diff --git a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md index c72d3a1..8d2a104 100644 --- a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md +++ b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md @@ -681,7 +681,9 @@ a short plan; #14 waits for the line-hold decision above. 4. List vector sum 0 / −0 for three events whose peaks reach 1.08 in/s -- suspected escapes in the `0C` record (not checked). 5. Stored S3 event: client "Terra-Mechanic" (last letter missing) -- unexplained. -6. Page: the Config tab shows the empty write form until Read in serial mode. +6. ✅ **Fixed 2026-11-02 (Batch 2):** by serial the edit form stays hidden and the settings + box shows from the start ("Not read yet"); another unit's settings are cleared. + Page: the Config tab shows the empty write form until Read in serial mode. 7. `/db/events` 500 "database is locked" on the first page load against a new DB. 8. ✅ **Fixed `9492e49`**, plus `3a1d34a` ("already stored" also matches the Blastware name: a histogram's row sits a second off its 0C time). The download carries the assembled Blastware file and is @@ -704,10 +706,14 @@ a short plan; #14 waits for the line-hold decision above. **S3 start over a modem:** the line dropped during the sensor check, the read-back hit `Broken pipe` and did not reconnect → 503 though the start worked. Fix: reconnect for the read-back (reads only; the send stays single). -10. Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording. +10. ✅ **Fixed 2026-11-02 (Batch 2):** the start/stop route adds `sent` + `audit_id` to a + ChangeUnconfirmed (same status and message); the page says "… not confirmed:". + Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording. 11. S3 stop ~19 s, 11.6 s of it the identity check (a full connect) vs ~1 s for a serial-only read. **Identified only** (speed is secondary to reliability). -12. Page, serial mode: the Device tab's empty legacy compliance table; S4 +12. ✅ **Fixed 2026-11-02 (Batch 2):** by serial the legacy tables are hidden behind a + pointer to the Config tab; a Micromate's Firmware reads "Thor line (version not read)". + Page, serial mode: the Device tab's empty legacy compliance table; S4 Firmware "—" (should say Thor line). 13. S4 mic in the event's peaks "0.0 dBL" vs 96.54 dB(L) in the file -- the `0x0C` mic denormal parked above, now visible. @@ -717,7 +723,10 @@ a short plan; #14 waits for the line-hold decision above. **RETRACTED 2026-10-29: not a bug.** `sent` is documented as 1 acknowledged, 0 nothing sent, NULL unknown (`sfm/database.py`, `change.py`); a frame answered by a ring instead of its ack is exactly unknown, and the row's `error` says it was sent. -16. Page: a 504 on a unit THOR holds should say "connected, but no reply -- +16. ✅ **Fixed 2026-11-02 (Batch 2):** a 504 with nothing sent adds "the connection opened, + so the modem is reachable — another program (THOR or Blastware) may be holding + this unit's line, or the unit is busy". + Page: a 504 on a unit THOR holds should say "connected, but no reply -- another program may be holding this unit's line". 17. ✅ **Range part fixed 2026-11-02:** a MiniMate downloaded *while monitoring* answers 1A with its device-info block, so no range was read and the stored diff --git a/sfm/server.py b/sfm/server.py index 1ce3b37..c1b5ae3 100644 --- a/sfm/server.py +++ b/sfm/server.py @@ -86,7 +86,7 @@ from sfm import db_snapshot from sfm.event_ingest import backfill_series3_event, persist_download import dataclasses from sfm.device_access import DeviceAccess, DeviceError, UnitAddress -from sfm.device_access.errors import BadRequest +from sfm.device_access.errors import BadRequest, ChangeUnconfirmed from sfm.device_access.series import normalise_serial, series_for_serial from sfm.audit import DbAudit @@ -400,9 +400,20 @@ def _via_device_access(fn) -> dict: def _change_response(fn) -> JSONResponse: """Run a start/stop; the ChangeResult is the body, its outcome picks the status. - DeviceError mapping is _via_device_access's -- not repeated here. + DeviceError mapping is _via_device_access's -- not repeated here. A change + that went out, or may have (ChangeUnconfirmed), keeps that status and message + and adds `sent` ("acknowledged" / "unknown") and `audit_id`, so a client can + tell it from a failure that sent nothing without matching the wording + (bench finding #10, 2026-11-02). """ - body = _via_device_access(fn) + try: + body = _via_device_access(fn) + except HTTPException as exc: + cause = exc.__cause__ + if not isinstance(cause, ChangeUnconfirmed): + raise + return JSONResponse(status_code=exc.status_code, + content={"detail": exc.detail, "sent": cause.sent, "audit_id": cause.audit_id}) # An allow-list: only a dry run, a skip, or a change read back as made is a 200. ok = (body["outcome"] in ("dry_run", "skipped") or (body["outcome"] == "sent" and body["verified"] == "ok")) diff --git a/sfm/sfm_webapp.html b/sfm/sfm_webapp.html index ab442e8..31e420c 100644 --- a/sfm/sfm_webapp.html +++ b/sfm/sfm_webapp.html @@ -952,11 +952,14 @@
-
Compliance Config
-
+ +
+
Compliance Config
+
-
Project Info
-
+
Project Info
+
+
diff --git a/sfm/static/device_routing.js b/sfm/static/device_routing.js index ac1f0cd..512d066 100644 --- a/sfm/static/device_routing.js +++ b/sfm/static/device_routing.js @@ -154,4 +154,42 @@ function downloadSummary(body) { if (body.inserted === false) return `already stored — ${body.stored_filename}`; return `stored ${body.stored_filename}, ${body.filesize} bytes, check: ${(body.detail || {}).check}`; } + +// A Micromate's version string lives in 0x01, undecoded; which firmware line it +// runs comes free with every reply (bench finding #12). +const FIRMWARE_LINES = { thor: 'Thor line (version not read)', blastware: 'Blastware line (version not read)' }; +function firmwareLabel(info) { + const i = info || {}; + return i.firmware_version || i.firmware || FIRMWARE_LINES[(i.detail || {}).firmware_line] || '—'; +} + +// A failed device request's message. A 504 is a unit that took the connection +// but never answered: while THOR polls a Micromate, SFM's connection is accepted +// and gets 0 bytes (measured 2026-10-29, bench finding #16). The hint is left +// off once a change was sent -- its own message says what happened. +const NO_REPLY_HINT = 'the connection opened, so the modem is reachable — another program (THOR or ' + + "Blastware) may be holding this unit's line, or the unit is busy (e.g. its sensor check)"; +function errorDetail(body, statusText) { + const b = body || {}, d = b.detail; + return b.outcome ? changeSummary(b) : typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : statusText; +} +function deviceErrorText(status, body, unit, statusText) { + const text = errorDetail(body, statusText); + return status === 504 && !(body || {}).sent && unit && unit.host ? `${text} — ${NO_REPLY_HINT}` : text; +} + +// A start/stop that went out (or may have) is not "failed": its body carries +// `sent` (ChangeUnconfirmed, bench finding #10), and its message says what the +// unit did and names the audit record. +function changeErrorText(verb, status, body, unit, statusText) { + if ((body || {}).sent) return `${verb} monitoring not confirmed: ${errorDetail(body, statusText)}`; + return `${verb} monitoring failed: ${deviceErrorText(status, body, unit, statusText)}`; +} + +// By serial, settings are read-only until phase 5: no empty legacy edit form or +// legacy tables, and the settings box shows from the start (#6, #12). +function serialPanes(bySerial, settingsRead) { + return { configForm: !bySerial, settingsBox: bySerial, settingsPlaceholder: bySerial && !settingsRead, + legacyDeviceTables: !bySerial }; +} /* */ diff --git a/sfm/static/sfm_webapp.js b/sfm/static/sfm_webapp.js index 91ee01d..0697cdd 100644 --- a/sfm/static/sfm_webapp.js +++ b/sfm/static/sfm_webapp.js @@ -73,9 +73,7 @@ async function deviceFetch(action, params = {}, opts = {}) { const r = await deviceRequest(action, params, opts); const body = await r.json().catch(() => ({})); if (!r.ok) { - const d = body.detail; - const err = new Error(body.outcome ? changeSummary(body) - : typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : r.statusText); + const err = new Error(deviceErrorText(r.status, body, currentUnit(), r.statusText)); err.status = r.status; err.body = body; throw err; } @@ -102,6 +100,22 @@ function applyControls() { chr.title = s4; document.getElementById('ch-series-note').textContent = s4; setMonitorButtons(); + applyConfigPanes(); +} + +// The Config tab by serial (#6): settings are read-only until phase 5, so the +// empty legacy edit form stays hidden and the settings box shows from the start. +// A different unit's settings are never left on screen. +let settingsShownFor = null; +function applyConfigPanes() { + const serial = normSerial(currentUnit().serial); + const p = serialPanes(Boolean(serial), Boolean(serial) && settingsShownFor === serial); + document.getElementById('cfg-form').style.display = p.configForm ? '' : 'none'; + document.getElementById('cfg-settings').style.display = p.settingsBox ? 'block' : 'none'; + if (p.settingsPlaceholder) { + settingsShownFor = null; + renderTextTable('cfg-settings-table', [['Settings', 'Not read yet — press Read from Device']]); + } } async function hangUp() { @@ -430,8 +444,7 @@ async function changeMonitoring(action) { if (body.outcome) { setStatus(changeSummary(body), r.ok ? 'ok' : 'error'); } else { - const d = body.detail; - setStatus(`${verb} monitoring failed: ${typeof d === 'string' ? d : d ? JSON.stringify(d) : r.statusText}`, 'error'); + setStatus(changeErrorText(verb, r.status, body, currentUnit(), r.statusText), 'error'); } } catch (e) { // No reply is not "nothing sent": the request may have reached the unit. @@ -454,7 +467,7 @@ function populateDeviceTab() { const cardData = [ { label:'Serial Number', value: unitInfo.serial || '—' }, { label:'Series', value: confirmedSeries(currentUnit()) ?? '—' }, - { label:'Firmware', value: unitInfo.firmware_version || unitInfo.firmware || '—' }, + { label:'Firmware', value: firmwareLabel(unitInfo) }, { label:'DSP', value: unitInfo.dsp_version || (unitInfo.detail || {}).dsp_version || '—' }, { label:'Model', value: unitInfo.model || '—' }, { label:'Manufacturer', value: unitInfo.manufacturer || (unitInfo.detail || {}).manufacturer || '—' }, @@ -471,6 +484,11 @@ function populateDeviceTab() { cards.appendChild(c); } + // The legacy settings tables are empty by serial (#12); the Config tab reads them. + const legacy = serialPanes(serialMode(), false).legacyDeviceTables; + document.getElementById('dev-legacy-tables').hidden = !legacy; + document.getElementById('dev-serial-note').hidden = legacy; + // Compliance table const cc = unitInfo.compliance_config || {}; const RECORDING_MODE_LABELS = {0: 'Single Shot', 1: 'Continuous', 3: 'Histogram', 4: 'Histogram + Continuous'}; @@ -713,6 +731,7 @@ async function readSettingsBySerial() { try { const st = await deviceFetch('settings'); renderTextTable('cfg-settings-table', settingsRows(st)); + settingsShownFor = normSerial(st.serial); document.getElementById('cfg-settings').style.display = 'block'; document.getElementById('cfg-form').style.display = 'none'; setCfgStatus(`Settings read from ${st.serial}.`, 'ok'); diff --git a/tests/test_server_device_access.py b/tests/test_server_device_access.py index 93bd2f3..08aaedb 100644 --- a/tests/test_server_device_access.py +++ b/tests/test_server_device_access.py @@ -2,6 +2,8 @@ FastAPI Query() defaults are FieldInfo objects, not values.""" from __future__ import annotations +import json + import os import sys @@ -418,10 +420,13 @@ def test_a_change_unconfirmed_keeps_its_cause_status_and_names_the_audit_record( "failed: silent -- audit record c7", audit_id="c7", sent="acknowledged", http_status=504) monkeypatch.setattr(srv, "_device_access_instance", Raises()) - with pytest.raises(HTTPException) as e: - srv.device_monitor_start(**CH) - assert e.value.status_code == 504 - assert "audit record c7" in e.value.detail + resp = srv.device_monitor_start(**CH) + assert resp.status_code == 504 # the cause's status, unchanged + body = json.loads(resp.body) + assert "audit record c7" in body["detail"] + # #10 (2026-11-02): the page tells "may have been sent" from "nothing sent" by + # these, not by matching the message. + assert (body["sent"], body["audit_id"]) == ("acknowledged", "c7") def test_device_commands_normalises_the_serial(tmp_path, monkeypatch): diff --git a/tests/test_webapp_device_routing.py b/tests/test_webapp_device_routing.py index 2110ea4..9686eba 100644 --- a/tests/test_webapp_device_routing.py +++ b/tests/test_webapp_device_routing.py @@ -28,7 +28,7 @@ NODE = shutil.which("node") pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the page-logic tests need it") EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows", "perIndexLive", "escapeHtml", - "changeSummary", "downloadSummary"] + "changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes"] def _block() -> str: @@ -234,3 +234,59 @@ def test_the_per_index_routes_follow_the_list_not_the_keyboard(): def test_escape_html_makes_a_unit_string_inert(): r = run(["escapeHtml", ['Bench &\'']], ["escapeHtml", [None]], ["escapeHtml", [42]]) assert r == ["Bench <b id="x">&'", "", "42"] + + + +# ── Batch 2 (1c bench polish, 2026-11-02) ───────────────────────────────────── + +def test_firmware_label_says_which_line_a_micromate_runs(): + # #12: a Micromate's version string is in 0x01, undecoded; its firmware line is known. + r = run(["firmwareLabel", [{"firmware": "S338.17"}]], ["firmwareLabel", [{"firmware_version": "S338.17"}]], + ["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "thor"}}]], + ["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "blastware"}}]], + ["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "unknown"}}]], + ["firmwareLabel", [{}]], ["firmwareLabel", [None]]) + assert r == ["S338.17", "S338.17", "Thor line (version not read)", "Blastware line (version not read)", + "—", "—", "—"] + + +HINT = ("the connection opened, so the modem is reachable — another program (THOR or Blastware) may be " + "holding this unit's line, or the unit is busy (e.g. its sensor check)") + + +def test_a_504_says_another_program_may_hold_the_line(): + # #16: measured 2026-10-29 -- while THOR polls a Micromate, SFM's connection is + # accepted and gets 0 bytes, a 504. The hint is not added once a change was sent. + silent = {"detail": "the unit did not answer: no reply"} + sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x " + "-- audit record c7", "sent": "acknowledged", "audit_id": "c7"} + r = run(["deviceErrorText", [504, silent, S4, "HTTP 504"]], ["deviceErrorText", [504, sent, S4, "HTTP 504"]], + ["deviceErrorText", [503, {"detail": "could not connect: refused"}, S4, "HTTP 503"]], + ["deviceErrorText", [504, silent, {"serial": "UM20147", "host": "", "tcpPort": 9034}, "HTTP 504"]], + ["deviceErrorText", [502, {}, S4, "HTTP 502"]]) + assert r == [f"the unit did not answer: no reply — {HINT}", sent["detail"], "could not connect: refused", + "the unit did not answer: no reply", "HTTP 502"] + + +def test_a_change_that_was_sent_is_not_called_failed(): + # #10: a ChangeUnconfirmed body carries `sent`; anything else is a real failure. + sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x " + "-- audit record c7", "sent": "acknowledged", "audit_id": "c7"} + r = run(["changeErrorText", ["Start", 504, sent, S3, "HTTP 504"]], + ["changeErrorText", ["Stop", 503, {**sent, "sent": "unknown"}, S3, "HTTP 503"]], + ["changeErrorText", ["Start", 504, {"detail": "the unit did not answer: no reply"}, S3, "HTTP 504"]], + ["changeErrorText", ["Stop", 409, {"detail": "not BE9441: BE12599 answered"}, S3, "HTTP 409"]]) + assert r[0] == f"Start monitoring not confirmed: {sent['detail']}" + assert r[1] == f"Stop monitoring not confirmed: {sent['detail']}" + assert r[2] == f"Start monitoring failed: the unit did not answer: no reply — {HINT}" + assert r[3] == "Stop monitoring failed: not BE9441: BE12599 answered" + assert not any(x.startswith(("Start monitoring failed", "Stop monitoring failed")) for x in r[:2]) + + +def test_serial_mode_hides_the_legacy_forms(): + # #6 / #12: by serial, settings are read-only until phase 5 -- no empty edit + # form, no empty legacy tables; the settings box shows from the start. + r = run(["serialPanes", [True, False]], ["serialPanes", [True, True]], ["serialPanes", [False, False]]) + assert r == [{"configForm": False, "settingsBox": True, "settingsPlaceholder": True, "legacyDeviceTables": False}, + {"configForm": False, "settingsBox": True, "settingsPlaceholder": False, "legacyDeviceTables": False}, + {"configForm": True, "settingsBox": False, "settingsPlaceholder": False, "legacyDeviceTables": True}]