diff --git a/sfm/sfm_webapp.html b/sfm/sfm_webapp.html
index 31e420c..6a49f14 100644
--- a/sfm/sfm_webapp.html
+++ b/sfm/sfm_webapp.html
@@ -1141,6 +1141,16 @@
═══════════════════════════════════════════════════════════════════ -->
+
+
On the unit (by serial)
+
+
+
+
+
+
+
+
+
-
+
diff --git a/sfm/static/device_routing.js b/sfm/static/device_routing.js
index 512d066..e2f44a0 100644
--- a/sfm/static/device_routing.js
+++ b/sfm/static/device_routing.js
@@ -44,6 +44,9 @@ const DEVICE_ROUTES = {
slow_drip: ['POST', '/device/stop_monitoring_slow_drip', false],
call_home_read: ['GET', '/device/call_home', false],
call_home_write: ['POST', '/device/call_home', false],
+ call_home_state: ['GET', '/device/call_home/state', true],
+ call_home_on: ['POST', '/device/call_home/enable', true],
+ call_home_off: ['POST', '/device/call_home/disable', true],
config_write: ['POST', '/device/config', false],
event_waveform: ['GET', '/device/event/{index}/waveform', false],
event_file: ['GET', '/device/event/{index}/blastware_file', false],
@@ -82,10 +85,13 @@ function controlsFor(unit) {
startStop: serialMode && (series === 3 || series === 4),
hangup: series === 4,
diagnostics: series === 3,
- callHomeRead: series === 3,
+ // by host, the legacy read is Series 3's; by serial, both series (phase 4)
+ callHomeRead: series === 3 || (serialMode && series === 4),
+ callHomeChange: serialMode && (series === 3 || series === 4),
configWrite: false,
callHomeWrite: false,
- reasons: { configWrite: 'Coming in phase 5 (#46)', callHomeWrite: 'Coming in phase 4' },
+ reasons: { configWrite: 'Coming in phase 5 (#46)',
+ callHomeWrite: 'By serial: use Call-home On / Off (audited). Other call-home fields wait for the THOR round.' },
};
}
@@ -178,18 +184,28 @@ function deviceErrorText(status, body, unit, statusText) {
return status === 504 && !(body || {}).sent && unit && unit.host ? `${text} — ${NO_REPLY_HINT}` : text;
}
-// A start/stop that went out (or may have) is not "failed": its body carries
-// `sent` (ChangeUnconfirmed, bench finding #10), and its message says what the
-// unit did and names the audit record.
-function changeErrorText(verb, status, body, unit, statusText) {
- if ((body || {}).sent) return `${verb} monitoring not confirmed: ${errorDetail(body, statusText)}`;
- return `${verb} monitoring failed: ${deviceErrorText(status, body, unit, statusText)}`;
+// A change that went out (or may have) is not "failed": its body carries `sent`
+// (ChangeUnconfirmed, bench finding #10), and its message says what the unit
+// did and names the audit record. `label` is the whole name: "Start monitoring",
+// "Enable call-home".
+function changeErrorText(label, status, body, unit, statusText) {
+ if ((body || {}).sent) return `${label} not confirmed: ${errorDetail(body, statusText)}`;
+ return `${label} failed: ${deviceErrorText(status, body, unit, statusText)}`;
}
// By serial, settings are read-only until phase 5: no empty legacy edit form or
// legacy tables, and the settings box shows from the start (#6, #12).
function serialPanes(bySerial, settingsRead) {
return { configForm: !bySerial, settingsBox: bySerial, settingsPlaceholder: bySerial && !settingsRead,
- legacyDeviceTables: !bySerial };
+ legacyDeviceTables: !bySerial, callHomeForm: !bySerial, callHomeBox: bySerial };
+}
+
+// A unit's call-home switch, read by serial (phase 4). `enabled` null is an
+// enable byte never measured -- shown with the byte, never as On or Off.
+function callHomeRows(state) {
+ const s = state || {};
+ const sw = s.enabled === true ? 'On' : s.enabled === false ? 'Off'
+ : `Unknown (byte 5 = ${(s.detail || {}).byte5 ?? '?'})`;
+ return [['Call-home', sw], ['Dial string', s.dial_string || '—'], ['Series', s.series]];
}
/* */
diff --git a/sfm/static/sfm_webapp.js b/sfm/static/sfm_webapp.js
index 0697cdd..1a707d4 100644
--- a/sfm/static/sfm_webapp.js
+++ b/sfm/static/sfm_webapp.js
@@ -96,11 +96,71 @@ function applyControls() {
hw.disabled = !c.callHomeWrite; hw.title = c.reasons.callHomeWrite;
const chr = document.getElementById('ch-read-btn');
chr.disabled = !c.callHomeRead;
- const s4 = series === 4 ? 'Not yet available for Series 4' : '';
+ const s4 = series === 4 && !c.callHomeRead ? "Series 4: type the unit's serial to read its call-home" : '';
chr.title = s4;
document.getElementById('ch-series-note').textContent = s4;
+ for (const id of ['ch-on-btn', 'ch-off-btn']) {
+ document.getElementById(id).disabled = !c.callHomeChange || changeInFlight;
+ }
setMonitorButtons();
applyConfigPanes();
+ applyCallHomePanes();
+}
+
+// The Call Home tab by serial (phase 4): the unit's switch and audited On / Off;
+// the legacy multi-field form is Series 3 by host only.
+let callHomeShownFor = null;
+function applyCallHomePanes() {
+ const serial = normSerial(currentUnit().serial);
+ const p = serialPanes(Boolean(serial), false);
+ document.getElementById('ch-legacy').style.display = p.callHomeForm ? '' : 'none';
+ document.getElementById('ch-serial').style.display = p.callHomeBox ? 'block' : 'none';
+ document.getElementById('ch-write-btn').hidden = !p.callHomeForm;
+ document.getElementById('ch-clear-btn').hidden = !p.callHomeForm;
+ if (p.callHomeBox && callHomeShownFor !== serial) {
+ callHomeShownFor = null;
+ renderTextTable('ch-state', [['Call-home', 'Not read yet — press Read from Device']]);
+ }
+}
+
+// `quiet`: the re-read after a change -- the change's own result stays on screen.
+async function readCallHomeBySerial({ quiet = false } = {}) {
+ const btn = document.getElementById('ch-read-btn');
+ btn.disabled = true;
+ if (!quiet) setChStatus('Reading call-home from the unit…');
+ try {
+ const st = await deviceFetch('call_home_state');
+ renderTextTable('ch-state', callHomeRows(st));
+ callHomeShownFor = normSerial(st.serial);
+ if (!quiet) setChStatus(`Call-home read from ${st.serial}.`, 'ok');
+ } catch (e) {
+ if (!quiet) setChStatus(`Read failed: ${e.message}`, 'error');
+ else renderTextTable('ch-state', [['Call-home', `Re-read failed: ${e.message}`]]);
+ } finally {
+ btn.disabled = false;
+ }
+}
+
+// One audited send, never retried; the body says what the unit did.
+async function changeCallHome(on) {
+ const serial = normSerial(currentUnit().serial);
+ const label = on ? 'Enable call-home' : 'Disable call-home';
+ if (!confirm(`Turn call-home ${on ? 'ON' : 'OFF'} on ${serial}?`)) return;
+ changeInFlight = true; applyControls();
+ setChStatus(`${label}…`);
+ try {
+ const r = await deviceRequest(on ? 'call_home_on' : 'call_home_off');
+ const body = await r.json().catch(() => ({}));
+ setChStatus(body.outcome ? changeSummary(body)
+ : changeErrorText(label, r.status, body, currentUnit(), r.statusText),
+ r.ok ? 'ok' : 'error');
+ } catch (e) {
+ // No reply is not "nothing sent": the request may have reached the unit.
+ setChStatus(`${label}: no reply from SFM (${e.message}) — it may have been sent; `
+ + `check the unit's state and GET /db/device_commands`, 'error');
+ }
+ changeInFlight = false; applyControls();
+ await readCallHomeBySerial({ quiet: true });
}
// The Config tab by serial (#6): settings are read-only until phase 5, so the
@@ -444,7 +504,7 @@ async function changeMonitoring(action) {
if (body.outcome) {
setStatus(changeSummary(body), r.ok ? 'ok' : 'error');
} else {
- setStatus(changeErrorText(verb, r.status, body, currentUnit(), r.statusText), 'error');
+ setStatus(changeErrorText(`${verb} monitoring`, r.status, body, currentUnit(), r.statusText), 'error');
}
} catch (e) {
// No reply is not "nothing sent": the request may have reached the unit.
@@ -862,6 +922,7 @@ function clearCallHomeForm() {
async function readCallHome() {
if (!devHost()) { setChStatus('Not connected.', 'error'); return; }
+ if (serialMode()) { await readCallHomeBySerial(); return; }
setChStatus('Reading call home config from device…');
document.getElementById('ch-read-btn').disabled = true;
try {
@@ -2275,6 +2336,9 @@ document.getElementById('api-base').value = window.location.origin;
for (const id of ['dev-serial', 'dev-host', 'dev-port']) {
document.getElementById(id).addEventListener('input', () => { unitConfirmed = null; applyControls(); });
}
+// New controls are wired here, not with onclick= in the HTML (no inline JS).
+document.getElementById('ch-on-btn').addEventListener('click', () => changeCallHome(true));
+document.getElementById('ch-off-btn').addEventListener('click', () => changeCallHome(false));
applyControls();
// Reflect any persisted mic-unit preference in the header pill on load
diff --git a/tests/test_webapp_device_routing.py b/tests/test_webapp_device_routing.py
index 9686eba..37e3578 100644
--- a/tests/test_webapp_device_routing.py
+++ b/tests/test_webapp_device_routing.py
@@ -28,7 +28,8 @@ NODE = shutil.which("node")
pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the page-logic tests need it")
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows", "perIndexLive", "escapeHtml",
- "changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes"]
+ "changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes",
+ "callHomeRows"]
def _block() -> str:
@@ -108,7 +109,8 @@ def test_controls_confirmed_series3():
def test_controls_confirmed_series4():
c = run(["controlsFor", [_with(S4, {"serial": "UM20147", "series": 4})]])[0]
- assert (c["hangup"], c["startStop"], c["diagnostics"], c["callHomeRead"]) == (True, True, False, False)
+ # phase 4: by serial a Micromate's call-home reads through /device/call_home/state
+ assert (c["hangup"], c["startStop"], c["diagnostics"], c["callHomeRead"]) == (True, True, False, True)
def test_controls_confirmation_drops_when_the_serial_changes():
@@ -124,11 +126,13 @@ def test_controls_a_legacy_identify_confirms_without_a_typed_serial():
assert s == 3 and c["diagnostics"] is True and c["startStop"] is False # start/stop needs a serial
-def test_controls_writes_wait_for_phases_4_and_5():
+def test_controls_config_waits_for_phase_5_and_the_legacy_call_home_form_stays_off():
for unit in (_with(S3, {"serial": "BE9441", "series": 3}), _with(S4, {"serial": "UM20147", "series": 4})):
c = run(["controlsFor", [unit]])[0]
assert c["configWrite"] is False and c["callHomeWrite"] is False
- assert c["reasons"] == {"configWrite": "Coming in phase 5 (#46)", "callHomeWrite": "Coming in phase 4"}
+ assert c["reasons"] == {"configWrite": "Coming in phase 5 (#46)",
+ "callHomeWrite": "By serial: use Call-home On / Off (audited). Other call-home "
+ "fields wait for the THOR round."}
def test_change_summary():
@@ -272,10 +276,12 @@ def test_a_change_that_was_sent_is_not_called_failed():
# #10: a ChangeUnconfirmed body carries `sent`; anything else is a real failure.
sent = {"detail": "start monitoring was sent and acknowledged, but reading the state back failed: x "
"-- audit record c7", "sent": "acknowledged", "audit_id": "c7"}
- r = run(["changeErrorText", ["Start", 504, sent, S3, "HTTP 504"]],
- ["changeErrorText", ["Stop", 503, {**sent, "sent": "unknown"}, S3, "HTTP 503"]],
- ["changeErrorText", ["Start", 504, {"detail": "the unit did not answer: no reply"}, S3, "HTTP 504"]],
- ["changeErrorText", ["Stop", 409, {"detail": "not BE9441: BE12599 answered"}, S3, "HTTP 409"]])
+ r = run(["changeErrorText", ["Start monitoring", 504, sent, S3, "HTTP 504"]],
+ ["changeErrorText", ["Stop monitoring", 503, {**sent, "sent": "unknown"}, S3, "HTTP 503"]],
+ ["changeErrorText", ["Start monitoring", 504, {"detail": "the unit did not answer: no reply"}, S3,
+ "HTTP 504"]],
+ ["changeErrorText", ["Stop monitoring", 409, {"detail": "not BE9441: BE12599 answered"}, S3,
+ "HTTP 409"]])
assert r[0] == f"Start monitoring not confirmed: {sent['detail']}"
assert r[1] == f"Stop monitoring not confirmed: {sent['detail']}"
assert r[2] == f"Start monitoring failed: the unit did not answer: no reply — {HINT}"
@@ -287,6 +293,37 @@ def test_serial_mode_hides_the_legacy_forms():
# #6 / #12: by serial, settings are read-only until phase 5 -- no empty edit
# form, no empty legacy tables; the settings box shows from the start.
r = run(["serialPanes", [True, False]], ["serialPanes", [True, True]], ["serialPanes", [False, False]])
- assert r == [{"configForm": False, "settingsBox": True, "settingsPlaceholder": True, "legacyDeviceTables": False},
- {"configForm": False, "settingsBox": True, "settingsPlaceholder": False, "legacyDeviceTables": False},
- {"configForm": True, "settingsBox": False, "settingsPlaceholder": False, "legacyDeviceTables": True}]
+ serial = {"configForm": False, "settingsBox": True, "legacyDeviceTables": False,
+ "callHomeForm": False, "callHomeBox": True}
+ legacy = {"configForm": True, "settingsBox": False, "settingsPlaceholder": False, "legacyDeviceTables": True,
+ "callHomeForm": True, "callHomeBox": False}
+ assert r == [{**serial, "settingsPlaceholder": True}, {**serial, "settingsPlaceholder": False}, legacy]
+
+
+
+# ── Call home by serial (phase 4) ─────────────────────────────────────────────
+
+def test_call_home_routes_need_a_serial():
+ r = run(["deviceUrl", ["call_home_on", BLANK]], ["deviceUrl", ["call_home_on", S4]],
+ ["deviceUrl", ["call_home_off", S3]], ["deviceUrl", ["call_home_state", S4]])
+ assert r[0] is None
+ assert r[1] == {"method": "POST", "path": "/device/call_home/enable?serial=UM20147&host=h&tcp_port=9034"}
+ assert r[2] == {"method": "POST", "path": "/device/call_home/disable?serial=BE9441&host=h&tcp_port=9034"}
+ assert r[3] == {"method": "GET", "path": "/device/call_home/state?serial=UM20147&host=h&tcp_port=9034"}
+
+
+def test_call_home_change_needs_a_confirmed_series():
+ r = run(["controlsFor", [S3]], ["controlsFor", [_with(S3, {"serial": "BE9441", "series": 3})]],
+ ["controlsFor", [_with(S4, {"serial": "UM20147", "series": 4})]],
+ ["controlsFor", [_with(BLANK, {"serial": "BE9441", "series": 3})]])
+ assert [c["callHomeChange"] for c in r] == [False, True, True, False]
+
+
+def test_call_home_rows():
+ r = run(["callHomeRows", [{"enabled": True, "dial_string": "RADIO RING", "series": 4}]],
+ ["callHomeRows", [{"enabled": False, "dial_string": None, "series": 3}]],
+ ["callHomeRows", [{"enabled": None, "dial_string": "RADIO RING", "series": 3,
+ "detail": {"byte5": "0x07"}}]])
+ assert r[0] == [["Call-home", "On"], ["Dial string", "RADIO RING"], ["Series", 4]]
+ assert r[1] == [["Call-home", "Off"], ["Dial string", "—"], ["Series", 3]]
+ assert r[2][0] == ["Call-home", "Unknown (byte 5 = 0x07)"]