From 75a1d135ee213fab455ae2980f8ba39830dd7baf Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 4 Nov 2026 16:29:07 -0500 Subject: [PATCH] docs(changelog): Unreleased -- Series-4 parity in SFM (phases 1-5) Everything by serial for both series, the audited changes (start/stop, call-home, settings), the MiniMate wire fixes (#46, the 64 KB page, the settings read as content), the legacy config write retired, the benches. Operational: additive schema only (device_commands), no TOOL_VERSION bump, no backfill from this branch. Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44 --- CHANGELOG.md | 100 +++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 100 insertions(+) diff --git a/CHANGELOG.md b/CHANGELOG.md index 2763c69..6e6c4ff 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -7,6 +7,36 @@ All notable changes to seismo-relay are documented here. ## Unreleased ### Fixed +- ✅ **MiniMate requests and config writes are framed as Blastware frames them + (#46; `feat/series4-sfm-parity`).** + - Every request escapes 02 / 03 / 04 / 10. + - A config write is an ordinary escaped request carrying a whole block (as + read, plus two bytes). All four blocks are checked before the first frame. + - SFM's frames equal Blastware's in the 2026-04-20 and 2026-10-26 captures. + Benched on BE9441 2026-11-04. +- ✅ **The 5A walk crosses a unit's 64 KB page.** The walk is 32-bit linear + (the CLAUDE.md "KNOWN BUG"); BE9441's page-crossing events rebuild Blastware's + own files byte for byte. + - A one-event download is whole or an error. + - A non-first event's stream has no metadata pages. +- **A MiniMate settings read is assembled as content** (measured at the bench + 2026-11-04). + - Unescape each 1A frame and drop the one non-content byte that starts every + frame but the last: 2,090 bytes headed by N = 2090. + - The read takes exactly the length it asked for. When a reply's checksum + byte is itself escaped (about 1 frame in 85), the parser leaves its 0x10 in + the data. It hit the first live read; the recordings never had it. The + waveform-data read now trims it too. +- **A live download is held to its record type (#51):** a same-second + waveform / histogram twin is no longer skipped as "already stored". An untyped + row at that second still counts as stored. +- Smaller wire fixes from the parity benches: + - SUB 0x15's serial is cut at its first NUL. + - 0x1C reads a histogram run as monitoring. + - A MiniMate that boots on connect is waited for. + - A start's read-back waits out the sensor check and wakes the unit. + - A built call-home image is framed once. + - ✅ **#51: events are identified by unit + time + type, and histograms take Blastware's times.** - **The new key.** The events table was `UNIQUE(serial, timestamp)`, one @@ -135,6 +165,59 @@ All notable changes to seismo-relay are documented here. change. ### Added +- **Series-4 parity in SFM: everything by serial, for both series** + (`feat/series4-sfm-parity`, merged 2026-11-04; spec + `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`). + - **One door, `DeviceAccess`.** + - A unit is addressed by its serial: UM is Series 4, BE / BA is Series 3. + The unit's own answer is checked before anything is sent. + - A Micromate's line is held between requests and released when idle or + on RADIO RING. + - One connection per unit; 423 while busy. + - **Reads, both series:** `GET /device/info`, `/device/monitor/status`, + `/device/settings`, `/device/events` and `POST /device/events/download`. + - A download is stored as the watcher stores it, through the Blastware / + IDF import path, typed. + - It never overwrites a stored event. + - SFM's MiniMate files carry Blastware's W/H type letter. + - **Changes, both series, each audited** (a `device_commands` row per + attempt), identity-checked, sent once, never retried, read back: + - start / stop monitoring; + - call-home on / off: `GET /device/call_home/state`, + `POST /device/call_home/{enable,disable}`; + - **settings**, `POST /device/settings/change`. + - **Settings, in detail:** + - A preview (dry run) shows old → new and returns a revision; a live + change must carry it, covering the unit's block and the changes asked for. + - Fields: record mode, sample rate, histogram interval, record time, + geophone trigger, the four notes, job number and its report flag, and + (MiniMate) range and alarm. + - Limits are the units' own, from Instantel's manuals, checked on the + block that would result. + - Refused before anything is sent: a monitoring unit, a stale preview, a + Micromate on its factory setup, or one whose schedule would load another + setup. SFM reads `schedule.dat`, read-only. + - **One settings codec for both series** (`micromate/setup_fields.py`): a + MiniMate's settings block is Series IV's `0x1A` layout. All 11 Blastware + compliance writes reproduce from the block before them. + - **The page:** + - units by serial, with the series badge from the unit's own answer; + - the events list and download, start / stop, the Call Home tab; + - the Config tab's Preview → Send → "the unit now holds"; + - page JavaScript in `sfm/static/`, tested through Node (no inline JS). + - **Benched on BE9441 and UM20147:** phase 4 on 2026-11-03, phase 5 on + 2026-11-04. Every change was acknowledged, read back and confirmed on the + unit's screen; both units were restored byte for byte. + - ⚠ A MiniMate's open setup menu loses a remote change when the operator + presses Cancel or Save (the menu writes its whole-block copy back). The + preview warns. + - ⚠ The Micromate scheduler switch is in no block SFM reads, so a leftover + schedule blocks a change even with the scheduler Off. + - ⚠ **Operational:** additive schema only. SFM creates `device_commands`, or + adds `sent` / `states` to an older one, on first start; this branch does not + touch `events`. No `TOOL_VERSION` bump and no backfill from this branch: + event decoding is unchanged. Production ingest (the watchers) is untouched; + the new device routes are used only from SFM's page and API. - **A histogram's interval detail: frequencies, vector sums, interval size and stop** (group B of the file-only decode). Measured on DL2 2026-11-03. - **Frequency** = (sample rate / 2) / half-period: 527,915 / 527,915 cells @@ -226,7 +309,24 @@ All notable changes to seismo-relay are documented here. backfill (`backfill_sidecars.py` then `backfill_event_shape.py`). The new `.h5` attributes are additive. No schema change, no migration. +### Removed +- **`POST /device/config` and `POST /device/config/project` answer 410**, + pointing at `POST /device/settings/change`. Terra-View does not call them. + Removed with them, because they wrote a live unit through the encoder #46 + found wrong: + - `MiniMateClient.apply_config`, `set_project_info` and + `_encode_compliance_config`; + - `poc_set_project.py`, and `experiments.py`'s EXP6. + ### Protocol / Documentation +- **The parity benches in both protocol references:** + - Series III: the settings write measured end to end, the escaped-checksum + stray byte, the keypad menu writing its whole-block copy back, the alarm at + channel +38, and `[26:28]` re-set while monitoring. + - Series IV: the first setup push, with the unit's CRC equal to SFM's; the + schedule read on a real unit; the scheduler switch in none of the blocks. + - Spec and plan: `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md`, + `docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md`. - **Histogram timing in the protocol reference (D.6.10):** - the histogram's own event record - the interval-time and peak-time rules