diff --git a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md
index c72d3a1..8d2a104 100644
--- a/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md
+++ b/docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md
@@ -681,7 +681,9 @@ a short plan; #14 waits for the line-hold decision above.
4. List vector sum 0 / −0 for three events whose peaks reach 1.08 in/s --
suspected escapes in the `0C` record (not checked).
5. Stored S3 event: client "Terra-Mechanic" (last letter missing) -- unexplained.
-6. Page: the Config tab shows the empty write form until Read in serial mode.
+6. ✅ **Fixed 2026-11-02 (Batch 2):** by serial the edit form stays hidden and the settings
+ box shows from the start ("Not read yet"); another unit's settings are cleared.
+ Page: the Config tab shows the empty write form until Read in serial mode.
7. `/db/events` 500 "database is locked" on the first page load against a new DB.
8. ✅ **Fixed `9492e49`**, plus `3a1d34a` ("already stored" also matches the Blastware
name: a histogram's row sits a second off its 0C time). The download carries the assembled Blastware file and is
@@ -704,10 +706,14 @@ a short plan; #14 waits for the line-hold decision above.
**S3 start over a modem:** the line dropped during the sensor check, the
read-back hit `Broken pipe` and did not reconnect → 503 though the start
worked. Fix: reconnect for the read-back (reads only; the send stays single).
-10. Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording.
+10. ✅ **Fixed 2026-11-02 (Batch 2):** the start/stop route adds `sent` + `audit_id` to a
+ ChangeUnconfirmed (same status and message); the page says "… not confirmed:".
+ Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording.
11. S3 stop ~19 s, 11.6 s of it the identity check (a full connect) vs ~1 s for a
serial-only read. **Identified only** (speed is secondary to reliability).
-12. Page, serial mode: the Device tab's empty legacy compliance table; S4
+12. ✅ **Fixed 2026-11-02 (Batch 2):** by serial the legacy tables are hidden behind a
+ pointer to the Config tab; a Micromate's Firmware reads "Thor line (version not read)".
+ Page, serial mode: the Device tab's empty legacy compliance table; S4
Firmware "—" (should say Thor line).
13. S4 mic in the event's peaks "0.0 dBL" vs 96.54 dB(L) in the file -- the
`0x0C` mic denormal parked above, now visible.
@@ -717,7 +723,10 @@ a short plan; #14 waits for the line-hold decision above.
**RETRACTED 2026-10-29: not a bug.** `sent` is documented as 1 acknowledged, 0
nothing sent, NULL unknown (`sfm/database.py`, `change.py`); a frame answered by a
ring instead of its ack is exactly unknown, and the row's `error` says it was sent.
-16. Page: a 504 on a unit THOR holds should say "connected, but no reply --
+16. ✅ **Fixed 2026-11-02 (Batch 2):** a 504 with nothing sent adds "the connection opened,
+ so the modem is reachable — another program (THOR or Blastware) may be holding
+ this unit's line, or the unit is busy".
+ Page: a 504 on a unit THOR holds should say "connected, but no reply --
another program may be holding this unit's line".
17. ✅ **Range part fixed 2026-11-02:** a MiniMate downloaded *while monitoring*
answers 1A with its device-info block, so no range was read and the stored
diff --git a/sfm/server.py b/sfm/server.py
index 1ce3b37..c1b5ae3 100644
--- a/sfm/server.py
+++ b/sfm/server.py
@@ -86,7 +86,7 @@ from sfm import db_snapshot
from sfm.event_ingest import backfill_series3_event, persist_download
import dataclasses
from sfm.device_access import DeviceAccess, DeviceError, UnitAddress
-from sfm.device_access.errors import BadRequest
+from sfm.device_access.errors import BadRequest, ChangeUnconfirmed
from sfm.device_access.series import normalise_serial, series_for_serial
from sfm.audit import DbAudit
@@ -400,9 +400,20 @@ def _via_device_access(fn) -> dict:
def _change_response(fn) -> JSONResponse:
"""Run a start/stop; the ChangeResult is the body, its outcome picks the status.
- DeviceError mapping is _via_device_access's -- not repeated here.
+ DeviceError mapping is _via_device_access's -- not repeated here. A change
+ that went out, or may have (ChangeUnconfirmed), keeps that status and message
+ and adds `sent` ("acknowledged" / "unknown") and `audit_id`, so a client can
+ tell it from a failure that sent nothing without matching the wording
+ (bench finding #10, 2026-11-02).
"""
- body = _via_device_access(fn)
+ try:
+ body = _via_device_access(fn)
+ except HTTPException as exc:
+ cause = exc.__cause__
+ if not isinstance(cause, ChangeUnconfirmed):
+ raise
+ return JSONResponse(status_code=exc.status_code,
+ content={"detail": exc.detail, "sent": cause.sent, "audit_id": cause.audit_id})
# An allow-list: only a dry run, a skip, or a change read back as made is a 200.
ok = (body["outcome"] in ("dry_run", "skipped")
or (body["outcome"] == "sent" and body["verified"] == "ok"))
diff --git a/sfm/sfm_webapp.html b/sfm/sfm_webapp.html
index ab442e8..31e420c 100644
--- a/sfm/sfm_webapp.html
+++ b/sfm/sfm_webapp.html
@@ -952,11 +952,14 @@
- Compliance Config
-
+ Settings: Config tab → Read from Device
+
+
Compliance Config
+
-
Project Info
-
+
Project Info
+
+
diff --git a/sfm/static/device_routing.js b/sfm/static/device_routing.js
index ac1f0cd..512d066 100644
--- a/sfm/static/device_routing.js
+++ b/sfm/static/device_routing.js
@@ -154,4 +154,42 @@ function downloadSummary(body) {
if (body.inserted === false) return `already stored — ${body.stored_filename}`;
return `stored ${body.stored_filename}, ${body.filesize} bytes, check: ${(body.detail || {}).check}`;
}
+
+// A Micromate's version string lives in 0x01, undecoded; which firmware line it
+// runs comes free with every reply (bench finding #12).
+const FIRMWARE_LINES = { thor: 'Thor line (version not read)', blastware: 'Blastware line (version not read)' };
+function firmwareLabel(info) {
+ const i = info || {};
+ return i.firmware_version || i.firmware || FIRMWARE_LINES[(i.detail || {}).firmware_line] || '—';
+}
+
+// A failed device request's message. A 504 is a unit that took the connection
+// but never answered: while THOR polls a Micromate, SFM's connection is accepted
+// and gets 0 bytes (measured 2026-10-29, bench finding #16). The hint is left
+// off once a change was sent -- its own message says what happened.
+const NO_REPLY_HINT = 'the connection opened, so the modem is reachable — another program (THOR or '
+ + "Blastware) may be holding this unit's line, or the unit is busy (e.g. its sensor check)";
+function errorDetail(body, statusText) {
+ const b = body || {}, d = b.detail;
+ return b.outcome ? changeSummary(b) : typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : statusText;
+}
+function deviceErrorText(status, body, unit, statusText) {
+ const text = errorDetail(body, statusText);
+ return status === 504 && !(body || {}).sent && unit && unit.host ? `${text} — ${NO_REPLY_HINT}` : text;
+}
+
+// A start/stop that went out (or may have) is not "failed": its body carries
+// `sent` (ChangeUnconfirmed, bench finding #10), and its message says what the
+// unit did and names the audit record.
+function changeErrorText(verb, status, body, unit, statusText) {
+ if ((body || {}).sent) return `${verb} monitoring not confirmed: ${errorDetail(body, statusText)}`;
+ return `${verb} monitoring failed: ${deviceErrorText(status, body, unit, statusText)}`;
+}
+
+// By serial, settings are read-only until phase 5: no empty legacy edit form or
+// legacy tables, and the settings box shows from the start (#6, #12).
+function serialPanes(bySerial, settingsRead) {
+ return { configForm: !bySerial, settingsBox: bySerial, settingsPlaceholder: bySerial && !settingsRead,
+ legacyDeviceTables: !bySerial };
+}
/* */
diff --git a/sfm/static/sfm_webapp.js b/sfm/static/sfm_webapp.js
index 91ee01d..0697cdd 100644
--- a/sfm/static/sfm_webapp.js
+++ b/sfm/static/sfm_webapp.js
@@ -73,9 +73,7 @@ async function deviceFetch(action, params = {}, opts = {}) {
const r = await deviceRequest(action, params, opts);
const body = await r.json().catch(() => ({}));
if (!r.ok) {
- const d = body.detail;
- const err = new Error(body.outcome ? changeSummary(body)
- : typeof d === 'string' ? d : d ? (d.message || JSON.stringify(d)) : r.statusText);
+ const err = new Error(deviceErrorText(r.status, body, currentUnit(), r.statusText));
err.status = r.status; err.body = body;
throw err;
}
@@ -102,6 +100,22 @@ function applyControls() {
chr.title = s4;
document.getElementById('ch-series-note').textContent = s4;
setMonitorButtons();
+ applyConfigPanes();
+}
+
+// The Config tab by serial (#6): settings are read-only until phase 5, so the
+// empty legacy edit form stays hidden and the settings box shows from the start.
+// A different unit's settings are never left on screen.
+let settingsShownFor = null;
+function applyConfigPanes() {
+ const serial = normSerial(currentUnit().serial);
+ const p = serialPanes(Boolean(serial), Boolean(serial) && settingsShownFor === serial);
+ document.getElementById('cfg-form').style.display = p.configForm ? '' : 'none';
+ document.getElementById('cfg-settings').style.display = p.settingsBox ? 'block' : 'none';
+ if (p.settingsPlaceholder) {
+ settingsShownFor = null;
+ renderTextTable('cfg-settings-table', [['Settings', 'Not read yet — press Read from Device']]);
+ }
}
async function hangUp() {
@@ -430,8 +444,7 @@ async function changeMonitoring(action) {
if (body.outcome) {
setStatus(changeSummary(body), r.ok ? 'ok' : 'error');
} else {
- const d = body.detail;
- setStatus(`${verb} monitoring failed: ${typeof d === 'string' ? d : d ? JSON.stringify(d) : r.statusText}`, 'error');
+ setStatus(changeErrorText(verb, r.status, body, currentUnit(), r.statusText), 'error');
}
} catch (e) {
// No reply is not "nothing sent": the request may have reached the unit.
@@ -454,7 +467,7 @@ function populateDeviceTab() {
const cardData = [
{ label:'Serial Number', value: unitInfo.serial || '—' },
{ label:'Series', value: confirmedSeries(currentUnit()) ?? '—' },
- { label:'Firmware', value: unitInfo.firmware_version || unitInfo.firmware || '—' },
+ { label:'Firmware', value: firmwareLabel(unitInfo) },
{ label:'DSP', value: unitInfo.dsp_version || (unitInfo.detail || {}).dsp_version || '—' },
{ label:'Model', value: unitInfo.model || '—' },
{ label:'Manufacturer', value: unitInfo.manufacturer || (unitInfo.detail || {}).manufacturer || '—' },
@@ -471,6 +484,11 @@ function populateDeviceTab() {
cards.appendChild(c);
}
+ // The legacy settings tables are empty by serial (#12); the Config tab reads them.
+ const legacy = serialPanes(serialMode(), false).legacyDeviceTables;
+ document.getElementById('dev-legacy-tables').hidden = !legacy;
+ document.getElementById('dev-serial-note').hidden = legacy;
+
// Compliance table
const cc = unitInfo.compliance_config || {};
const RECORDING_MODE_LABELS = {0: 'Single Shot', 1: 'Continuous', 3: 'Histogram', 4: 'Histogram + Continuous'};
@@ -713,6 +731,7 @@ async function readSettingsBySerial() {
try {
const st = await deviceFetch('settings');
renderTextTable('cfg-settings-table', settingsRows(st));
+ settingsShownFor = normSerial(st.serial);
document.getElementById('cfg-settings').style.display = 'block';
document.getElementById('cfg-form').style.display = 'none';
setCfgStatus(`Settings read from ${st.serial}.`, 'ok');
diff --git a/tests/test_server_device_access.py b/tests/test_server_device_access.py
index 93bd2f3..08aaedb 100644
--- a/tests/test_server_device_access.py
+++ b/tests/test_server_device_access.py
@@ -2,6 +2,8 @@
FastAPI Query() defaults are FieldInfo objects, not values."""
from __future__ import annotations
+import json
+
import os
import sys
@@ -418,10 +420,13 @@ def test_a_change_unconfirmed_keeps_its_cause_status_and_names_the_audit_record(
"failed: silent -- audit record c7", audit_id="c7", sent="acknowledged",
http_status=504)
monkeypatch.setattr(srv, "_device_access_instance", Raises())
- with pytest.raises(HTTPException) as e:
- srv.device_monitor_start(**CH)
- assert e.value.status_code == 504
- assert "audit record c7" in e.value.detail
+ resp = srv.device_monitor_start(**CH)
+ assert resp.status_code == 504 # the cause's status, unchanged
+ body = json.loads(resp.body)
+ assert "audit record c7" in body["detail"]
+ # #10 (2026-11-02): the page tells "may have been sent" from "nothing sent" by
+ # these, not by matching the message.
+ assert (body["sent"], body["audit_id"]) == ("acknowledged", "c7")
def test_device_commands_normalises_the_serial(tmp_path, monkeypatch):
diff --git a/tests/test_webapp_device_routing.py b/tests/test_webapp_device_routing.py
index 2110ea4..9686eba 100644
--- a/tests/test_webapp_device_routing.py
+++ b/tests/test_webapp_device_routing.py
@@ -28,7 +28,7 @@ NODE = shutil.which("node")
pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the page-logic tests need it")
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows", "perIndexLive", "escapeHtml",
- "changeSummary", "downloadSummary"]
+ "changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes"]
def _block() -> str:
@@ -234,3 +234,59 @@ def test_the_per_index_routes_follow_the_list_not_the_keyboard():
def test_escape_html_makes_a_unit_string_inert():
r = run(["escapeHtml", ['Bench &\'']], ["escapeHtml", [None]], ["escapeHtml", [42]])
assert r == ["Bench <b id="x">&'", "", "42"]
+
+
+
+# ── Batch 2 (1c bench polish, 2026-11-02) ─────────────────────────────────────
+
+def test_firmware_label_says_which_line_a_micromate_runs():
+ # #12: a Micromate's version string is in 0x01, undecoded; its firmware line is known.
+ r = run(["firmwareLabel", [{"firmware": "S338.17"}]], ["firmwareLabel", [{"firmware_version": "S338.17"}]],
+ ["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "thor"}}]],
+ ["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "blastware"}}]],
+ ["firmwareLabel", [{"firmware": None, "detail": {"firmware_line": "unknown"}}]],
+ ["firmwareLabel", [{}]], ["firmwareLabel", [None]])
+ assert r == ["S338.17", "S338.17", "Thor line (version not read)", "Blastware line (version not read)",
+ "—", "—", "—"]
+
+
+HINT = ("the connection opened, so the modem is reachable — another program (THOR or Blastware) may be "
+ "holding this unit's line, or the unit is busy (e.g. its sensor check)")
+
+
+def test_a_504_says_another_program_may_hold_the_line():
+ # #16: measured 2026-10-29 -- while THOR polls a Micromate, SFM's connection is
+ # accepted and gets 0 bytes, a 504. The hint is not added once a change was sent.
+ silent = {"detail": "the unit did not answer: no reply"}
+ sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x "
+ "-- audit record c7", "sent": "acknowledged", "audit_id": "c7"}
+ r = run(["deviceErrorText", [504, silent, S4, "HTTP 504"]], ["deviceErrorText", [504, sent, S4, "HTTP 504"]],
+ ["deviceErrorText", [503, {"detail": "could not connect: refused"}, S4, "HTTP 503"]],
+ ["deviceErrorText", [504, silent, {"serial": "UM20147", "host": "", "tcpPort": 9034}, "HTTP 504"]],
+ ["deviceErrorText", [502, {}, S4, "HTTP 502"]])
+ assert r == [f"the unit did not answer: no reply — {HINT}", sent["detail"], "could not connect: refused",
+ "the unit did not answer: no reply", "HTTP 502"]
+
+
+def test_a_change_that_was_sent_is_not_called_failed():
+ # #10: a ChangeUnconfirmed body carries `sent`; anything else is a real failure.
+ sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x "
+ "-- audit record c7", "sent": "acknowledged", "audit_id": "c7"}
+ r = run(["changeErrorText", ["Start", 504, sent, S3, "HTTP 504"]],
+ ["changeErrorText", ["Stop", 503, {**sent, "sent": "unknown"}, S3, "HTTP 503"]],
+ ["changeErrorText", ["Start", 504, {"detail": "the unit did not answer: no reply"}, S3, "HTTP 504"]],
+ ["changeErrorText", ["Stop", 409, {"detail": "not BE9441: BE12599 answered"}, S3, "HTTP 409"]])
+ assert r[0] == f"Start monitoring not confirmed: {sent['detail']}"
+ assert r[1] == f"Stop monitoring not confirmed: {sent['detail']}"
+ assert r[2] == f"Start monitoring failed: the unit did not answer: no reply — {HINT}"
+ assert r[3] == "Stop monitoring failed: not BE9441: BE12599 answered"
+ assert not any(x.startswith(("Start monitoring failed", "Stop monitoring failed")) for x in r[:2])
+
+
+def test_serial_mode_hides_the_legacy_forms():
+ # #6 / #12: by serial, settings are read-only until phase 5 -- no empty edit
+ # form, no empty legacy tables; the settings box shows from the start.
+ r = run(["serialPanes", [True, False]], ["serialPanes", [True, True]], ["serialPanes", [False, False]])
+ assert r == [{"configForm": False, "settingsBox": True, "settingsPlaceholder": True, "legacyDeviceTables": False},
+ {"configForm": False, "settingsBox": True, "settingsPlaceholder": False, "legacyDeviceTables": False},
+ {"configForm": True, "settingsBox": False, "settingsPlaceholder": False, "legacyDeviceTables": True}]