diff --git a/.gitignore b/.gitignore index 90e5d24..d6d14bf 100644 --- a/.gitignore +++ b/.gitignore @@ -1,33 +1,40 @@ -/bridges/captures/ -/example-events/ -/tests/fixtures/ -/manuals/ - -# Python build artifacts -*.egg-info/ -dist/ -build/ - -# Python bytecode -__pycache__/ -*.py[cod] - -# Virtual environments -.venv/ -venv/ -env/ - -# Editor / OS -.vscode/ -*.swp -.DS_Store -Thumbs.db - -# Analyzer outputs -*.report -claude_export_*.md - -# Frame database -*.db -*.db-wal -*.db-shm +/bridges/captures/ + +# Capture artefacts that land beside the bridge scripts. Deliberately NOT +# `/bridges/s3-bridge/` -- proxy.py and s3_bridge.py live there and are tracked. +/bridges/*.bin +/bridges/s3-bridge/*.bin +/bridges/s3-bridge/*.log +/bridges/s3-bridge/*.set +/example-events/ +/tests/fixtures/ +/manuals/ + +# Python build artifacts +*.egg-info/ +dist/ +build/ + +# Python bytecode +__pycache__/ +*.py[cod] + +# Virtual environments +.venv/ +venv/ +env/ + +# Editor / OS +.vscode/ +*.swp +.DS_Store +Thumbs.db + +# Analyzer outputs +*.report +claude_export_*.md + +# Frame database +*.db +*.db-wal +*.db-shm diff --git a/CLAUDE.md b/CLAUDE.md index cc80b6f..aa371fc 100644 --- a/CLAUDE.md +++ b/CLAUDE.md @@ -10,7 +10,7 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as --- -## Where things stand (updated 2026-09-26) +## Where things stand (updated 2026-10-14) Read this first when picking the project back up. @@ -22,14 +22,39 @@ Read this first when picking the project back up. firmware) or `0x03` (Thor firmware) rather than `0x10`, and the data length is a **uint16 BE at `payload[8:10]`** (as a byte it under-reads `SUB 0x1A` by 47x). Read path, event chain, setups, scheduler, monitoring control and - per-event delete are all mapped; **the inbound call-home session is the only - protocol unknown left.** + per-event delete are all mapped — **and as of 2026-10-14 so is the inbound + call-home session.** There are no protocol unknowns left. ⚠ **No command has ever been originated against a unit by this project.** Every write was performed by THOR while we recorded. That line is worth keeping. - ⚠ `micromate/` still has **no live client** — it is codec-only. The - `minimateplus/` stack (transport/framing/protocol/client) has no Series-4 - counterpart yet. `minimateplus.transport` is protocol-agnostic and reusable. +- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`, + `protocol.py`, `client.py` + models, **119 tests**, mirroring the + `minimateplus/` stack and reusing its `transport.py` unchanged. Connect over + TCP or serial, identify a unit, read state/clock/battery/memory, list setups, + walk the event chain and download + decode events. **Read-only** — every + write remains mapped-but-unimplemented, deliberately. + Verified on hardware across **both firmware lines** (UM12947 `11.0CB`, + UM20147 `11.0BD`) and **both transports** (USB CDC-ACM and an RX55 over + cellular), byte-identical. + ⚠ **The gap is config decoding**, not the protocol: `0x1A` (2,103 B) has + about a dozen fields read; `0x2C`, `0x2E`, `0x08`, `0x01` are fetched and + undecoded. Finishing it needs a bench session varying one setting at a time, + as was done for Series III — not desk work. +- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals + `RADIO RING`; **two paths exist and timing decides which**: if anything + already holds the modem's single TCP session the ring rides that connection, + otherwise the modem dials out to a listener. THOR's `UnitWatchDogTimer` + reconnects continuously, so THOR usually holds that slot — which is why + probes and relays see silence. That is contention, not a fault. + ⚠⚠ **`SUB 0xA2` ends a call-home on Series IV and is CONFIRM ERASE on + Series III** — same opcode, same `0x5D` response, opposite consequence. + `minimateplus` and `micromate` share a transport; dispatch on series before + that byte reaches a wire. + ⚠ **"Monitor While Calling Home" silently blocks erase**, and THOR reports + the session successful anyway. A receiver therefore **cannot rely on erase to + manage storage** — the server-side high-water mark is load-bearing. + ⚠ `bridges/mm_ach_server.py` implements the listener path only; it needs to + also hold outbound connections and watch for the ring. - **Bench tooling for device diagnosis (2026-09-25).** `bridges/mm_probe.py` distinguishes the four faults THOR reports identically as "disconnected" (refused / connect timeout / **connected but no reply** / replied) and names diff --git a/bridges/mm_ach_server.py b/bridges/mm_ach_server.py new file mode 100644 index 0000000..fbeb691 --- /dev/null +++ b/bridges/mm_ach_server.py @@ -0,0 +1,398 @@ +#!/usr/bin/env python3 +""" +mm_ach_server.py — inbound Auto Call Home server for Micromate (Series IV). + +**Read-only.** It identifies the unit, reads its state and setups, and walks the +event chain. It does not erase, does not write, does not start or stop +monitoring, and downloads nothing unless asked. Series III's `ach_server.py` +has "rescue actions" that quiet a runaway unit; those are deliberately absent +here, because no command has ever been originated against a unit by this project +and an inbound session is the worst place to break that. + +What this is for +---------------- +The inbound call-home session is the last unmapped part of the Series IV +protocol. + +⚠ **No Micromate has ever been observed calling home.** The 72 `ach_inbound_*` +sessions in `bridges/captures/` are **MiniMate Plus**, and the Series III setup +does not automatically transfer. What we have for Series IV is prior, not +observation: + + * The THOR manual §6.2 and the firmware's own strings + (`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`, `Call Home Deleting + Events`) say the unit dials in and then **waits to be told what to do** — + server-driven, the same shape as Series III's pull model. + * UM12947's `0x2C` dial string reads literally `"RADIO RING"`, which is modem + *answer* vocabulary rather than a destination. With the RV50 debug string + `ATQ1 ATE0 ATS0=2 … RADIO RING` — `ATS0=2` being auto-answer-after-2-rings — + that reads as the unit configuring the modem to **accept** calls, i.e. the + call-*up* path. Which suggests the ACH destination lives in the **modem**, + as it does for Series III. + +**If both priors hold, this file is just `MicromateClient` on an inbound socket +and the unknown evaporates.** But there is a specific way it can fail: + +⚠ **Those AT strings prove the Micromate talks to the modem over serial.** If it +drives an AT dial for call-home, that exchange happens on the **serial link**, +where a TCP listener sees nothing whatsoever. So a null result here is +informative but ambiguous — it means *either* the trigger did not fire *or* the +interesting part is happening somewhere this tool cannot watch. **If nothing +arrives, the next step is a serial-level capture between the unit and the modem, +not more fiddling with this server.** + +**The one question that matters is push vs pull**, and it cannot be answered by +sniffing — only by connecting and keeping quiet. So this server **says nothing +for `--grace` seconds** after accepting. If bytes arrive in that window the unit +speaks first (push) and the server reports exactly what it sent. If the window +passes in silence, it is pull, and the normal handshake follows. + +Setup +----- +1. Run this where the unit can reach it: + + python3 bridges/mm_ach_server.py --port 12345 + +2. Point the call-home destination at this machine. **For Series III that + lived in the MODEM's config (ACEmanager), not in the seismograph** — so try + AirLink OS first. If the RX55 can be told to open an outbound TCP session + to `:12345` on serial activity, nothing on the instrument needs to + change, which is much the better outcome. + + If it has to come from the unit instead, its `SUB 0x2C` call-home block + holds a 40-byte dial string — but **writing that is THOR's job, not ours.** + +3. Trigger a call. A scheduled time is the controllable option: repeatable, + needs no monitoring and no thumping. An event-triggered call is the more + interesting session, because it shows how an event gets offered. + +4. Watch. Every frame is decoded as it arrives. + +⚠ Use a bench unit. Changing a call-home destination means a unit stops +reporting to THOR until it is changed back. + +Output per session, in the layout `scratch/mm_frame_parse.py` reads directly: + + bridges/captures/mm_ach_/ + raw_bw_.bin us → unit + raw_s3_.bin unit → us + session_.log + session.json what we learned, including push-vs-pull +""" + +from __future__ import annotations + +import argparse +import datetime +import json +import logging +import socket +import sys +import threading +import time +from pathlib import Path + +sys.path.insert(0, str(Path(__file__).resolve().parent.parent)) + +from micromate.client import MicromateClient # noqa: E402 +from micromate.framing import MicromateFrameParser # noqa: E402 +from micromate.protocol import ProtocolError # noqa: E402 +from minimateplus.transport import SocketTransport # noqa: E402 + +log = logging.getLogger("mm_ach") + +DEPTHS = ("identify", "state", "events", "download") + +# Strings the MODEM puts on the wire, which are not the unit talking. +# +# `CLAUDE.md` already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n +# over TCP to the caller even with Quiet Mode enabled". An RX55 on AirLink OS +# says `RADIO RING` instead, space-padded and newline-separated. Observed +# 2026-10-14 from UM12947's modem: four of them and **no CONNECT**. +# +# ⚠ The absence of CONNECT is the useful part. RING means the modem is ringing +# the serial device; CONNECT means something answered. Rings without a CONNECT, +# and no answer to POLL, means the TCP side is fine and the UNIT is not on the +# other end of the serial link. +_MODEM_CHATTER = (b"RADIO RING", b"RING", b"CONNECT", b"NO CARRIER", b"BUSY", + b"NO ANSWER", b"ERROR", b"OK") + + +class Session: + """One inbound call. Captures every byte; decides push vs pull first.""" + + def __init__(self, sock: socket.socket, peer: str, args) -> None: + self.sock, self.peer, self.args = sock, peer, args + self.ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S") + self.found: dict = {"peer": peer, "started": self.ts} + self._rx: list[bytes] = [] + self._tx: list[bytes] = [] + self._rx_fh = self._tx_fh = None + + # ── byte taps ───────────────────────────────────────────────────────────── + + def _tap(self, transport) -> None: + """Mirror every byte, buffered until we know this is a real unit.""" + orig_read, orig_write = transport.read, transport.write + + def read(n: int) -> bytes: + data = orig_read(n) + if data: + (self._rx_fh.write(data), self._rx_fh.flush()) if self._rx_fh \ + else self._rx.append(data) + return data + + def write(data: bytes) -> None: + orig_write(data) + if data: + (self._tx_fh.write(data), self._tx_fh.flush()) if self._tx_fh \ + else self._tx.append(data) + + transport.read, transport.write = read, write + + def _open_capture(self) -> Path: + """Create the session directory — only once we trust the peer. + + A port scanner should leave nothing on disk. + """ + d = Path(self.args.output) / f"mm_ach_{self.ts}" + d.mkdir(parents=True, exist_ok=True) + # Named raw_bw/raw_s3 so scratch/mm_frame_parse.py reads the pair as-is. + self._tx_fh = open(d / f"raw_bw_{self.ts}.bin", "wb") + self._rx_fh = open(d / f"raw_s3_{self.ts}.bin", "wb") + for c in self._tx: + self._tx_fh.write(c) + for c in self._rx: + self._rx_fh.write(c) + self._tx_fh.flush() + self._rx_fh.flush() + self._tx.clear() + self._rx.clear() + return d + + # ── the experiment ──────────────────────────────────────────────────────── + + def _listen_first(self, transport) -> bytes: + """Say nothing for `--grace` seconds — unless a RING arrives. + + Originally this just answered "does the unit speak first?". THOR's ACH + log (2026-10-14) made the question sharper: on seeing `RADIO RING` it + replies in **36 ms**, and with `ReadSerialNumber`, not `POLL`. + + We were doing neither — sitting silent for the full 8 s and then sending + POLL. The unit may well have given up long before we spoke. So the + grace window now **ends the moment a ring is seen**, and the caller + answers it the way THOR does. + """ + print(f" listening in silence for up to {self.args.grace:.1f} s " + f"(ends early on a RING)...") + deadline = time.monotonic() + self.args.grace + got = bytearray() + while time.monotonic() < deadline: + chunk = transport.read(4096) + if chunk: + got += chunk + if b"RING" in got: + print(f" RING seen after " + f"{self.args.grace - (deadline - time.monotonic()):.2f} s" + f" — answering immediately, as THOR does") + return bytes(got) + else: + time.sleep(0.02) + return bytes(got) + + def run(self) -> None: + print(f"\n=== inbound from {self.peer} at {self.ts} ===") + transport = SocketTransport(self.sock, peer=self.peer) + self._tap(transport) + + unsolicited = self._listen_first(transport) + self.found["push"] = bool(unsolicited) + self.found["unsolicited_bytes"] = len(unsolicited) + + if unsolicited: + print(f" ** PUSH ** — the unit sent {len(unsolicited)} B unprompted") + print(f" hex : {unsolicited[:64].hex(' ')}") + txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64]) + print(f" ascii : |{txt}|") + hits = [c.decode() for c in _MODEM_CHATTER if c in unsolicited] + if hits: + rings = unsolicited.count(b"RING") + print(f" *** MODEM CHATTER, not the unit: {hits} ***") + self.found["modem_chatter"] = hits + self.found["ring_count"] = rings + if rings and b"CONNECT" not in unsolicited: + print(f" *** {rings} RING(s) and NO CONNECT. ***") + print(" The modem is ringing the serial device and nothing") + print(" is answering. TCP is fine; the UNIT is not on the") + print(" other end of the serial link. Check, in order:") + print(" 1. is the unit cabled to the modem at all?") + print(" 2. cable chipset -- FTDI (0403) or CDC-ACM only,") + print(" never Prolific (067b)") + print(" 3. cold-boot the unit WITH the cable attached;") + print(" its USB-A host port only enumerates at power-on") + self.found["diagnosis"] = "rings without connect: unit not on serial" + + frames = MicromateFrameParser().feed(unsolicited) + if frames: + for f in frames: + print(f" frame : SUB=0x{f.sub:02x} " + f"(answers 0x{f.request_sub:02x}) {len(f.data)} B data, " + f"flags=0x{f.flags:02x}, chk " + f"{'ok' if f.checksum_valid else 'BAD'}") + self.found["unsolicited_subs"] = [f"0x{f.sub:02x}" for f in frames] + else: + print(" frame : none parsed — not a response frame. Could be") + print(" a banner (series III sends 'Operating System'") + print(" on cold boot) or a greeting we have not seen.") + else: + print(" ** PULL ** — silence. The unit is waiting to be driven,") + print(" same as series III. Running the normal handshake.") + + # From here on it is the ordinary client, which is the point. + mm = MicromateClient(transport, recv_timeout=self.args.timeout) + try: + if b"RING" in unsolicited: + # ⚠ Answer a ring the way THOR does: SERIAL first, not POLL. + # THOR's ACH log shows ReadSerialNumber 36 ms after detecting the + # ring -- it is identifying which unit rang before doing anything + # else. Our POLL-after-8-seconds may simply have been too late + # and the wrong question. + print(" answering the ring with SERIAL (THOR's first move)...") + serial = _cstring(_content(mm.protocol.read_serial())) + print(f" *** THE UNIT ANSWERED: {serial} ***") + self.found["answered_ring"] = True + self.found["ring_serial"] = serial + info = mm.connect() + except ProtocolError as e: + print(f" handshake FAILED: {type(e).__name__}: {e}") + if not unsolicited: + print(" Nothing unprompted AND no answer to POLL — so this is") + print(" neither push nor pull as we understand it. The raw") + print(" capture is the thing to look at; keep it.") + self._finish(self._open_capture()) + return + + d = self._open_capture() + print(f" {info}") + self.found["device"] = { + "serial": info.serial, "model": info.model, + "firmware_line": info.firmware_line, "monitoring": info.monitoring, + "active_setup": info.active_setup, + } + + try: + if DEPTHS.index(self.args.depth) >= DEPTHS.index("state"): + st = mm.get_state() + print(f" {st}") + self.found["state"] = { + "monitoring": st.monitoring, + "device_time": st.device_time.isoformat() if st.device_time else None, + "battery_volts": st.battery_volts, + "memory_free_bytes": st.memory_free_bytes, + } + self.found["setups"] = mm.list_setups() + print(f" {len(self.found['setups'])} setups") + + if DEPTHS.index(self.args.depth) >= DEPTHS.index("events"): + refs = mm.list_events() + print(f" {len(refs)} events") + self.found["events"] = [] + for r in refs: + print(f" {r}") + self.found["events"].append({ + "uid": r.uid, "key": r.key_hex, "size": r.size, + "type": r.record_type, "filename": r.filename, + "timestamp": r.timestamp.isoformat() if r.timestamp else None, + "pvs_ips": r.peak_vector_sum_ips, + }) + + if self.args.depth == "download": + # Bounded on purpose: an unknown session is a poor place to + # discover that a 70 KB pull takes 30 s and the unit hung up. + for r in refs[: self.args.max_events]: + blob = mm.download_event(r) + out = d / (r.filename or f"{r.key_hex}.bin") + out.write_bytes(blob) + print(f" saved {out.name} ({len(blob)} B)") + except ProtocolError as e: + print(f" session ended early: {type(e).__name__}: {e}") + self.found["error"] = f"{type(e).__name__}: {e}" + + self._finish(d) + + def _finish(self, d: Path) -> None: + for fh in (self._rx_fh, self._tx_fh): + if fh: + fh.close() + (d / "session.json").write_text(json.dumps(self.found, indent=2)) + try: + self.sock.close() + except OSError: + pass + print(f" saved {d}") + print(f" parse with: python3 scratch/mm_frame_parse.py {d}") + + +def main() -> int: + ap = argparse.ArgumentParser( + description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter + ) + ap.add_argument("--port", type=int, default=12345) + ap.add_argument("--bind", default="0.0.0.0") + ap.add_argument("--output", default="bridges/captures") + ap.add_argument("--timeout", type=float, default=30.0, + help="per-command receive timeout; generous, because an " + "inbound cellular session is the slow case") + ap.add_argument("--grace", type=float, default=5.0, + help="seconds to stay SILENT after accepting, to see whether " + "the unit speaks first. This is the experiment; do not " + "set it to 0 on a first run.") + ap.add_argument("--depth", choices=DEPTHS, default="events", + help="how far to take the session. 'events' walks the chain " + "without downloading (default); 'download' also fetches " + "events, which on cellular is ~0.21 s + bytes/2350 each") + ap.add_argument("--max-events", type=int, default=3, + help="with --depth download, how many to fetch") + ap.add_argument("--once", action="store_true", + help="exit after the first session instead of listening on") + a = ap.parse_args() + + # ⚠ Without this, stdout is block-buffered whenever it is not a terminal, + # so the live session commentary sits in a buffer and the log looks EMPTY + # while a call is happening. That cost a confusing few minutes on the first + # real call-in: the session was on disk but nothing was on screen. + try: + sys.stdout.reconfigure(line_buffering=True) + except AttributeError: # pragma: no cover - py<3.7 + pass + + logging.basicConfig(level=logging.INFO, + format="%(asctime)s %(levelname)-7s %(message)s") + + srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM) + srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1) + srv.bind((a.bind, a.port)) + srv.listen(5) + print(f"\nMicromate ACH server on {a.bind}:{a.port} (READ-ONLY)") + print(f" depth={a.depth} grace={a.grace}s timeout={a.timeout}s") + print(" waiting for a unit to call in. Ctrl-C to stop.\n") + + try: + while True: + sock, addr = srv.accept() + peer = f"{addr[0]}:{addr[1]}" + s = Session(sock, peer, a) + if a.once: + s.run() + return 0 + threading.Thread(target=s.run, daemon=False).start() + except KeyboardInterrupt: + print("\nstopped") + return 0 + finally: + srv.close() + + +if __name__ == "__main__": + raise SystemExit(main()) diff --git a/bridges/mm_client_check.py b/bridges/mm_client_check.py index 1471672..f1e973f 100644 --- a/bridges/mm_client_check.py +++ b/bridges/mm_client_check.py @@ -55,7 +55,7 @@ from pathlib import Path sys.path.insert(0, str(Path(__file__).resolve().parent.parent)) from micromate.client import MicromateClient, _content # noqa: E402 -from micromate.protocol import ProtocolError # noqa: E402 +from micromate.protocol import CHUNK_SIZE, ProtocolError # noqa: E402 from minimateplus.transport import TcpTransport # noqa: E402 @@ -380,7 +380,14 @@ def main() -> int: for ref in mm.iter_events(): if ref.key_hex not in want_keys: continue - n_chunks = -(-ref.size // 1024) + # ⚠ Use the size actually requested. This printed + # `size // 1024` -- THOR's chunk size -- while the + # download used the 16 KB default, so it reported 71 + # requests for a walk that made 5. A diagnostic that + # misreports what it did is worse than one that says + # nothing, and this one nearly had me reading a working + # 16 KB download as a broken 1 KB one. + n_chunks = -(-ref.size // CHUNK_SIZE) note = (" <- past 64 KB, carries into params[1]" if ref.size > 0x10000 else "") t1 = time.monotonic() @@ -396,8 +403,8 @@ def main() -> int: check = ("PVS %+.4f%%" % (100 * err) if err is not None else "PVS n/a (histogram)") print(f" {ref.key_hex} {ref.record_type:9} " - f"{ref.size:7} B {n_chunks:3} chunks {dt:5.1f} s " - f"{n:6} samples {check}{note}") + f"{ref.size:7} B {n_chunks:3} req @ {CHUNK_SIZE} B " + f"{dt:5.1f} s {n:6} samples {check}{note}") except ProtocolError as e: print(f"\n ABORTED {type(e).__name__}: {e}") diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 561daaa..348ebba 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -1662,6 +1662,28 @@ through a record-type discriminator (`0x2C` partial vs `0x46` full) *on its event walk*, so partial records and events share one chain. Here the monitor log has its own cursor and the event chain never sees it. +### USB identification — the Micromate's own ports + +| device | VID:PID | appears as | +|---|---|---| +| **Micromate `PC` port (USB-B)** | **`2504:0300`** — *Instantel Inc. MICROMATE COM PORT* | `/dev/ttyACM*`, CDC-ACM | +| Sabrent cable (works on the USB-A host port) | `0403:*` — FTDI | `/dev/ttyUSB*` | +| Benfei cable (does **not** work) | `067b:*` — Prolific PL2303 | `/dev/ttyUSB*` | + +⚠ **Address the unit by `/dev/serial/by-id/`, not `/dev/ttyACM`.** The number +shifts whenever any other CDC-ACM device is plugged in, and this has already cost +a debugging session — the tool was aimed at a TMI-Seismo MCU and timed out +looking like a dead unit. The stable name is +`usb-Instantel_Inc._MICROMATE_COM_PORT_V1.00-if00`. + +The `PC` port is a USB **device** port, so it is safe to plug and unplug freely. +The cold-boot requirement applies only to the USB-A **host** port, where the +modem cable goes. + +**Passing one through to a Proxmox guest** works and hot-plugs, no VM restart: +`qm set -usb0 host=2504:0300`. Bind by VID:PID rather than bus-port so it +survives a replug. + #### 🔑 Every response has an 11-byte prefix — and its length byte lies **Content starts at `data[11]`.** One rule, every command. @@ -2256,12 +2278,308 @@ A server that never issues the delete simply re-reads the same events forever. `ach_state.json` with `downloaded_keys` / `max_downloaded_key`, and erase as a separate deliberate step. No new mechanism is needed for Series IV. +> #### ⚠ But no Micromate has ever been observed calling home (noted 2026-10-03) +> +> The 72 `ach_inbound_*` sessions in `bridges/captures/` are **MiniMate Plus**. +> The Series III setup is not known to transfer, and there is a concrete reason +> it might not: +> +> | | Series III (observed, 72 sessions) | Series IV (inferred) | +> |---|---|---| +> | who dials | the **modem** (destination set in ACEmanager) | unknown | +> | the unit's role | passive on serial until the socket exists | sends AT strings to the modem | +> | session | pull — server runs the ordinary command set | pull, per manual §6.2 + firmware strings | +> +> ⚠ **The Micromate demonstrably talks AT to its modem** — +> `ATQ1 ATE0 ATS0=2 … RADIO RING` from the RV50 debug, and `"RADIO RING"` is what +> `0x2C`'s dial-string field actually contains on UM12947. `ATS0=2` is +> auto-answer-after-2-rings, so that exchange is the unit arranging to *accept* +> calls — the call-*up* path — which argues the ACH destination lives in the +> modem after all. +> +> **But if the unit instead drives an AT dial for call-home, that exchange is on +> the serial link and a TCP listener sees none of it.** So the first experiment +> has an ambiguous null: no connection could mean the trigger did not fire, or +> that the interesting part is invisible from the network. The escalation is a +> **serial-level capture between unit and modem**, not more work on the server. + So a homebrew receiver needs: accept the connection, identify the unit, walk the events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water mark, and *optionally* erase. **The erase opcodes are the only genuinely missing piece**, and they remain on the unsafe list. -### The session is server-driven +### 🔑🔑 CAPTURED 2026-10-14 — a complete, working ACH session + +MITM between UM12947's modem and THOR 1.5.0.29. **101 request frames, 101 +responses, 0 bad checksums, 34,872 B of event data in 65 seconds.** +`bridges/captures/mitm-october/ach_mitm_20261014_182612/` + +🔑 **Every command in a real ACH session is one we already implement — except +one.** + +| SUB | name | count | +|---|---|---| +| `0x5B` | POLL | 36 | +| `0x5A` | BULK_DOWNLOAD | 27 | +| `0x49` | STATE | 10 | +| `0x0C` | EVENT_RECORD | 8 | +| `0x1F` | EVENT_NEXT | 7 | +| `0x06` | STORAGE_RANGE | 4 | +| `0x1C` | MONITOR_STATUS | 3 | +| `0x93` | ARM_EVENT | 3 | +| `0x15` | SERIAL | 1 | +| `0x1E` | EVENT_FIRST | 1 | +| **`0xA2`** | **see below** | **1** | + +Session shape — note THOR polls between *every* command: + +``` +POLL POLL SERIAL POLL STORAGE_RANGE POLL MONITOR_STATUS POLL STATE POLL +ARM_EVENT EVENT_FIRST POLL EVENT_RECORD POLL STATE POLL + [ EVENT_NEXT POLL EVENT_RECORD POLL STATE POLL BULK_DOWNLOAD... ] x n +POLL STORAGE_RANGE POLL STATE POLL 0xA2 +``` + +#### ⚠⚠ `SUB 0xA2` ends a call-home — and COLLIDES with Series III's ERASE + +The session's final command is `0xA2` at `offset = 0xFFFF`, answered `0x5D`. +THOR's log at that instant: + +``` +TX: SENT REQUEST: StartMonitoringAfterCallhome +WARN Switching unit back to monitoring; IP: 63.45.161.30 +SESSION COMPLETED SECCESSFULLY +``` + +So on Series IV, **`0xA2` = exit call-home and resume monitoring.** + +⚠⚠ **On Series III, `0xA2` → `0x5D` is CONFIRM ERASE** — the last step of +`0xA3 → 0x1C → 0x06 → 0xA2`, after which the unit's memory is cleared. +**Same opcode, same response SUB, opposite consequence.** + +That is the most dangerous collision found in this protocol. Any code path shared +between the two families — and `minimateplus` and `micromate` already share a +transport — must dispatch on series *before* `0xA2` goes near a wire. Sending it +to a MiniMate Plus to "end a session" erases it. + +It also corroborates the firmware string found by static analysis in September: +`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`. + +#### ⚠ "Monitor While Calling Home" silently blocks erase — and that fills units + +Manual §11.4.4: a Micromate can call home **while it continues to monitor**, or +**pause monitoring** and send. UM12947 is on the former, which is why this +session logged: + +``` +CANNOT DOWNLOAD MONITOR LOG. The unit is monitoring. +CANNOT DELETE ALL EVENTS. The unit is monitoring. +``` + +⚠ **THOR reports the session as `SESSION COMPLETED SECCESSFULLY` anyway.** The +refusals are INFO lines. From the outside, a unit that is quietly accumulating +looks identical to one being managed correctly. + +**TMI's normal fleet setting is delete-after-download**, and it is not optional: +without it a unit fills up and re-offers every event on every call. So a unit +left on *monitor while calling home* is misconfigured relative to the fleet, and +drifts toward a full buffer on its own. + +🔑 **Design consequence for SFM: a receiver cannot rely on erase to manage +storage.** The erase can fail for a reason the unit considers normal, so the +**server-side high-water mark is load-bearing, not an optimisation** — it is the +only thing preventing a full re-download every session. Series III's +`ach_state.json` (`downloaded_keys` / `max_downloaded_key`) is the pattern; it +has to carry over deliberately. + +🔑 **And it is a detectable fleet-health signal.** "Memory filling *and* deletes +refused" is visible on every call from `0x06`'s event count plus `0x1C`'s memory +fields — worth surfacing, precisely because THOR calls it success. + +#### ⚠ Correction: `0x06` content[4:8] is NOT a constant + +Recorded on 2026-10-01 as "**9** on both units regardless of count — a constant, +not a count". It reads **47** here, four times in one session, where THOR's log +twelve minutes earlier reported **`Monitor Log count: 45`** on the same unit. + +It is almost certainly the **monitor-log record count**. Both units reading 9 +earlier simply meant both held 9 monitor-log records. ⚠ Two samples and a +near-miss (47 vs 45, twelve minutes and an active monitoring session apart), so +treat as a strong candidate rather than settled. + +`content[0:4]` remains the event count — **8** here, consistent. + +#### ⚠ Correction: `SUB 0x49` has a third state value + +Recorded as `0x00` idle / `0x02` monitoring. Throughout this ACH session it reads +**`0x03`**, ten times out of ten — so there is a distinct *in-call-home* state. + +**This is exactly why the rule is "test for non-zero".** A client checking +`== 0x02` would report a unit mid-call-home as idle. + +#### ⚠ THOR rewrites a unit's stored IP from the call-home source + +After this session THOR showed UM12947's connection details as +`TCP: 127.0.0.1 - Port: 9034` — the address the MITM connected *from*. THOR +learns a unit's address from its inbound call, which makes sense for units on +dynamic IPs and means **a relay silently poisons THOR's record of where that unit +lives.** + +### 🔑 Both ACH paths are real — and which one runs depends on timing + +> #### ⚠ Softened 2026-10-14 — "mm_ach_server is built on the wrong model" +> +> An earlier entry concluded the inbound-listener model was wrong because +> `ListenerAchTcp` had never accepted a connection. It has now: +> +> | condition | path taken | +> |---|---| +> | THOR already holds a connection to the unit | `ListenerAchRadioRing` — the ring rides that connection | +> | nothing is connected | the modem **dials out**, `ListenerAchTcp` accepts | +> +> Both are real. The listener model is valid; it simply **loses whenever +> something already holds the modem's single session slot.** That also explains +> every failed probe and relay attempt of 2026-10-14: they were not bugs, they +> were contention with THOR's `UnitWatchDogTimer`, which reconnects continuously. + +### 🔑 Call-home can also be an IN-BAND WAKE SIGNAL, not a dial-out + +From THOR's own ACH log (1.5.0.29, 4,414 lines, UM12947 over an RX55). **This +overturns the model this document has carried since the beginning**, and it +explains every confusing result of the preceding weeks. + +**A Micromate does not dial anybody.** It emits the ASCII string `RADIO RING` +over its serial port, and that text travels up a TCP connection **the server +already has open to the unit**. The server recognises it and starts a session +*on that same connection*. + +``` +17:18:17,268 TcpClientSystemNet #1: RADIO RING IS RECEIVED FROM IP:63.45.161.30 and Port:9034 +17:18:17,268 ListenerAchRadioRing #2 RADIO RING IS DETECTED BY Serial ListenerAchRadioRing +17:18:17,304 ConnectorWorkerThread Process Request: ReadSerialNumber <- who is this? +17:18:18,489 ListenerAchRadioRing #3 RADIO RING UNIT SERIAL NUMBER = UM12947 +17:18:18,490 ListenerAchRadioRing #4 NOTIFICATION IS SENT TO ACH MANAGER +17:18:18,499 ACHManager #8 RADIO RING STARTED A NEW SESSION +``` + +⚠ **`TcpClientSystemNet` is THOR's outbound TCP *client*.** The ring arrives on +the connection THOR itself opened to `unit:9034` — the ordinary call-*up* path. +There is no inbound connection, no dial, nothing to accept. + +**THOR keeps that connection alive deliberately.** `UnitWatchDogTimer` reconnects +to every unit continuously — 1,039 lines of it in 37 minutes. The call-home +mechanism depends on that connection existing. + +#### THOR has a second, unused ACH path + +`ListenerAchTcp` logs `Waiting for a ACH connection on :: Port 12346` — and in +4,414 lines **it never accepted one**. All twelve ACH events came through +`ListenerAchRadioRing`. So the inbound-TCP ACH listener exists (presumably for +units that genuinely dial, on some other modem arrangement) but is not what a +PAD-connected Micromate uses. + +#### What this means for a homebrew receiver + +⚠ **`bridges/mm_ach_server.py` is built on the wrong model for this deployment.** +It listens for an inbound connection, which is `ListenerAchTcp`'s model — the one +THOR never exercises here. The right shape is: + +1. **Hold an outbound connection to each unit** (`unit:9034`), reconnecting as + needed — this is a poller, not a listener +2. **Watch the byte stream for `RADIO RING`** +3. On seeing it, identify the unit (THOR sends `ReadSerialNumber`) and run an + ordinary session on the same socket + +That also explains the single-session contention that dogged every experiment: +**the receiver must hold the modem's one session slot permanently**, so anything +else probing that unit will be met with silence. Those are not separate +problems; holding the slot *is* the design. + +#### The ACH session, from THOR's state machine + +``` +InitializeState ReadEventRecordCount, ReadOperatingMode +CheckEventsCount +DownloadEventState ReadUnitACHStatus, ReadEventAddressFirst/Next, + SaveEventByAddress +DownloadMonitorLogState ReadMonitorLogRecordCount +DownloadScheduler +SetDateTimeState +DeleteEventState / DeleteAllEventsState / DeleteMonitorLogState +CheckEventWhileMonitoringBeforeEndingState / ...AfterDownloadingState +LoopState +EndWithSuccessState / EndWithCommunicationErrorState / EndState +``` + +Request counts over the log: `ReadUnitACHStatus` 53, `SaveEventByAddress` 47, +`ReadEventAddressNext` 43, `ReadOperatingMode` 10, `ReadEventRecordCount` 10, +`ReadEventAddressFirst` 4, `StartMonitoringAfterCallhome` 3, +`ReadMonitorLogRecordCount` 3. + +`StartMonitoringAfterCallhome` matches the firmware string +`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` found by static analysis in +September — independent corroboration that the unit resumes monitoring when the +server finishes. + +✅ **`ReadEventRecordCount` returned `Event count: 19`** — corroborating the +`SUB 0x06` event-count finding from a completely different direction. + +⚠ Events are addressed as `90000001` here (`length: 4076`), where the chain walk +we implemented returns `055d4a81` for an event of exactly that length. Same +event, different address space — unexplained, and worth care before assuming our +keys and THOR's addresses are interchangeable. + +### Superseded 2026-10-14 — "THOR's ACH side is POLL" + +First capture of THOR's half of a Micromate call-home, via `ach_mitm.py` between +UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070. + +``` +unit -> THOR 60 B " \nRADIO RING \nRADIO RING \nRADIO RING \nRADIO RING" +THOR -> unit 84 B 4 x 41 02 10 10 00 5b 00 00 30 00 00 00 00 00 00 00 00 00 00 9b 03 +``` + +**THOR sends `POLL` (`SUB 0x5B`, offset `0x0030`) — and nothing else.** Four +times over ~21 seconds, then it gives up. It does **not** send a greeting, does +not answer the `RADIO RING`, does not send `CONNECT`, and does not wait to be +spoken to beyond its initial silence. + +🔑 **That POLL is byte-identical to the one `micromate.protocol` builds.** +Verified: `build_request(SUB_POLL, 0x0030)` reproduces all four frames exactly. + +**So the ACH session is pull, and our receiver already implements it correctly.** +`bridges/mm_ach_server.py` does what THOR does. The "inbound call-home session" +was never a separate protocol — it is the ordinary command set on an inbound +socket, exactly as Series III's 72 captured sessions suggested. + +### ⚠ But the unit answered neither — and that is the open problem + +In the same capture the unit sent **only** `RADIO RING`, four times, and never a +protocol frame. THOR polled four times and got nothing. Our own server, in three +earlier attempts the same afternoon, saw the identical thing. + +**The vendor's own software fails the same way we do**, which eliminates the +receiver as a suspect and places the fault between the modem and the unit. + +What is established about that fault: + +| | | +|---|---| +| cellular link | ✅ healthy — TCP connect in 151 ms, outbound dial succeeds | +| modem → us | ✅ bytes arrive | +| unit serial TX | ✅ *something* reaches us — the `RADIO RING` text | +| unit protocol mode | ❌ never entered; no frame ever sent | +| cable | FTDI, physically checked, cold-booted with it attached | +| modem serial config | 115200 8N1, no flow control, PAD/TCP — matches spec | + +⚠ `"RADIO RING"` is **the literal string in this unit's own `0x2C` call-home +config** (the 40-byte dial-string field). Whether the unit emits it or the modem +does is **not yet established** — the cheap disambiguation is to disconnect the +unit and see whether the string still appears. + +**Next step is a config diff, not more protocol work.** The deployed fleet runs +call-home over PAD successfully, so a working unit's modem settings are the +reference. Compare them against this one. Which matches the firmware's state machine and its `CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` /