From 7349f5ac00e85d86e655206b0eb6c2512b52715f Mon Sep 17 00:00:00 2001 From: serversdown Date: Mon, 9 Nov 2026 17:25:42 -0500 Subject: [PATCH] docs(spec): monitor logs (.MLG) and each unit's monitoring timeline Design for reading Blastware .MLG files into SFM and deriving each unit's monitoring timeline (sessions, stop reasons, call-ins), for shot reports and outage history. Includes the measured MLG format: length-led 292-byte records with a CRC-16/AUG-CCITT tail (3,329 / 3,329 records). Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1 --- .../2026-11-09-mlg-unit-timeline-design.md | 332 ++++++++++++++++++ 1 file changed, 332 insertions(+) create mode 100644 docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md diff --git a/docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md b/docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md new file mode 100644 index 0000000..3ed1504 --- /dev/null +++ b/docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md @@ -0,0 +1,332 @@ +# Monitor logs (.MLG) and each unit's monitoring timeline — design + +**Date:** 2026-11-09 · **Branch:** `feat/mlg-import` (worktree `~/seismo-relay-mlg`) · +**Status:** design, for review + +## Why this exists + +Every Series-3 unit sends a Blastware monitor log, an `.MLG` file, at every call-in, whatever mode +it is recording in. It lists each time the unit started monitoring, each event, and each time it +stopped and why. Event files cannot replace it: a unit in continuous (waveform) mode sends an event +file only when something triggers, so a quiet day leaves no file at all. + +Brian named two uses (2026-11-09): + +1. **Shot reports.** Every event from every unit on a site goes in the report. A unit that did not + trigger (often the farthest one) is listed as "did not trigger", with its printed `.MLG` + attached as proof it was monitoring at the time of the blast. Example: BE6907 and BE12844 + monitored the same job, June to November 2026, both in continuous mode. BE6907 is much farther + away and recorded 10 events to BE12844's 55. +2. **Outage history.** It is good to know when a unit was not recording, for how long, and why. A + unit on solar and battery can die for a weekend and nobody would notice. Most units keep + recording when they cannot call in; only losing the power and then the internal battery stops + them. So this is history seen once the unit calls in again, not a live alarm. + +The `.MLG` is also what the watcher's heartbeat sniffs today to show that a unit is still calling +in. SFM holding the files would later let it answer that itself. + +## Goals + +1. Read a Blastware `.MLG` into its records, with every record's checksum verified. +2. Accept forwarded `.MLG`s through a new import route, storing each record once. +3. Keep each unit's monitoring timeline, derived from its records: when it was recording, how each + session ended, the events inside, and the call-ins. It must answer two questions: + - was unit X monitoring at time T, and with what trigger level? + - when was it not monitoring, for how long, and why? +4. Serve the records and the timeline through `/db/*`, for Terra-View to use later. +5. Bulk-import a directory of `.MLG`s (DL2 holds about 86,000), and cross-check the records against + the event files' footers. + +## Non-goals + +- **The watcher forwarding `.MLG`s.** That is a change in `../series3-watcher`, Brian's call, and a + separate piece. Until it lands, `.MLG`s reach SFM only through the import route and the bulk tool. +- **Anything in Terra-View:** the timeline view, the shot report, taking "last call-in" from SFM + instead of the heartbeat. Later pieces. +- **Live "missed its call-in" alerts.** A dead unit sends nothing; this timeline shows the gap + once it is back. +- **Series 4.** Thor writes no `.MLG`. +- **Editing the event decoders** (`event_file_io.py`, `decode_check.py`, `histogram_codec.py`, + `waveform_codec.py`). Another session owns them; this project imports from them only. + +## Anti-goals (would make it a failure even if it works) + +- **Claiming monitoring the data does not show.** A session still open at the last call-in is + "running at the last call-in", never "running now". Where a session's end is not recorded, the + timeline says so and gives the window it lies in. +- **Dropping a damaged file or record silently.** A record that fails its checksum is reported, + never half-read into the timeline. +- **Taking the serial from the file name when the file carries it.** Names are `` + with nothing between, so `BE11010304` cannot be split by reading it. +- **Mixing clocks.** Record times are the unit's own local clock. File times are the PC's. They are + stored and labelled separately. + +## What was measured + +Grades: **measured** means checked on the files named; **inferred** means a reading of them that +has not been tested. + +**Files examined:** 1,273 `.MLG`s from DL2's `C:\Blastware 10\Event\autocall home` (BE6907 369 and +BE12844 197, from 2026; BE8081 707, 2018–19), in `~/dl2-archive/mlg/`. Also the 9 bench files in +`example-events/`. Analysis scripts used for this section are in the session scratchpad and are +not part of the build. + +### The file format (measured on all 1,282 files) + +- **Layout:** an 18-byte prefix `10 00 01 80 00 00 "Instantel\0" 07 2c`, then whole 292-byte + records. The size is always `18 + 292·n`. +- **Every record** is `[length uint16 LE = 0x0122 (290)][id 2 bytes] … [CRC 2 bytes]`. Id `0e a0` is + the header record (one, first, carrying the serial). Id `0e 80` is a log record. +- **Checksum:** CRC-16/AUG-CCITT (poly 0x1021, init 0x1D0F, no reflection) over the record's bytes + `[0:288]`, stored little-endian at `[290:292]`. Bytes `[288:290]` are `00 00` and not covered. + This is the rule the Micromate setup blocks use (`micromate.setup_block`). It matches **3,329 of + 3,329** records, with no failures. + - The reference (D.4.2) put a CRC at the *start* of each record. That was the previous record's + tail, which is also why every file had 2 unexplained bytes at its end. +- **A log record** (offsets from its length field): + +| offset | field | +|---|---| +| `[4:12]` | start: day, month, year **LE**, 0, hour, min, sec | +| `[12:20]` | stop, same format; all zeros = no stop | +| `[20:22]` | monitor-log flag word, uint16 LE: the same word as the event footer's (D.6.14) | +| `[22:24]` | trigger source, uint16 LE: `0x0001`–`0x0008` a channel, `0x0400` a histogram | +| `[24:34]` | serial, null-padded ASCII | +| `[34:…]` | text, null-padded (below) | + +- **Text:** + - a "monitoring started" record: `Trigger Level : Geo: 0.0500 in/s Mic: 125.0 dB(L)`, or + `Trigger Level : Histogram` + - an event record: `08`, then the event time in 8 bytes (LE year), then + `Geo: 0.0500 in/s Mic: 125.0 dB(L)` + - a closed session: `Geo: 0.0500 in/s Mic: 125.0 dB(L)` +- **Empty files:** some files are the 18-byte prefix alone, with no records and so no serial inside. + +### How Blastware writes them (measured on the 3 DL2 units) + +- **One file per call-in**, named `.MLG`, the counter going up by one each time. +- **No record appears in two files.** Each holds what happened since the previous call-in. +- **A file is written 1–2 minutes after the unit stops for its call-in** ("Modem Exit"). The unit's + clock and DL2's agree to within those 2 minutes. + - ⚠ Dates of files that came through a Windows zip read an hour early from March to October. + Windows converts with the offset in force at zip time, not the one at the file's date. A + robocopy copy keeps the true time. +- **BE6907 writes two empty files 2–3 minutes after nearly every real one** (230 of its 369). + BE12844 and BE8081 never do. Inferred: the unit calls back in and has nothing new. +- **Some files hold more than one Modem Exit:** 38 files (BE8081 33, BE6907 3, BE12844 2). A + file is written just after its *last* Modem Exit. The earlier ones are calls that left no file. + Example: `BE8081321` holds Modem Exits on 2019-04-12 18:33, 04-13 07:00 and 04-15 17:15. + - Inferred: the call failed, or the PC did not take it. + - Either way, this is the "missed call-in" history Brian asked about. +- **The unit's clock steps back an hour at the first call-in after daylight saving ends.** On + 2026-11-01 BE12844 ran `06:00:13 → 18:45:00` (unit still on EDT). It called in at 17:46 EST, + and its next session is `17:47:25 → 18:45:00`. BE6907 shows the same. So local times on that day + overlap. Inferred: Blastware sets the unit's clock at the call-in, and in spring the clock + steps forward the same way. +- **Blastware writes the text, not the unit.** The two bench copies of the same records + (`ach-vs-manual/BE11529.MLG`, `BE115292.MLG`) differ only in `Trigger Level: Histogram` vs + `Trigger Level : Histogram`. A record's identity must not include its text or its checksum. +- **Cable or direct downloads are cumulative.** The bench `4-3-26-multi/BE11529.MLG` repeats the + 4-1 records. Only the call-in files hold "only what is new". + +### How a session appears (measured on the 3 DL2 units) + +- **A session with no events** is one closed record: start, stop and why it stopped. BE12844's day: + `06:00:13 → 18:45:00` "Modem Exit" (its call-in), then `18:47 → 20:00` "Timer Stop" (a + work-hours timer). +- **A session with events** is an open "monitoring started" record (flag word `ffff`, no stop), + then one record per event (`0x0001` + the channel). The unit calls in minutes after each event, + and monitoring resumes as a *new* session minutes later. Example, BE12844 on 9-8: + - `06:00:13` started, then an event `13:38:22 → 13:38:25` (Tran) + - a file written about a minute later + - next file: `13:41:16 → 18:45:00` "Modem Exit" + + The first session's end is not written anywhere. It lies between the last event's stop and the + next session's start (inferred: the call-in after the event ended it). +- **A histogram session** is a "monitoring started" record at T, then a histogram record from T+1 s + to the stop, carrying the stop reason (`0x0021` = Event Recorded + Modem Exit, source `0x0400`). +- **A histogram + waveform session** also has waveform event records whose start falls inside the + histogram record's span (BE8081, 5 in 2018). Example: histogram `15:15:32 → 15:15:49`, with a + Vert event `15:15:47 → 15:15:49`. Its trigger-level text says only "Histogram". The geophone + level appears only on its event records. + +### Cross-check against the event files (measured) + +Each "Event Recorded" record was matched to DL2's event files by **stop time + flag word + trigger +source**: + +- **BE8081:** 785 / 785 records match an event file, and all 785 of its DL2 event files in that + period have a record. 714 histogram footers start exactly at the session's "monitoring started" + record; the other 71 start where the record does. +- **BE6907 / BE12844:** 25 / 25 event files have a record. The 42 records with no file all stop + after 2026-08-25, where the DL2 copy ends. +- On 2026-08-27 both units triggered at 13:00:42 / 13:00:43, the same blast. + +## Design + +### 1. The reader (codec library: pure, no I/O beyond the file) + +`read_mlg(path)` replaces the stub in `minimateplus/blastware_file.py` and returns a new model +(`MlgFile`, `MlgRecord` in `models.py`). It does not reuse `MonitorLogEntry`, which is the live +0x0A shape. Per record: + +- start, stop (None when open), flag word, trigger source +- Blastware's words, from `event_file_io.monitor_log_description()` (imported, not copied) +- the text, plus the trigger level and the event time parsed from it +- whether the checksum passed + +Per file: the serial (from the header record; None for an empty file), the records, whether the +file is whole. A file whose size is not `18 + 292·n`, or with a bad prefix, raises. A record that +fails its checksum is returned flagged; the caller decides. + +### 2. `write_mlg()` (last, small) + +Fix it to write what Blastware writes: little-endian times, the length-led framing and the CRC. +Test: rebuild bench and DL2 files byte for byte from what the reader returns. If the header +record's unread bytes stop that, say so and leave the writer as it is. + +### 3. Storage (`sfm/database.py`) + +- **The original file is kept, byte for byte,** in the waveform store beside the unit's event + files. Files are tiny (18 bytes to a few KB). It is the shot-report proof, and Blastware can + open and print it. Rows alone cannot rebuild it, because Blastware's text varies. +- **`mlg_files`:** one row per file received: + - serial, file name, size, SHA-256, record count, an empty flag + - received time, and the file's modified time (UTC, when the sender gives it) + - whether it is a call-in file (default yes; a cable download is not) + + The same name with the same bytes is a re-send and is skipped. Empty files all share one + hash, so the name keeps them apart. Some names have no counter (`BE8081.MLG` was DL2's first), + so name alone is not enough. This table is the call-in history, and the only trace of an empty + file. +- **`mlg_records`:** one row per log record: serial, start, stop, flag word, trigger source, text, + and the file it first came in. Stored once: + - unique on `(serial, start, stop, flag word, trigger source)` + - ⚠ an open record's stop is NULL, and SQLite treats NULLs as distinct in a UNIQUE constraint. + The key must handle that, for example with an index on `COALESCE(stop, '')`. +- **The existing `monitor_log` table is left alone.** It holds live 0x0A rows from + `bridges/ach_server.py`, which is not in production. A future SFM call-in server would write + `.MLG`-shaped records into `mlg_records` instead. + +### 4. The timeline (computed when asked, not stored) + +From a unit's records in time order: + +- **A closed record** with no event bit is a session `[start, stop]`, ended for its reason. +- **A histogram record** is a session from its "monitoring started" record (or its own start, when + there is none) to its stop, ended for its reason. +- **A "monitoring started" record followed by events** is a session from that start. Its end is + "between the last event's stop and the next session's start". +- **A "monitoring started" record with nothing after it yet** is "running at the last call-in". + +Gaps between sessions take the reason the previous session ended with: + +| previous session ended with | the gap means | +|---|---| +| Modem Exit | a call-in | +| Timer Stop | scheduled off | +| Battery Low Exit | lost power | +| Keyboard Exit / Remote Exit | stopped by a person | +| Memory Full Exit | memory full | +| none known | unknown | + +- **Waveform events inside a histogram session** belong to that session. They are not sessions + of their own. +- **Trigger level is reported as logged:** the session's text, plus any geophone level its event + records carry. It is never borrowed from a neighbouring session. A histogram session with no + events says "Histogram", geophone level not logged. +- **Clock steps:** a session that starts before the previous one stopped is a clock step, not an + overlap. The timeline shows it as such, with no negative gap. Times are the unit's local clock, + as SFM's event times are; `at`, `from_dt` and `to_dt` are in that clock. If `at` falls in a + repeated hour and matches two sessions, `monitoring_at` returns both and says so. The spring + step forward will show as a gap an hour too long on that one day; that is accepted. + +**Call-ins** are listed by the call each file came from: + +- **Delivered:** a call-in file's last Modem Exit (unit clock), paired with the file (PC clock). +- **No file:** the earlier Modem Exits in the same file. Calls that left no file. +- **Nothing new:** an empty file, at its file time. + +Cable-download files are not call-ins. + +### 5. Routes (`sfm/server.py`) + +- `POST /db/import/mlg_file`: one or more files, an optional serial hint, each file's modified + time when the sender has it, and `call_in` (default true). + - Mirrors `/db/import/blastware_file`: each file gets its own status, and good files are stored + even when another in the same request is not. + - Per file it returns the serial, records inserted and skipped, and whether it was empty. + - A file with any failed checksum, or that is not whole, stores nothing of itself. Its status + names the record. +- `GET /db/mlg_files/{id}`: the original file, for printing or opening in Blastware. +- `GET /db/units/{serial}/timeline?from_dt=&to_dt=`: sessions (start, end or end window, how it + ended, its events, its trigger level), gaps with their meaning, and call-ins. +- `GET /db/units/{serial}/monitoring_at?at=`: `monitoring` / `not_monitoring` / `unknown`, with the + session and records that say so, and the trigger level. This is the shot report's question. +- `GET /db/mlg_records?serial=&from_dt=&to_dt=`: the raw records. + +### 6. Serial of an empty file + +An empty file holds no serial. Take, in order: + +1. the request's serial hint +2. the longest serial SFM already knows (units, events, `.MLG` headers) that the name starts with +3. otherwise store the file with no serial and report it as unresolved + +### 7. Tools + +- **`scripts/import_mlg_dir.py `:** imports a directory tree of `.MLG`s straight into the DB, + with a dry run that prints the counts. Same pattern as the backfill scripts. For DL2's ~86,000. + - Every file it reads is a call-in file (it is pointed at the ACH folder's copy). + - It records file times as found, but they matter only for empty files. A zipped copy's times + are an hour early from March to October. + - The full DL2 import should come from a robocopy copy, which keeps true times. +- **`scratch/check_mlg_vs_events.py `:** the cross-check above, in both + directions, for the whole archive. + +### 8. Documentation + +- Rewrite the reference's D.4 (`docs/instantel_protocol_reference.md`) with the measured framing, + checksum, fields and file behaviour, keeping the old text as a retraction. Mark D.4.3 solved. + The file is CRLF: edit it with the Edit tool. +- 🔑 **For Brian to pass to the decoder session, not edited here:** the event-file footer's + checksum (D.3.3, open since April) is the same rule. AUG-CCITT over the footer record from its + length `00 1a` through byte 24, stored big-endian. It matches **70,041 / 70,041** DL2 files. + Inferred: every record in the event file's tail chain (D.6.13) carries one. + +## Testing + +TDD. Fixtures go in a dated `tests/fixtures/` directory (force-added if ignored). A small set +covering each shape: + +- a closed-records day (BE12844) +- a session with an event (BE12844 #3067–#3068) +- a histogram day (BE8081) +- a Battery Low Exit (BE8081) +- an empty 18-byte file (BE6907) +- a file with calls that left no file (`BE8081321`) +- the clock step back (BE12844 #3155–#3156) +- a histogram + waveform session (`BE8081.MLG`, 2018-02-16) +- the 4 bench files, including the `ach-vs-manual` pair whose text differs + +Plus one file with a byte flipped, for the checksum. + +The reader, the storage (including that an open record imported twice is stored once), the +timeline cases above and the routes each get tests. The full suite has 16 known failures; read the +failure list before committing. + +## Left to the builder + +- Model and helper names; the exact JSON shapes of the routes. +- Whether `read_mlg` moves into its own module later. +- What the header record's other bytes hold (all zero on the files seen). +- **Not in this project:** linking a session's events to SFM's stored event ids. Terra-View may + want that later. It needs a matcher, because the events table stores neither the stop time nor + the flag word, and its times moved in 0.32.0 and 0.34.0. + +## Later pieces (not this project) + +- **The watcher** forwards `.MLG`s with their modified time, and the heartbeat stops sniffing them. +- **Terra-View** shows each unit's timeline, puts "monitoring during the blast" on shot reports, + and takes "last call-in" from SFM. +- **BE6907's extra call-ins:** worth a look at its modem and call-home settings.