaScript.** New page logic goes in `sfm/static/device_routing.js` (DOM-free, Node-tested); glue goes in `sfm/static/sfm_webapp.js`. +- **`docs/instantel_protocol_reference.md` is CRLF.** Edit it only with the Edit tool. Keep its rows in date order. +- **Off-limits (the checker session's files):** `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`. +- **`TOOL_VERSION` is unchanged:** nothing here changes event decoding. Operational consequence: none; no migration, no backfill. +- **Grade every protocol claim** in comments and docs as measured or inferred. +- **Mutation checks:** after a mutate/restore, delete the module's `__pycache__/*.pyc` before the confirming run. + +## Review Focus + +1. **A Micromate with no schedule file, or a schedule read that fails.** + - A body with no records means no conflict, and the change proceeds. + - A read that raises refuses the change in plain words. + - Owner: Task 4; tests `test_no_schedule_records_is_no_conflict` and `test_an_unreadable_schedule_refuses`. +2. **A float that is stored as f32.** 0.3 reads back as 0.30000001192. + - The verdict compares bytes with the image written, never floats, so it reads `as asked`. + - Owner: Task 2; test `test_f32_values_read_back_as_asked`. +3. **A stale or foreign revision** after a keypad edit, or a preview of another unit. + - The send is refused with 409, nothing is sent, and no audit row is written. + - Owner: Tasks 4 and 5; tests `test_s4_stale_revision_sends_nothing` and `test_s3_stale_revision_sends_nothing`. +4. **Range and trigger changed in one request.** The trigger is checked against the **new** range. + - Owner: Task 2; test `test_trigger_checked_against_the_new_range`. +5. **Notes at the edges.** + - `""` clears a note. + - 41 bytes is accepted; 42 is refused; non-ASCII is refused. + - Labels are never written. + - Owner: Task 2; tests `test_note_edges` and `test_note_labels_are_never_written`. + +--- + +## File Structure + +| file | responsibility | +|---|---| +| `minimateplus/protocol.py` | **Series 3 assembly:** `assemble_compliance_content`, `is_compliance_content`, `MiniMateProtocol.read_compliance_content`. **Writes:** `push_config_raw`'s pre-check raises `ImageRefused`. | +| `minimateplus/client.py` | **Added:** `read_compliance_content()` and `read_settings_blocks()`. **Deleted:** `apply_config`, `set_project_info`, `_encode_compliance_config`. | +| `micromate/setup_block.py` | **Added:** `with_crc(content)`. | +| `micromate/setup_fields.py` (new) | **The shared, pure settings codec:** field registry, `editable_fields`, `check_changes`, `encode_setup`, `field_values`, `settings_state`, `revision`. | +| `micromate/schedule.py` (new) | **Pure:** `parse_schedule`, `ScheduleEntry`, `schedule_conflicts`. | +| `micromate/protocol.py` | **Added:** `read_file(path)`, using `0x94` then `0x48` pages. | +| `micromate/client.py` | **Added:** `read_schedule()`, `get_active_setup_raw()`, `get_prefs_content()`, `get_trigger_content()`, `get_setup_content()`. | +| `micromate/opcodes.py` | `ENABLEABLE_WRITES` gains the setup-push SUBs. | +| `sfm/device_access/errors.py` | **Added:** `SettingsChanged` and `ChangeRefused`, both 409. | +| `sfm/device_access/change.py` | **Added:** `settings_change()`. | +| `sfm/device_access/s4.py` | `s4_settings` moves onto the codec. **Added:** `s4_change_settings`. | +| `sfm/device_access/s3.py` | `Series3Adapter.settings` moves onto the codec. **Added:** `Series3Adapter.change_settings`. | +| `sfm/device_access/access.py` | **Added:** `DeviceAccess.change_settings`. | +| `sfm/server.py` | **Added:** `POST /device/settings/change`. `/device/config` and `/device/config/project` return 410. | +| `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html` | The edit form. | +| `tests/device_access_fakes.py` | The fakes gain settings blocks, a schedule, and writes. | + +--- + +### Task 1: Series 3 — assemble a settings read into the logical block + +**Measured basis (spec, 2026-11-03):** unescape each `1A` data frame and take `data[11:]`. Every frame but the last starts with one non-content `00` byte; drop it. The result is 2,090 bytes with `N = 2090` at `[0:2]`. + +**Files:** +- Modify: `minimateplus/protocol.py`, near `read_compliance_config` (≈ line 913) +- Modify: `minimateplus/client.py` +- Modify: `docs/instantel_protocol_reference.md` (one dated row, 2026-11-03) +- Test: `tests/test_s3_settings_read.py` (new) + +**Interfaces:** +- Produces: + - `assemble_compliance_content(frames: list[bytes]) -> bytes`. `frames` is each data reply's `frame.data`, escapes kept, in order. + - `is_compliance_content(block: bytes) -> bool`: `len == 2090` and `int.from_bytes(block[0:2], "big") == 2090`. + - `COMPLIANCE_CONTENT_LEN = 2090`. + - `MiniMateProtocol.read_compliance_content() -> bytes`: + - sends the same probe and B/C/D requests as `read_compliance_config`; + - a missing data frame raises `ProtocolError` (no `continue`); + - returns the assembled bytes **without** judging them, so a monitoring unit's device-info answer comes back for the caller to recognise. + - `MiniMateClient.read_compliance_content() -> bytes`. + - `MiniMateClient.read_settings_blocks() -> dict` with keys `event_index`, `compliance`, `trigger` and `waveform`. Each value is the bytes its existing read returns: + - `event_index`: `proto.read_event_index()` + - `compliance`: `read_compliance_content()` + - `trigger`: `proto.read_trigger_config()` + - `waveform`: `proto.read_waveform_data_raw()` + +- [ ] **Step 1: Write the failing tests** in `tests/test_s3_settings_read.py`. Use `tests/fixtures/minimate-bench-10-26-26-histogram` (`unit_replies.bin` parsed with `S3FrameParser`). Group the `0xE5` frames into reads: a frame with `len(data) == 11` starts each read. Take the write images from `tests/test_minimate_write_frames.py` (`WRITES[0:13]`, `WRITES[13:26]`; the `0x71` payloads `[16:]` joined). + +```python +def test_reads_assemble_to_2090_bytes(): # all 12 reads, both frame patterns (5 and 3 frames) + assert all(len(assemble_compliance_content(r)) == 2090 for r in READS) + +def test_a_read_after_a_blastware_write_equals_the_write(): + assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090] + assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090] + +def test_a_monitoring_units_answer_is_not_settings(): # READS[3:8] start 0e 'BE9441' + assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5 + assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:]) + +def test_read_compliance_content_refuses_a_missing_frame(): + ... # a fake transport that answers the probe and frame B, then times out: ProtocolError, nothing assembled +``` + +- [ ] **Step 2: Run them.** `…pytest tests/test_s3_settings_read.py -q`. Expected: FAIL (ImportError: `assemble_compliance_content`). +- [ ] **Step 3: Implement** the Produces block in `protocol.py` and `client.py`. Use `unescape_reply` from `minimateplus.framing`. The docstring cites the measurement and its fixture. +- [ ] **Step 4: Run them.** Expected: PASS (4 passed). +- [ ] **Step 5: Add a reference row** to `docs/instantel_protocol_reference.md` (Edit tool; CRLF), dated 2026-11-03, measured. Cover: + - the assembly rule; + - the round trip (2 of 2); + - `[26:28]`: Blastware writes `00 00` (11 of 11), and the unit sets `01 7f` after monitoring; + - the trailing two bytes: a per-unit Blastware constant (`7c ea` BE11529 ×9, `0c e9` BE9441 ×2), not the CRC, and never in a reply; + - `0x09 [200:202]`: echoed 9 of 9 in April; changed on 10-26 (`17 17` → `78 76`). +- [ ] **Step 6: Run the full suite** and compare the failure list with the baseline. **Then commit** (separate call): `feat(s3): assemble a settings read into the 2,090-byte block`. + +--- + +### Task 2: The shared settings codec + +**Files:** +- Create: `micromate/setup_fields.py` +- Modify: `micromate/setup_block.py`: add `with_crc(content: bytes) -> bytes`, which returns the content with `CRC-16/AUG-CCITT` over `[0:N-2]` written BE at `[N:N+2]`. +- Test: `tests/test_setup_fields.py` (new) + +**Interfaces:** +- Consumes: Task 1's `assemble_compliance_content`, used in tests only. The codec itself imports nothing from `minimateplus` and nothing from `sfm`. +- Produces (all pure). Each `content` is the 2,090-byte (Series 3) or 2,092-byte (Series 4) block. + - `editable_fields(content: bytes, series: int) -> list[dict]`. Each dict has `field`, `label`, `kind` (`"number"`, `"choice"`, `"text"` or `"bool"`) and `value`, plus as relevant `unit`, `min`, `max`, `choices` (a list of `{value, label}`) and `maxlength`. + - `field_values(content: bytes, series: int) -> dict[str, Any]`: the same fields, values only. + - `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, spans) and content-dependent (unit strings, the trigger against the range). + - `encode_setup(content: bytes, series: int, changes: dict) -> bytes`: + - same length as `content`; + - only the changed fields' bytes move; + - bit fields are patched bit by bit; + - Series 3 also sets `[26:28] = 00 00` (`S3_BLASTWARE_FIXED`); + - Series 4 returns `with_crc(...)`. + - `settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str`. It compares `[0:2090]`: + - `"as asked"` if `now` equals `written` (Series 4 also needs `crc_ok(now)`); + - else `"unchanged"` if `now` equals `before`; + - else `"differs"`. + - `revision(blocks: list[bytes]) -> str` = `hashlib.sha256(b"".join(blocks)).hexdigest()[:16]`. + - `S3_ALARM_WRITE_MEASURED = False`. While False, `geo_alarm_ips` is shown (read-only, `kind` plus `"readonly": True`) and refused in `check_changes`. + +**The field registry** (content offsets; channel `k` = `1708 + 48·k`, `k` = 0, 1, 2 for the geophones): + +| field | series | bytes | values (exact) | +|---|---|---|---| +| `record_mode` | 3 | `[5]` | `single_shot`=0, `continuous`=1, `histogram`=3, `histogram_continuous`=4 | +| `record_mode` | 4 | `[5]` | `waveform`=1, `manual`=2, `histogram`=3, `combo`=4 | +| `sample_rate` | 3, 4 | `[6:8]` u16 BE | {1024, 2048, 4096} | +| `histogram_interval_s` | 3, 4 | `[8:10]` u16 BE | {2, 5, 15, 60, 300, 900} | +| `record_time_s` | 3, 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 20.0 | +| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 0.6, and ≤ the (new) range's full scale (10.0 / 1.25) | +| `geo_range` | 3 | ch k `+29` u8, all three | `normal`=0, `sensitive`=1 | +| `geo_alarm_ips` | 3 (gated) | ch k `+38` f32 BE, all three | 0.005 ≤ v ≤ full scale | +| `job_number` | 3, 4 | `[40:42]` u16 BE | 0 ≤ v ≤ 65535 | +| `job_number_shown` | 3, 4 | `[39]` bit `0x02` | bool | +| `note_1` … `note_4` | 3, 4 | value `[144+64n : 186+64n]`; label `[122+64n : 144+64n]` read only | printable ASCII 0x20–0x7E, ≤ 41 bytes, zero-filled to 42 | + +Where the spans come from, recorded in the module as comments: +- **Trigger and record time:** 75,958 Blastware reports, 2016–2026, scanned 2026-11-03. 7,586 print a trigger: 0.005–0.500 in/s, 20 values, all in/s. 7,631 print a record time: 1.0–10.0 s. +- **The tops of the spans:** BE11529's 2026-04-20 writes and the UM20147 fixtures (trigger 0.6, record time 11), and BE9441's 10-26 setup (record time 20). +- **Job number:** bounded by its encoding (UM20147 keypad 0 → 1 → 1234). The read-back verifies it. + +**A level write is refused** unless all three geophone channels' unit string, `ch +34:+38` with NULs and `.` stripped, equals `in`. Measured: `in.` and `in` both occur on UM20147. A unit set to Metric is unmeasured. + +- [ ] **Step 1: Write the failing tests** in `tests/test_setup_fields.py`: + +```python +def test_s3_reproduces_every_blastware_write(): + # BE11529's 9 April images (bridges/captures/4-20-26/**/raw_bw_*.bin), in time order (the HHMMSS in + # the name): before = the previous image; the first (151921) uses the assembled 1A read in its own + # raw_s3 capture if that read is whole, else it is skipped (say so in the test). BE9441's 2 images: + # before = the assembled READS[0], then image 1. changes = field_values(after) for every field whose + # value differs. Assert encode_setup(before, 3, changes)[:2090] == after[:2090]. + # The 16:26 write also moves [25] (mic on): include `_sensors_mic` as a test-only patch helper, + # not a registry field. + +def test_s4_fixture_pairs_reproduce(): + # for every ordered pair (a, b) of tests/fixtures/micromate-setup/*.bin whose differing bytes outside + # [2090:2092] all lie inside registry fields: encode_setup(a, 4, {f: field_values(b)[f] for differing f}) == b + +def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 0.6} passes; a fake full scale below 0.6 refuses +def test_spans_refuse_outside_values(): ... # 0.004 and 0.61 in/s; 0.9 and 20.1 s; sample rate 8192; interval 30 +def test_field_not_offered_for_the_series(): ... # geo_range on series 4 -> SettingsValueError naming the series +def test_alarm_is_read_only_until_measured(): ... # Series 3 geo_alarm_ips -> SettingsValueError while S3_ALARM_WRITE_MEASURED is False +def test_metric_unit_string_refuses_level_writes(): ... # ch +34 = b"mm\x00\x00" -> SettingsValueError; b"in.\x00" and b"in\x00\x00" pass +def test_note_edges(): ... # "" clears; 41 bytes ok; 42 refused; "café" refused +def test_note_labels_are_never_written(): ... # changing note_2 moves only [208:250] +def test_bit_fields_keep_unknown_bits(): ... # [39] = 0x81: job_number_shown True -> 0x83, False -> 0x81 +def test_s3_fixed_bytes(): ... # any S3 encode sets [26:28] = 00 00 +def test_s4_encode_recomputes_the_crc(): ... # crc_ok(encode_setup(fixture, 4, {"job_number": 7})) +def test_f32_values_read_back_as_asked(): ... # written = encode(0.3); settings_state(before, written, written) == "as asked" +def test_settings_state(): ... # "as asked" / "unchanged" / "differs"; S4 with a bad CRC -> "differs" +def test_revision_is_stable_and_content_sensitive(): ... +``` + +- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.setup_fields`). +- [ ] **Step 3: Implement** `micromate/setup_fields.py` and `with_crc`. Decode via the registry (not via `decode_setup`, whose notes are keyed by label). Note labels come from the unit and are display only. +- [ ] **Step 4: Run them.** Expected: PASS. Then mutation-check `S3_BLASTWARE_FIXED` (remove it: the Blastware-write test fails), delete the `.pyc`, and restore. +- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(codec): one settings codec for both series, on the shared layout`. + +--- + +### Task 3: Micromate — read the schedule file + +**Measured basis:** reference *The scheduler, and a generic file transfer* and *The schedule record format*. +- `0x94 ` opens a file for read; `offset` = the path's length, and the payload is the path, unpadded. +- `0x48` reads the next page, repeated until an all-zero 11-byte response. +- The file is 260-byte records. `[4]` is the half-hour slot. `[6]` is the action bitmask: 2 start-with-setup, 4 stop, 8 self-check, 16 ACH. `[7]` is the name length; `[8:260]` is the name. + +**Files:** +- Create: `micromate/schedule.py` +- Modify: `micromate/protocol.py` (`read_file`), `micromate/client.py` +- Modify: `docs/micromate_protocol_reference.md`: one line under the scheduler section saying SFM reads it (read-only) from 2026-11-03. +- Test: `tests/test_micromate_schedule.py` (new) + +**Interfaces:** +- Produces: + - `SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"`. + - `MicromateProtocol.read_file(path: str) -> bytes`: the concatenated content of each `0x48` page after the page-0 descriptor, stopping at the all-zero response; at most 64 pages, else `ProtocolError`. + - `MicromateClient.read_schedule() -> bytes`. + - `MicromateClient.get_active_setup_raw() -> str`: the `0x41` name up to its NUL, **not** stripped. + - `MicromateClient.get_prefs_content() -> bytes` (`0x08`), `get_trigger_content() -> bytes` (`0x2E`) and `get_setup_content() -> bytes` (`0x1A`), each `_content(...)` of its read. + - `@dataclass(frozen=True) class ScheduleEntry`: `index: int`, `time: str` (`"HH:MM"`), `day: int`, `action_bits: int`, `actions: tuple[str, ...]`, `setup: str`. + - `parse_schedule(body: bytes) -> list[ScheduleEntry]`: 260-byte records; a record with `[4:8]` all zero and no name ends the list. `actions` names the bits 2/4/8/16 as `start_with_setup`, `stop`, `self_check` and `call_home`; any other bit becomes `unknown(0xNN)`. + - `schedule_conflicts(entries, active_setup: str) -> list[ScheduleEntry]`: start entries whose setup, compared case-insensitively after `strip()`, is not the active setup. + +- [ ] **Step 1: Write the failing tests.** Parse the bodies from `bridges/captures/9-24-26 - micromate2/raw_s3_20260924_191835_read_scheduler.bin` (frames 0–4), and from the two `raw_*_20260925_*` captures, with `MicromateFrameParser`. + +```python +def test_the_read_capture_parses(): # 2 records: start-with-setup 07:30 (40-char name), call_home 19:30 (no name) +def test_the_five_entry_schedule_parses(): # 07:30 start TEST1.mmb, 08:00 stop, 08:30 self_check, 09:00 start test2.mmb, 19:30 call_home +def test_conflicts_are_case_insensitive(): # active "test1.MMB" -> only the test2.mmb start conflicts +def test_no_schedule_records_is_no_conflict(): assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == [] +def test_read_file_sends_the_path_unpadded_and_stops_at_zeros(): ... # a fake protocol: 0x94 offset 0x001D, then 0x48 until all-zero +def test_get_active_setup_raw_keeps_spaces(): ... # " LOC 4 .mmb " survives +``` + +- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.schedule`). +- [ ] **Step 3: Implement** the Produces block. `read_file` builds `0x94` with `build_request(0x94, len(path), bytes(10), path.encode("ascii"))`. Both SUBs are already in `READ_SUBS`. +- [ ] **Step 4: Run them.** Expected: PASS. +- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(micromate): read the schedule file (read-only)`. + +--- + +### Task 4: Change-path pieces and the Series 4 settings change + +**Files:** +- Modify: `sfm/device_access/errors.py`, `sfm/device_access/change.py`, `micromate/opcodes.py`, `sfm/device_access/s4.py`, `tests/device_access_fakes.py` +- Modify: `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`. Their over-ceiling example `0x71` becomes enableable here; use `0xA8` (delete one event) instead. +- Test: `tests/test_device_access_s4_settings.py` (new) + +**Interfaces:** +- Consumes: + - Task 2: `editable_fields`, `field_values`, `check_changes`, `encode_setup`, `settings_state`, `revision`. + - Task 3: `read_schedule`, `parse_schedule`, `schedule_conflicts`, `get_active_setup_raw`, and the content getters. + - `micromate.writes.plan_setup_push(prefs, trigger, setup, name)`. +- Produces: + - `class SettingsChanged(DeviceError)`, `http_status = 409`. + - `class ChangeRefused(DeviceError)`, `http_status = 409`. + - `settings_change() -> ChangeKind("change settings", "as asked", "applied")`. + - `ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F, 0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})`. + - `s4_settings(client, serial) -> UnitSettings`. It keeps every current field, plus `detail["editable"] = editable_fields(setup, 4)`. The revision comes only from a preview (dry run), never from this read. + - `s4_change_settings(client, serial, *, changes: dict, revision: Optional[str], dry_run: bool, audit, address, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`. + +**`s4_change_settings` behaviour**, through `run_change` (`even_if_already=False`): + +- **`read_state`, first call:** + - Read the run state. + - `calling_home` and `unknown*` are returned as they are. + - `monitoring` raises `UnitStateUnknown(f"{serial} is monitoring -- stop it first (a stop makes it call in if call-home is on) -- nothing sent")`. + - Read the name (raw), prefs, trigger and setup. + - `check_changes` (a `SettingsValueError` becomes `BadRequest`). + - When live, `revision([name.encode("ascii"), prefs, trigger, setup])` must equal the request's. Otherwise raise `SettingsChanged("the unit's settings changed since the preview -- preview again; nothing sent")`. + - `image = encode_setup(setup, 4, changes)`. + - Read the schedule; a read error is kept as a blocking reason. + - Return `settings_state(setup, image, setup, series=4)`. +- **Later calls:** read the setup and return `settings_state(before, image, now, series=4)`. +- **`describe_plan`:** + - `plan_setup_push(prefs, trigger, image, name).describe()`, plus `fields` = `{f: {label, old, new}}` for the changed fields, `revision`, `warnings` and `blocked`. + - `warnings` always includes: "this reads the unit's keypad edit buffer: if someone is in its menu, their unsaved edits are sent too". + - `blocked`: + - the name is `factory.MMB` (case-insensitive): "this unit is running its factory setup; load any other setup on its keypad, then try again"; + - each schedule conflict: "this unit's schedule loads at , which would replace this change"; + - a schedule read error: "could not read this unit's schedule () -- SFM will not change a unit whose schedule it cannot check"; + - `plan_setup_push` raising `ValueError` (a block size or header THOR's offsets were never seen at, or a failed checksum): "this unit's -- SFM has not seen a block like it". + - When `blocked` is non-empty, `steps` is `[]`, and a live call raises `ChangeRefused("; ".join(blocked) + " -- nothing sent")`. + - When the schedule names the active setup, `warnings` adds: "the unit's schedule loads this setup at ; the change survives it". +- **`send`:** `client.protocol.execute(plan)`, as `s4_change_call_home` does. +- **`snapshot`:** + - `fields`: `{f: {label, old, new, now}}`; + - `before` / `after` hex of the setup; + - `changed_offsets`; + - `prefs` and `trigger`: before hex only. +- **`is_refusal`**, **`is_ring`** and **`pre_send`**: as in `s4_change_call_home`. + +**Validation order:** a live call without `revision` is refused before any I/O, in Task 6's `DeviceAccess` (not here). + +- [ ] **Step 1: Write the failing tests.** Extend `FakeMicromateClient` with: + - `setup` (default: `tests/fixtures/micromate-setup/um20147_baseline.bin`'s last 2,092 bytes); + - `prefs`, `trigger` and `active_name` (default `"test2.mmb"`); + - `schedule_body` (default `bytes(524)`) and `schedule_error`; + - `execute` applies a setup-push plan's `0x71` data to `self.setup` (re-adding the CRC with `with_crc`), so a read-back sees it. + +```python +def test_s4_dry_run_previews_old_to_new_and_sends_nothing(): # fields == {"geo_trigger_ips": {"label": ..., "old": 0.5, "new": 0.3}}; revision present; fake.executed == [] +def test_s4_trigger_change_sends_the_push_and_verifies(): # subs [0xDA,0x68,0x73,0x82,0x83,0x71,0x72]; outcome sent/ok; state_after "as asked" +def test_s4_stale_revision_sends_nothing(): # SettingsChanged; fake.executed == []; audit has no rows +def test_s4_already_as_asked_is_skipped(): # outcome skipped, nothing executed +def test_s4_monitoring_is_refused(dry_run in (True, False)): # "stop it first" and "nothing sent" +def test_s4_factory_setup_is_refused_live_and_shown_in_preview(): +def test_s4_schedule_conflict_blocks(): # schedule starts "other.mmb" at 07:00 -> ChangeRefused naming other.mmb and 07:00 +def test_s4_schedule_on_the_active_setup_warns_only(): +def test_an_unreadable_schedule_refuses(): +def test_no_schedule_records_is_no_conflict(): # bytes(524) -> sent +def test_s4_a_lost_ack_records_what_the_unit_holds(): # execute_error -> outcome failed, sent True, snapshot present +def test_s4_unseen_block_size_is_blocked(): # prefs 91 B -> preview blocked; live ChangeRefused; nothing executed +def test_setup_push_subs_are_now_enableable(): +``` + +- [ ] **Step 2: Run them.** Expected: FAIL (ImportError: `s4_change_settings`). +- [ ] **Step 3: Implement** the Produces block and update `s4_settings`. In the two opcode tests, swap the over-ceiling example to `0xA8`. +- [ ] **Step 4: Run them**, plus `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`, `tests/test_micromate_writes.py` (THOR's setup-push frames still reproduce) and `tests/test_device_access_s4_call_home.py`. Expected: PASS. +- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s4): change a Micromate's settings by serial, audited, schedule-checked`. + +--- + +### Task 5: The Series 3 settings change + +**Files:** +- Modify: `sfm/device_access/s3.py`, `minimateplus/client.py` (`push_config_raw` pre-check), `tests/device_access_fakes.py` +- Test: `tests/test_device_access_s3_settings.py` (new) + +**Interfaces:** +- Consumes: + - Task 1: `read_compliance_content`, `read_settings_blocks`, `is_compliance_content`. + - Task 2: the codec. + - Task 4: `settings_change`, `SettingsChanged`, `ChangeRefused`. + - `MiniMateClient.push_config_raw(event_index, compliance, trigger, waveform)`. +- Produces: + - `push_config_raw` raises `ImageRefused` (from `minimateplus.protocol`) when its pre-check refuses a block, before any frame. + - `Series3Adapter.settings(address, serial) -> UnitSettings`. It is built on `read_compliance_content` and the codec, with the same top-level fields as today, plus `detail["editable"]`. A non-settings answer raises `UnitStateUnknown(S3_SETTINGS_WHILE_MONITORING)`. + - `S3_SETTINGS_WHILE_MONITORING = "did not return its settings -- a MiniMate answers this way while monitoring; stop monitoring first"`. + - `Series3Adapter.change_settings(address, serial, *, changes, revision, dry_run, audit, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`, through `run_change` and `self._run(address, op, retry=False)`: + - `read_serial`: `client.connect().serial`. + - **`read_state`, first call:** + - Wake, then `read_settings_blocks()`. + - A non-settings `compliance` raises `UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")`. + - `check_changes`, and the live revision check over `[event_index, compliance, trigger, waveform]`. + - Compute `image = encode_setup(...)` and return `settings_state(...)`. + - **Later calls:** wake, `read_compliance_content()`, then the verdict. + - **`describe_plan`:** + - `steps` in Blastware's order: 68 (event index, as read), 73, 71 (settings block, 2,092 B), 72, 82 (trigger, as read), 83, 69 (waveform data, as read), 74, 72. Each step has `sub`, `what` and `data_len`. + - `fields`, `revision` and `warnings` as Series 4. The warning: "the two bytes after the settings block go out as 00 00 (Blastware sends its own constant; effect unmeasured)". + - **`send`:** `client.push_config_raw(event_index, image, trigger, waveform)`. + - **`is_refusal`:** `isinstance(e, ImageRefused)`. + - **`snapshot`:** as Series 4, without prefs and trigger. + +- [ ] **Step 1: Write the failing tests.** Extend `FakeMiniMateClient` with: + - `settings_blocks`: the default compliance is BE9441's assembled 10-26 read 2; `event_index`, `trigger` and `waveform` are the `0x68`, `0x82` and `0x69` payloads (`[16:]`) of `WRITES[13:26]` in `tests/test_minimate_write_frames.py`, each minus its two trailing bytes (a write is the read plus two); + - `push_config_raw` records its four arguments and makes the compliance the new `read_compliance_content`; + - `monitoring_settings=True` returns a device-info-shaped block. + +```python +def test_s3_settings_read_uses_the_codec(): # editable includes geo_range; record_mode "histogram"; notes by slot with unit labels +def test_s3_dry_run_previews_and_sends_nothing(): +def test_s3_trigger_change_sends_the_units_own_blocks(): # push args: event_index/trigger/waveform == the read blocks; compliance == encode_setup(...) +def test_s3_change_verifies_by_read_back(): # outcome sent/ok, state_after "as asked", snapshot fields old/new/now +def test_s3_stale_revision_sends_nothing(): +def test_s3_monitoring_is_refused(dry_run in (True, False)): +def test_s3_a_refused_image_is_audited_as_nothing_sent(): # push_config_raw raises ImageRefused -> row sent 0, "refused before sending" +def test_push_config_raw_precheck_raises_image_refused(): # a 2,089-byte compliance block -> ImageRefused, no frame written +``` + +- [ ] **Step 2: Run them.** Expected: FAIL (AttributeError: `change_settings`). +- [ ] **Step 3: Implement** the Produces block. +- [ ] **Step 4: Run them**, plus `tests/test_s3_call_home.py`, `tests/test_minimate_write_frames.py` and `tests/test_device_access_*`. Expected: PASS, except the tests Task 6 deletes or rewrites. If one fails here only because it pins `apply_config`, leave it for Task 6 and note that in the ledger. +- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s3): change a MiniMate's settings by serial on the shared codec`. + +--- + +### Task 6: Device access, the route, and retiring the legacy write + +**Files:** +- Modify: `sfm/device_access/access.py`, `sfm/server.py`, `minimateplus/client.py` +- Delete: `poc_set_project.py`. Remove `exp_compliance_only` (and its registration) from `experiments.py`. + - **Ruling (spec: "the legacy write is retired"):** both write a live unit through the retired encoder, which #46 found wrong. Git keeps them. +- Modify tests: + - `tests/test_s3_compliance_anchor_fields.py`: remove its write-side tests (the encoder is gone). + - `tests/test_minimate_write_frames.py`: `test_apply_config_writes_the_units_own_trigger_block` moves to Task 5's `test_s3_trigger_change_sends_the_units_own_blocks`; delete it here. + - `tests/test_server_series3_guard.py`: drop `apply_config` from `WRITES` and its fake method. + - `tests/test_server_device_access.py`: `/device/config` now 410. +- Test: `tests/test_device_access_settings.py` (new), `tests/test_server_settings_change.py` (new) + +**Interfaces:** +- Consumes: Task 4's `s4_change_settings` and Task 5's `Series3Adapter.change_settings`. +- Produces: + - `DeviceAccess.change_settings(address, serial, *, changes: dict, revision: Optional[str], dry_run: bool = False, caller: str = "api") -> ChangeResult`: + - `normalise_serial`, then `series_for_serial`; + - `changes` must be a non-empty dict, else `BadRequest`; + - a live call without `revision` raises `BadRequest("preview first: a live change needs the revision from its preview -- nothing sent")`; + - a live call with no audit log raises `NotSupported` (as `set_call_home`); + - `_dispatch(..., change=True)` with `verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S = 2.0` and `verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S = 1.0`. + - `POST /device/settings/change`: + - query: `serial` (required), `host`, `tcp_port`, `port`, `baud`, `dry_run`, `caller`; + - JSON body `{"changes": {...}, "revision": "..."}`; + - returns `_change_response(...)`; + - added to `_SERIAL_AWARE_PATHS`. + - `POST /device/config` and `POST /device/config/project` return **410** with `{"detail": "retired: change a unit's settings by serial with POST /device/settings/change (audited, previewed, read back)"}`. Remove the cache-dirty hooks that only these routes called; keep the read routes. + - Delete `MiniMateClient.apply_config`, `set_project_info` and `_encode_compliance_config`, and any import left orphaned. + +- [ ] **Step 1: Write the failing tests:** + +```python +def test_live_change_without_revision_is_refused_before_io(): # factory never called +def test_empty_changes_is_a_bad_request(): +def test_change_settings_dispatches_by_series_with_change_true(): +def test_route_dry_run_returns_fields_and_revision(): # 200, body.plan.fields, body.plan.revision +def test_route_verified_change_is_200_and_mismatch_409(): +def test_route_unconfirmed_carries_sent_and_audit_id(): +def test_route_refusal_is_409_with_reason(): # ChangeRefused / SettingsChanged / monitoring +def test_legacy_config_routes_are_gone(): # both 410, nothing reaches a client factory +def test_settings_change_is_serial_aware(): # in _SERIAL_AWARE_PATHS; a UM serial goes to the Series-4 path +``` + +- [ ] **Step 2: Run them.** Expected: FAIL (404 / AttributeError). +- [ ] **Step 3: Implement** the Produces block, the deletions, and the test updates listed under Files. +- [ ] **Step 4: Run them**, plus `tests/test_server_*.py`. Expected: PASS. Check that `grep -rn "apply_config\|set_project_info\|_encode_compliance_config" --include=*.py .` finds only comments and history. +- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(sfm): POST /device/settings/change; retire the legacy config write`. + +--- + +### Task 7: The page — edit, preview, send, "the unit now holds" + +**Files:** +- Modify: `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html` +- Modify: `CLAUDE.md` (the "Where things stand" Series-4 parity line: phase 5 built, bench pending), and the spec's status line ("Built 2026-11-xx; bench pending"). +- Test: `tests/test_webapp_device_routing.py` (extend `EXPORTS` and cases), `tests/test_webapp_static.py` + +**Interfaces:** +- Consumes: `UnitSettings.detail.editable` / `.revision`, and the `ChangeResult` shapes from Tasks 4–6. +- Produces (DOM-free, in `device_routing.js`): + - `DEVICE_ROUTES.settings_change = ['POST', '/device/settings/change', true]`; remove `config_write`. + - `controlsFor(unit)`: `configWrite: serialMode && (series === 3 || series === 4)`; `reasons.configWrite: 'By serial only: Preview, then Send (audited).'` + - `settingsFormFields(st) -> Array<{field, label, kind, value, unit?, min?, max?, choices?, maxlength?, readonly?}>`: from `st.detail.editable`, in that order. + - `settingsChanges(fields, edited) -> object`: only fields whose edited value differs. Numbers compare as numbers; read-only fields are ignored. + - `settingsPreviewRows(body) -> Array<[label, old, new]>`, from `body.plan.fields`. + - `settingsBlockedText(body) -> string`: `body.plan.blocked` joined; `''` if none. + - `settingsResultRows(body) -> Array<[label, old, new, now]>`, from `body.detail.snapshot.fields`. +- **Page behaviour** (`sfm_webapp.js` glue; HTML ids `cfg-edit`, `cfg-preview-btn`, `cfg-send-btn`, `cfg-preview`, `cfg-result`): + - The serial-mode Config pane heading reads **"On the unit — read "**. + - The form is built from `settingsFormFields`. + - **Preview** POSTs a dry run and shows old → new, warnings and blocked reasons. It keeps `revision` and enables **Send** only when nothing is blocked and something changes. + - **Send** asks `confirm()` naming the serial and the fields, then POSTs live with the kept revision and shows "the unit now holds" rows. Errors go through `changeErrorText`. + - Editing any field after a preview disables **Send** until the next preview. + - The by-host legacy form loses its write button. Its read stays. + - No inline script; listeners via `addEventListener`. + +- [ ] **Step 1: Write the failing Node-run cases** in `tests/test_webapp_device_routing.py`: + - `controlsFor` gives `configWrite` true by serial for both series, and false by host; + - `settingsChanges` returns only differing fields and compares `0.30` with `0.3` as equal; + - `settingsPreviewRows` / `settingsResultRows` / `settingsBlockedText` on bodies shaped as Task 6 returns them; + - `deviceUrl('settings_change', unit)` → `/device/settings/change?serial=…`; + - `config_write` is no longer a route. + + In `tests/test_webapp_static.py`, assert the page has no inline `