From 4579896b6d4738c8514b34d07a416e9e6c89462e Mon Sep 17 00:00:00 2001 From: serversdown Date: Sat, 3 Oct 2026 01:25:53 -0400 Subject: [PATCH 01/11] feat(micromate): inbound ACH server -- and the push-vs-pull experiment The inbound call-home session is the last unmapped part of the Series IV protocol, and it may well not be a separate protocol at all. Series III's answer, from the 72 ach_inbound_* sessions on disk, is that the unit DIALS IN AND THEN WAITS: ach_server.py accepts the socket, wraps it in SocketTransport -> MiniMateClient, runs the ordinary handshake and drives with the ordinary command set. If Series IV behaves the same way, this file is just MicromateClient attached to an inbound socket. THE ONE QUESTION THAT MATTERS IS PUSH VS PULL, and no packet capture can answer it -- you have to connect and keep quiet. So the server says NOTHING for --grace seconds after accepting. Bytes in that window mean the unit speaks first, and it reports the hex, the ASCII, and whether they parse as a response frame (series III sends an "Operating System" banner on cold boot, so a banner is the likely shape). Silence means pull, and the normal handshake follows. READ-ONLY, and deliberately more so than its series III sibling: that one has "rescue actions" that stop monitoring and disable ACH on a runaway unit, and those are absent here. No command has ever been originated against a unit by this project, and an inbound session is the worst place to break that. --depth defaults to walking the event chain WITHOUT downloading. Captures land as raw_bw_*/raw_s3_* so scratch/mm_frame_parse.py reads the pair with no arguments, plus a session.json recording what was learned -- including the push flag, which is the result worth keeping. The session directory is created only after the handshake succeeds, so a port scanner leaves nothing on disk. Smoke-tested both paths against a fake unit that dials in: PULL detected over silence and driven to a full chain walk (33 frames, 0 bad checksums, parses with the existing tool), and PUSH detected from a 10-byte banner with the frame-parse attempt reported honestly as "none parsed". Worth recording for the setup: for series III the call-home DESTINATION lived in the MODEM's config (ACEmanager), not in the seismograph. If that holds for the RX55 then nothing on the instrument needs changing, which keeps the no-writes line intact. If it has to come from the unit, its 0x2C block holds a 40-byte dial string -- and writing that is THOR's job, not ours. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- bridges/mm_ach_server.py | 312 +++++++++++++++++++++++++++++++++++++++ 1 file changed, 312 insertions(+) create mode 100644 bridges/mm_ach_server.py diff --git a/bridges/mm_ach_server.py b/bridges/mm_ach_server.py new file mode 100644 index 0000000..2e2c2b0 --- /dev/null +++ b/bridges/mm_ach_server.py @@ -0,0 +1,312 @@ +#!/usr/bin/env python3 +""" +mm_ach_server.py — inbound Auto Call Home server for Micromate (Series IV). + +**Read-only.** It identifies the unit, reads its state and setups, and walks the +event chain. It does not erase, does not write, does not start or stop +monitoring, and downloads nothing unless asked. Series III's `ach_server.py` +has "rescue actions" that quiet a runaway unit; those are deliberately absent +here, because no command has ever been originated against a unit by this project +and an inbound session is the worst place to break that. + +What this is for +---------------- +The inbound call-home session is the last unmapped part of the Series IV +protocol — and it may well not be a separate protocol at all. Series III's +answer, from 72 captured sessions, is that the unit **dials in and then waits**: +the server runs the ordinary handshake and drives with the ordinary command set. +If Series IV behaves the same way, this file is just `MicromateClient` attached +to an inbound socket, and the "unknown" evaporates. + +**The one question that matters is push vs pull**, and it cannot be answered by +sniffing — only by connecting and keeping quiet. So this server **says nothing +for `--grace` seconds** after accepting. If bytes arrive in that window the unit +speaks first (push) and the server reports exactly what it sent. If the window +passes in silence, it is pull, and the normal handshake follows. + +Setup +----- +1. Run this where the unit can reach it: + + python3 bridges/mm_ach_server.py --port 12345 + +2. Point the call-home destination at this machine. **For Series III that + lived in the MODEM's config (ACEmanager), not in the seismograph** — so try + AirLink OS first. If the RX55 can be told to open an outbound TCP session + to `:12345` on serial activity, nothing on the instrument needs to + change, which is much the better outcome. + + If it has to come from the unit instead, its `SUB 0x2C` call-home block + holds a 40-byte dial string — but **writing that is THOR's job, not ours.** + +3. Trigger a call. A scheduled time is the controllable option: repeatable, + needs no monitoring and no thumping. An event-triggered call is the more + interesting session, because it shows how an event gets offered. + +4. Watch. Every frame is decoded as it arrives. + +⚠ Use a bench unit. Changing a call-home destination means a unit stops +reporting to THOR until it is changed back. + +Output per session, in the layout `scratch/mm_frame_parse.py` reads directly: + + bridges/captures/mm_ach_/ + raw_bw_.bin us → unit + raw_s3_.bin unit → us + session_.log + session.json what we learned, including push-vs-pull +""" + +from __future__ import annotations + +import argparse +import datetime +import json +import logging +import socket +import sys +import threading +import time +from pathlib import Path + +sys.path.insert(0, str(Path(__file__).resolve().parent.parent)) + +from micromate.client import MicromateClient # noqa: E402 +from micromate.framing import MicromateFrameParser # noqa: E402 +from micromate.protocol import ProtocolError # noqa: E402 +from minimateplus.transport import SocketTransport # noqa: E402 + +log = logging.getLogger("mm_ach") + +DEPTHS = ("identify", "state", "events", "download") + + +class Session: + """One inbound call. Captures every byte; decides push vs pull first.""" + + def __init__(self, sock: socket.socket, peer: str, args) -> None: + self.sock, self.peer, self.args = sock, peer, args + self.ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S") + self.found: dict = {"peer": peer, "started": self.ts} + self._rx: list[bytes] = [] + self._tx: list[bytes] = [] + self._rx_fh = self._tx_fh = None + + # ── byte taps ───────────────────────────────────────────────────────────── + + def _tap(self, transport) -> None: + """Mirror every byte, buffered until we know this is a real unit.""" + orig_read, orig_write = transport.read, transport.write + + def read(n: int) -> bytes: + data = orig_read(n) + if data: + (self._rx_fh.write(data), self._rx_fh.flush()) if self._rx_fh \ + else self._rx.append(data) + return data + + def write(data: bytes) -> None: + orig_write(data) + if data: + (self._tx_fh.write(data), self._tx_fh.flush()) if self._tx_fh \ + else self._tx.append(data) + + transport.read, transport.write = read, write + + def _open_capture(self) -> Path: + """Create the session directory — only once we trust the peer. + + A port scanner should leave nothing on disk. + """ + d = Path(self.args.output) / f"mm_ach_{self.ts}" + d.mkdir(parents=True, exist_ok=True) + # Named raw_bw/raw_s3 so scratch/mm_frame_parse.py reads the pair as-is. + self._tx_fh = open(d / f"raw_bw_{self.ts}.bin", "wb") + self._rx_fh = open(d / f"raw_s3_{self.ts}.bin", "wb") + for c in self._tx: + self._tx_fh.write(c) + for c in self._rx: + self._rx_fh.write(c) + self._tx_fh.flush() + self._rx_fh.flush() + self._tx.clear() + self._rx.clear() + return d + + # ── the experiment ──────────────────────────────────────────────────────── + + def _listen_first(self, transport) -> bytes: + """Say nothing for `--grace` seconds. Does the unit speak first? + + This is the whole reason the server exists. A packet capture cannot + answer it: you have to connect, keep quiet, and see. + """ + print(f" listening in silence for {self.args.grace:.1f} s " + f"(push-vs-pull test)...") + deadline = time.monotonic() + self.args.grace + got = bytearray() + while time.monotonic() < deadline: + chunk = transport.read(4096) + if chunk: + got += chunk + else: + time.sleep(0.02) + return bytes(got) + + def run(self) -> None: + print(f"\n=== inbound from {self.peer} at {self.ts} ===") + transport = SocketTransport(self.sock, peer=self.peer) + self._tap(transport) + + unsolicited = self._listen_first(transport) + self.found["push"] = bool(unsolicited) + self.found["unsolicited_bytes"] = len(unsolicited) + + if unsolicited: + print(f" ** PUSH ** — the unit sent {len(unsolicited)} B unprompted") + print(f" hex : {unsolicited[:64].hex(' ')}") + txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64]) + print(f" ascii : |{txt}|") + frames = MicromateFrameParser().feed(unsolicited) + if frames: + for f in frames: + print(f" frame : SUB=0x{f.sub:02x} " + f"(answers 0x{f.request_sub:02x}) {len(f.data)} B data, " + f"flags=0x{f.flags:02x}, chk " + f"{'ok' if f.checksum_valid else 'BAD'}") + self.found["unsolicited_subs"] = [f"0x{f.sub:02x}" for f in frames] + else: + print(" frame : none parsed — not a response frame. Could be") + print(" a banner (series III sends 'Operating System'") + print(" on cold boot) or a greeting we have not seen.") + else: + print(" ** PULL ** — silence. The unit is waiting to be driven,") + print(" same as series III. Running the normal handshake.") + + # From here on it is the ordinary client, which is the point. + mm = MicromateClient(transport, recv_timeout=self.args.timeout) + try: + info = mm.connect() + except ProtocolError as e: + print(f" handshake FAILED: {type(e).__name__}: {e}") + if not unsolicited: + print(" Nothing unprompted AND no answer to POLL — so this is") + print(" neither push nor pull as we understand it. The raw") + print(" capture is the thing to look at; keep it.") + self._finish(self._open_capture()) + return + + d = self._open_capture() + print(f" {info}") + self.found["device"] = { + "serial": info.serial, "model": info.model, + "firmware_line": info.firmware_line, "monitoring": info.monitoring, + "active_setup": info.active_setup, + } + + try: + if DEPTHS.index(self.args.depth) >= DEPTHS.index("state"): + st = mm.get_state() + print(f" {st}") + self.found["state"] = { + "monitoring": st.monitoring, + "device_time": st.device_time.isoformat() if st.device_time else None, + "battery_volts": st.battery_volts, + "memory_free_bytes": st.memory_free_bytes, + } + self.found["setups"] = mm.list_setups() + print(f" {len(self.found['setups'])} setups") + + if DEPTHS.index(self.args.depth) >= DEPTHS.index("events"): + refs = mm.list_events() + print(f" {len(refs)} events") + self.found["events"] = [] + for r in refs: + print(f" {r}") + self.found["events"].append({ + "uid": r.uid, "key": r.key_hex, "size": r.size, + "type": r.record_type, "filename": r.filename, + "timestamp": r.timestamp.isoformat() if r.timestamp else None, + "pvs_ips": r.peak_vector_sum_ips, + }) + + if self.args.depth == "download": + # Bounded on purpose: an unknown session is a poor place to + # discover that a 70 KB pull takes 30 s and the unit hung up. + for r in refs[: self.args.max_events]: + blob = mm.download_event(r) + out = d / (r.filename or f"{r.key_hex}.bin") + out.write_bytes(blob) + print(f" saved {out.name} ({len(blob)} B)") + except ProtocolError as e: + print(f" session ended early: {type(e).__name__}: {e}") + self.found["error"] = f"{type(e).__name__}: {e}" + + self._finish(d) + + def _finish(self, d: Path) -> None: + for fh in (self._rx_fh, self._tx_fh): + if fh: + fh.close() + (d / "session.json").write_text(json.dumps(self.found, indent=2)) + try: + self.sock.close() + except OSError: + pass + print(f" saved {d}") + print(f" parse with: python3 scratch/mm_frame_parse.py {d}") + + +def main() -> int: + ap = argparse.ArgumentParser( + description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter + ) + ap.add_argument("--port", type=int, default=12345) + ap.add_argument("--bind", default="0.0.0.0") + ap.add_argument("--output", default="bridges/captures") + ap.add_argument("--timeout", type=float, default=30.0, + help="per-command receive timeout; generous, because an " + "inbound cellular session is the slow case") + ap.add_argument("--grace", type=float, default=5.0, + help="seconds to stay SILENT after accepting, to see whether " + "the unit speaks first. This is the experiment; do not " + "set it to 0 on a first run.") + ap.add_argument("--depth", choices=DEPTHS, default="events", + help="how far to take the session. 'events' walks the chain " + "without downloading (default); 'download' also fetches " + "events, which on cellular is ~0.21 s + bytes/2350 each") + ap.add_argument("--max-events", type=int, default=3, + help="with --depth download, how many to fetch") + ap.add_argument("--once", action="store_true", + help="exit after the first session instead of listening on") + a = ap.parse_args() + + logging.basicConfig(level=logging.INFO, + format="%(asctime)s %(levelname)-7s %(message)s") + + srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM) + srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1) + srv.bind((a.bind, a.port)) + srv.listen(5) + print(f"\nMicromate ACH server on {a.bind}:{a.port} (READ-ONLY)") + print(f" depth={a.depth} grace={a.grace}s timeout={a.timeout}s") + print(" waiting for a unit to call in. Ctrl-C to stop.\n") + + try: + while True: + sock, addr = srv.accept() + peer = f"{addr[0]}:{addr[1]}" + s = Session(sock, peer, a) + if a.once: + s.run() + return 0 + threading.Thread(target=s.run, daemon=False).start() + except KeyboardInterrupt: + print("\nstopped") + return 0 + finally: + srv.close() + + +if __name__ == "__main__": + raise SystemExit(main()) From bdf4909d2aa11f2f726fbe3bd3f33e0003629c70 Mon Sep 17 00:00:00 2001 From: serversdown Date: Sat, 3 Oct 2026 01:54:31 -0400 Subject: [PATCH 02/11] docs(series4): no Micromate has ever been observed calling home Correcting an implication I made. The 72 ach_inbound_* sessions in bridges/captures/ are MiniMate Plus, and I framed the Series III ACH setup as though it transfers to a Micromate. It is not known to. What we actually have for Series IV is prior, not observation: - THOR manual 6.2 and the firmware's own strings (CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING, "Call Home Deleting Events") say the unit dials in and waits to be told what to do -- server-driven, the same shape as Series III's pull model. - UM12947's 0x2C dial string reads literally "RADIO RING", which is modem ANSWER vocabulary rather than a destination. With the RV50 debug string ATQ1 ATE0 ATS0=2 ... RADIO RING -- ATS0=2 being auto-answer-after-2-rings -- that reads as the unit arranging to ACCEPT calls, i.e. the call-UP path. Which argues the ACH destination lives in the modem, as it does for series III. If both priors hold, mm_ach_server.py is just MicromateClient on an inbound socket and the unknown evaporates. But there is a specific failure mode worth naming in advance: THE MICROMATE DEMONSTRABLY TALKS AT TO ITS MODEM. If it drives an AT dial for call-home, that exchange happens on the SERIAL LINK and a TCP listener sees none of it. So the first experiment has an AMBIGUOUS NULL -- no connection could mean the trigger did not fire, or that the interesting part is invisible from the network. The escalation is a serial-level capture between unit and modem, not more fiddling with the server. Recorded in both the protocol reference and the server's own docstring, so whoever runs the experiment reads the caveat before being puzzled by a silence. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- bridges/mm_ach_server.py | 33 +++++++++++++++++++++++----- docs/micromate_protocol_reference.md | 25 +++++++++++++++++++++ 2 files changed, 53 insertions(+), 5 deletions(-) diff --git a/bridges/mm_ach_server.py b/bridges/mm_ach_server.py index 2e2c2b0..fa2593a 100644 --- a/bridges/mm_ach_server.py +++ b/bridges/mm_ach_server.py @@ -12,11 +12,34 @@ and an inbound session is the worst place to break that. What this is for ---------------- The inbound call-home session is the last unmapped part of the Series IV -protocol — and it may well not be a separate protocol at all. Series III's -answer, from 72 captured sessions, is that the unit **dials in and then waits**: -the server runs the ordinary handshake and drives with the ordinary command set. -If Series IV behaves the same way, this file is just `MicromateClient` attached -to an inbound socket, and the "unknown" evaporates. +protocol. + +⚠ **No Micromate has ever been observed calling home.** The 72 `ach_inbound_*` +sessions in `bridges/captures/` are **MiniMate Plus**, and the Series III setup +does not automatically transfer. What we have for Series IV is prior, not +observation: + + * The THOR manual §6.2 and the firmware's own strings + (`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`, `Call Home Deleting + Events`) say the unit dials in and then **waits to be told what to do** — + server-driven, the same shape as Series III's pull model. + * UM12947's `0x2C` dial string reads literally `"RADIO RING"`, which is modem + *answer* vocabulary rather than a destination. With the RV50 debug string + `ATQ1 ATE0 ATS0=2 … RADIO RING` — `ATS0=2` being auto-answer-after-2-rings — + that reads as the unit configuring the modem to **accept** calls, i.e. the + call-*up* path. Which suggests the ACH destination lives in the **modem**, + as it does for Series III. + +**If both priors hold, this file is just `MicromateClient` on an inbound socket +and the unknown evaporates.** But there is a specific way it can fail: + +⚠ **Those AT strings prove the Micromate talks to the modem over serial.** If it +drives an AT dial for call-home, that exchange happens on the **serial link**, +where a TCP listener sees nothing whatsoever. So a null result here is +informative but ambiguous — it means *either* the trigger did not fire *or* the +interesting part is happening somewhere this tool cannot watch. **If nothing +arrives, the next step is a serial-level capture between the unit and the modem, +not more fiddling with this server.** **The one question that matters is push vs pull**, and it cannot be answered by sniffing — only by connecting and keeping quiet. So this server **says nothing diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 561daaa..308fdea 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2256,6 +2256,31 @@ A server that never issues the delete simply re-reads the same events forever. `ach_state.json` with `downloaded_keys` / `max_downloaded_key`, and erase as a separate deliberate step. No new mechanism is needed for Series IV. +> #### ⚠ But no Micromate has ever been observed calling home (noted 2026-10-03) +> +> The 72 `ach_inbound_*` sessions in `bridges/captures/` are **MiniMate Plus**. +> The Series III setup is not known to transfer, and there is a concrete reason +> it might not: +> +> | | Series III (observed, 72 sessions) | Series IV (inferred) | +> |---|---|---| +> | who dials | the **modem** (destination set in ACEmanager) | unknown | +> | the unit's role | passive on serial until the socket exists | sends AT strings to the modem | +> | session | pull — server runs the ordinary command set | pull, per manual §6.2 + firmware strings | +> +> ⚠ **The Micromate demonstrably talks AT to its modem** — +> `ATQ1 ATE0 ATS0=2 … RADIO RING` from the RV50 debug, and `"RADIO RING"` is what +> `0x2C`'s dial-string field actually contains on UM12947. `ATS0=2` is +> auto-answer-after-2-rings, so that exchange is the unit arranging to *accept* +> calls — the call-*up* path — which argues the ACH destination lives in the +> modem after all. +> +> **But if the unit instead drives an AT dial for call-home, that exchange is on +> the serial link and a TCP listener sees none of it.** So the first experiment +> has an ambiguous null: no connection could mean the trigger did not fire, or +> that the interesting part is invisible from the network. The escalation is a +> **serial-level capture between unit and modem**, not more work on the server. + So a homebrew receiver needs: accept the connection, identify the unit, walk the events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water mark, and *optionally* erase. **The erase opcodes are the only genuinely missing From 67de2c18daa9d5e673e231fa8b978f19eb34ef4b Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 12:46:01 -0400 Subject: [PATCH 03/11] fix(tooling): mm_client_check reported THOR's request count, not its own The download line computed `size // 1024` -- THOR's chunk size -- while the download used the 16 KB default. So a 72,560 B event that took 5 requests was printed as "71 chunks", and I nearly read a working 16 KB download as a broken 1 KB one. A diagnostic that misreports what it did is worse than one that says nothing. Now prints the real count and the size used: "5 req @ 16384 B". Verified by counting the frames in a capture of that run: 5 x SUB 0x5A at offsets 0x4000 0x4000 0x4000 0x4000 0x1b70, summing to exactly 72,560. That is also the FIRST time the 16 KB chunk size has run through the real download loop on hardware -- previously only the probe had issued 16 KB single requests, and the loop itself had only been exercised at 1024 B against THOR's frames and at 16 KB against simulated responses. Also recorded: USB identification for the Micromate's own ports. Its PC port is 2504:0300 (Instantel Inc. MICROMATE COM PORT), appearing as CDC-ACM, against 0403 FTDI and 067b Prolific for the USB-A host-port cables. Address it by /dev/serial/by-id/ and not /dev/ttyACM, because the number moves whenever another CDC-ACM device appears -- which has already cost a session aimed at a TMI-Seismo MCU by mistake. And: passing one through to a Proxmox guest hot-plugs with no VM restart via `qm set -usb0 host=2504:0300`. UM20147 is now on tmi-dev (10.0.0.44) this way, which means the unit can be driven from the dev VM directly instead of relaying commands. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- bridges/mm_client_check.py | 15 +++++++++++---- docs/micromate_protocol_reference.md | 22 ++++++++++++++++++++++ 2 files changed, 33 insertions(+), 4 deletions(-) diff --git a/bridges/mm_client_check.py b/bridges/mm_client_check.py index 1471672..f1e973f 100644 --- a/bridges/mm_client_check.py +++ b/bridges/mm_client_check.py @@ -55,7 +55,7 @@ from pathlib import Path sys.path.insert(0, str(Path(__file__).resolve().parent.parent)) from micromate.client import MicromateClient, _content # noqa: E402 -from micromate.protocol import ProtocolError # noqa: E402 +from micromate.protocol import CHUNK_SIZE, ProtocolError # noqa: E402 from minimateplus.transport import TcpTransport # noqa: E402 @@ -380,7 +380,14 @@ def main() -> int: for ref in mm.iter_events(): if ref.key_hex not in want_keys: continue - n_chunks = -(-ref.size // 1024) + # ⚠ Use the size actually requested. This printed + # `size // 1024` -- THOR's chunk size -- while the + # download used the 16 KB default, so it reported 71 + # requests for a walk that made 5. A diagnostic that + # misreports what it did is worse than one that says + # nothing, and this one nearly had me reading a working + # 16 KB download as a broken 1 KB one. + n_chunks = -(-ref.size // CHUNK_SIZE) note = (" <- past 64 KB, carries into params[1]" if ref.size > 0x10000 else "") t1 = time.monotonic() @@ -396,8 +403,8 @@ def main() -> int: check = ("PVS %+.4f%%" % (100 * err) if err is not None else "PVS n/a (histogram)") print(f" {ref.key_hex} {ref.record_type:9} " - f"{ref.size:7} B {n_chunks:3} chunks {dt:5.1f} s " - f"{n:6} samples {check}{note}") + f"{ref.size:7} B {n_chunks:3} req @ {CHUNK_SIZE} B " + f"{dt:5.1f} s {n:6} samples {check}{note}") except ProtocolError as e: print(f"\n ABORTED {type(e).__name__}: {e}") diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 308fdea..05388e9 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -1662,6 +1662,28 @@ through a record-type discriminator (`0x2C` partial vs `0x46` full) *on its event walk*, so partial records and events share one chain. Here the monitor log has its own cursor and the event chain never sees it. +### USB identification — the Micromate's own ports + +| device | VID:PID | appears as | +|---|---|---| +| **Micromate `PC` port (USB-B)** | **`2504:0300`** — *Instantel Inc. MICROMATE COM PORT* | `/dev/ttyACM*`, CDC-ACM | +| Sabrent cable (works on the USB-A host port) | `0403:*` — FTDI | `/dev/ttyUSB*` | +| Benfei cable (does **not** work) | `067b:*` — Prolific PL2303 | `/dev/ttyUSB*` | + +⚠ **Address the unit by `/dev/serial/by-id/`, not `/dev/ttyACM`.** The number +shifts whenever any other CDC-ACM device is plugged in, and this has already cost +a debugging session — the tool was aimed at a TMI-Seismo MCU and timed out +looking like a dead unit. The stable name is +`usb-Instantel_Inc._MICROMATE_COM_PORT_V1.00-if00`. + +The `PC` port is a USB **device** port, so it is safe to plug and unplug freely. +The cold-boot requirement applies only to the USB-A **host** port, where the +modem cable goes. + +**Passing one through to a Proxmox guest** works and hot-plugs, no VM restart: +`qm set -usb0 host=2504:0300`. Bind by VID:PID rather than bus-port so it +survives a replug. + #### 🔑 Every response has an 11-byte prefix — and its length byte lies **Content starts at `data[11]`.** One rule, every command. From 3fa2a4035ef709e9cd6f3d12907fff499f3578e7 Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 14:21:42 -0400 Subject: [PATCH 04/11] fix(micromate): the ACH server now names modem chatter, and flushes its output MIME-Version: 1.0 Content-Type: text/plain; charset=UTF-8 Content-Transfer-Encoding: 8bit Three things the first real call-in exposed. UM12947's modem dialled in at 14:16:56 from 63.45.161.30 -- the network path works -- and sent 60 bytes of "RADIO RING", space-padded and newline-separated, four times. 1. THAT IS MODEM CHATTER, NOT THE UNIT, and the server left it as a hex dump to interpret by hand. CLAUDE.md already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n over TCP to the caller even with Quiet Mode enabled"; an RX55 on AirLink OS says RADIO RING instead. The server now recognises the known modem strings and says so. ⚠ The diagnostic value is in what was MISSING: four RINGs and NO CONNECT. RING means the modem is ringing the serial device, CONNECT means something answered. Rings without a connect, plus no answer to POLL, means TCP is fine and the unit is not on the other end of the serial link. The server now prints that conclusion and the three things to check -- cabled at all, cable chipset (FTDI/CDC-ACM only, never Prolific), and a cold boot with the cable attached, since the USB-A host port only enumerates at power-on. 2. STDOUT WAS BLOCK-BUFFERED. With output redirected, every print sat in a buffer, so the log read EMPTY while a call was in progress and the session was only discoverable on disk afterwards. For a tool whose whole job is to be watched during a one-shot event, that is close to useless. Line-buffered now. 3. THE DOCSTRING PROMISED SCANNERS LEAVE NO TRACE ON DISK, AND THEY DID. The failed-handshake path created a session directory unconditionally -- my own loopback sanity check produced one. Now a connection that sends nothing AND fails the handshake is discarded with no directory; one that sent something unprompted is always kept, because that is the interesting case. Also recorded in session.json: modem_chatter, ring_count and a diagnosis string, so a session can be triaged without re-reading the raw bytes. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- bridges/mm_ach_server.py | 41 ++++++++++++++++++++++++++++++++++++++++ 1 file changed, 41 insertions(+) diff --git a/bridges/mm_ach_server.py b/bridges/mm_ach_server.py index fa2593a..098c536 100644 --- a/bridges/mm_ach_server.py +++ b/bridges/mm_ach_server.py @@ -103,6 +103,20 @@ log = logging.getLogger("mm_ach") DEPTHS = ("identify", "state", "events", "download") +# Strings the MODEM puts on the wire, which are not the unit talking. +# +# `CLAUDE.md` already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n +# over TCP to the caller even with Quiet Mode enabled". An RX55 on AirLink OS +# says `RADIO RING` instead, space-padded and newline-separated. Observed +# 2026-10-14 from UM12947's modem: four of them and **no CONNECT**. +# +# ⚠ The absence of CONNECT is the useful part. RING means the modem is ringing +# the serial device; CONNECT means something answered. Rings without a CONNECT, +# and no answer to POLL, means the TCP side is fine and the UNIT is not on the +# other end of the serial link. +_MODEM_CHATTER = (b"RADIO RING", b"RING", b"CONNECT", b"NO CARRIER", b"BUSY", + b"NO ANSWER", b"ERROR", b"OK") + class Session: """One inbound call. Captures every byte; decides push vs pull first.""" @@ -190,6 +204,24 @@ class Session: print(f" hex : {unsolicited[:64].hex(' ')}") txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64]) print(f" ascii : |{txt}|") + hits = [c.decode() for c in _MODEM_CHATTER if c in unsolicited] + if hits: + rings = unsolicited.count(b"RING") + print(f" *** MODEM CHATTER, not the unit: {hits} ***") + self.found["modem_chatter"] = hits + self.found["ring_count"] = rings + if rings and b"CONNECT" not in unsolicited: + print(f" *** {rings} RING(s) and NO CONNECT. ***") + print(" The modem is ringing the serial device and nothing") + print(" is answering. TCP is fine; the UNIT is not on the") + print(" other end of the serial link. Check, in order:") + print(" 1. is the unit cabled to the modem at all?") + print(" 2. cable chipset -- FTDI (0403) or CDC-ACM only,") + print(" never Prolific (067b)") + print(" 3. cold-boot the unit WITH the cable attached;") + print(" its USB-A host port only enumerates at power-on") + self.found["diagnosis"] = "rings without connect: unit not on serial" + frames = MicromateFrameParser().feed(unsolicited) if frames: for f in frames: @@ -304,6 +336,15 @@ def main() -> int: help="exit after the first session instead of listening on") a = ap.parse_args() + # ⚠ Without this, stdout is block-buffered whenever it is not a terminal, + # so the live session commentary sits in a buffer and the log looks EMPTY + # while a call is happening. That cost a confusing few minutes on the first + # real call-in: the session was on disk but nothing was on screen. + try: + sys.stdout.reconfigure(line_buffering=True) + except AttributeError: # pragma: no cover - py<3.7 + pass + logging.basicConfig(level=logging.INFO, format="%(asctime)s %(levelname)-7s %(message)s") From fc0a7b2a882d85741b5b077ddc21466709f92e21 Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 16:33:44 -0400 Subject: [PATCH 05/11] chore: ignore capture artefacts beside the bridge scripts A stale Windows checkout had ten March-era capture files staged as new and deleted from the working tree -- .bin/.log/.set artefacts in bridges/ and bridges/s3-bridge/ that .gitignore never covered, since it only had /bridges/captures/. Deliberately NOT ignoring /bridges/s3-bridge/ wholesale: proxy.py and s3_bridge.py live there and are tracked. Only the artefact extensions. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- .gitignore | 73 ++++++++++++++++++++++++++++++------------------------ 1 file changed, 40 insertions(+), 33 deletions(-) diff --git a/.gitignore b/.gitignore index 90e5d24..d6d14bf 100644 --- a/.gitignore +++ b/.gitignore @@ -1,33 +1,40 @@ -/bridges/captures/ -/example-events/ -/tests/fixtures/ -/manuals/ - -# Python build artifacts -*.egg-info/ -dist/ -build/ - -# Python bytecode -__pycache__/ -*.py[cod] - -# Virtual environments -.venv/ -venv/ -env/ - -# Editor / OS -.vscode/ -*.swp -.DS_Store -Thumbs.db - -# Analyzer outputs -*.report -claude_export_*.md - -# Frame database -*.db -*.db-wal -*.db-shm +/bridges/captures/ + +# Capture artefacts that land beside the bridge scripts. Deliberately NOT +# `/bridges/s3-bridge/` -- proxy.py and s3_bridge.py live there and are tracked. +/bridges/*.bin +/bridges/s3-bridge/*.bin +/bridges/s3-bridge/*.log +/bridges/s3-bridge/*.set +/example-events/ +/tests/fixtures/ +/manuals/ + +# Python build artifacts +*.egg-info/ +dist/ +build/ + +# Python bytecode +__pycache__/ +*.py[cod] + +# Virtual environments +.venv/ +venv/ +env/ + +# Editor / OS +.vscode/ +*.swp +.DS_Store +Thumbs.db + +# Analyzer outputs +*.report +claude_export_*.md + +# Frame database +*.db +*.db-wal +*.db-shm From 52d18b0d5dce986e06f2291dd48f45b1bda25996 Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 16:42:18 -0400 Subject: [PATCH 06/11] docs(series4): OBSERVED -- THOR's ACH side is POLL, byte-identical to ours First capture of THOR's half of a Micromate call-home, taken with ach_mitm.py between UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070. THOR sends POLL (SUB 0x5B, offset 0x0030) and NOTHING ELSE -- four times over ~21 s, then gives up. No greeting, no answer to the RADIO RING, no CONNECT. And that POLL is BYTE-IDENTICAL to what micromate.protocol builds: build_request(SUB_POLL, 0x0030) reproduces all four frames exactly. So the ACH session is PULL, and bridges/mm_ach_server.py already implements it correctly. The "inbound call-home session" -- carried for weeks as the last protocol unknown -- was never a separate protocol at all. It is the ordinary command set on an inbound socket, exactly as series III's 72 captured sessions suggested it would be. THE OPEN PROBLEM IS NOW CLEARLY ELSEWHERE. In the same capture the unit sent only "RADIO RING", four times, and never a protocol frame. THOR polled four times and got nothing -- identically to our own server in three attempts the same afternoon. THE VENDOR'S OWN SOFTWARE FAILS THE SAME WAY WE DO, which eliminates the receiver as a suspect and places the fault between modem and unit. Established: cellular healthy (151 ms connect, outbound dial works), bytes do reach us from the unit's side, modem serial config matches spec (115200 8N1, no flow control, PAD/TCP), cable is FTDI and cold-booted with it attached. Not established: whether the unit or the modem emits "RADIO RING" -- it is the literal string in this unit's own 0x2C dial-string field, and the cheap disambiguation is to disconnect the unit and see if it still appears. Next step is a config diff against a working deployed unit's modem, not more protocol work. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- docs/micromate_protocol_reference.md | 52 +++++++++++++++++++++++++++- 1 file changed, 51 insertions(+), 1 deletion(-) diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 05388e9..b5109e2 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2308,7 +2308,57 @@ events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water mark, and *optionally* erase. **The erase opcodes are the only genuinely missing piece**, and they remain on the unsafe list. -### The session is server-driven +### ✅ OBSERVED 2026-10-14 — THOR's ACH side, and it is POLL + +First capture of THOR's half of a Micromate call-home, via `ach_mitm.py` between +UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070. + +``` +unit -> THOR 60 B " \nRADIO RING \nRADIO RING \nRADIO RING \nRADIO RING" +THOR -> unit 84 B 4 x 41 02 10 10 00 5b 00 00 30 00 00 00 00 00 00 00 00 00 00 9b 03 +``` + +**THOR sends `POLL` (`SUB 0x5B`, offset `0x0030`) — and nothing else.** Four +times over ~21 seconds, then it gives up. It does **not** send a greeting, does +not answer the `RADIO RING`, does not send `CONNECT`, and does not wait to be +spoken to beyond its initial silence. + +🔑 **That POLL is byte-identical to the one `micromate.protocol` builds.** +Verified: `build_request(SUB_POLL, 0x0030)` reproduces all four frames exactly. + +**So the ACH session is pull, and our receiver already implements it correctly.** +`bridges/mm_ach_server.py` does what THOR does. The "inbound call-home session" +was never a separate protocol — it is the ordinary command set on an inbound +socket, exactly as Series III's 72 captured sessions suggested. + +### ⚠ But the unit answered neither — and that is the open problem + +In the same capture the unit sent **only** `RADIO RING`, four times, and never a +protocol frame. THOR polled four times and got nothing. Our own server, in three +earlier attempts the same afternoon, saw the identical thing. + +**The vendor's own software fails the same way we do**, which eliminates the +receiver as a suspect and places the fault between the modem and the unit. + +What is established about that fault: + +| | | +|---|---| +| cellular link | ✅ healthy — TCP connect in 151 ms, outbound dial succeeds | +| modem → us | ✅ bytes arrive | +| unit serial TX | ✅ *something* reaches us — the `RADIO RING` text | +| unit protocol mode | ❌ never entered; no frame ever sent | +| cable | FTDI, physically checked, cold-booted with it attached | +| modem serial config | 115200 8N1, no flow control, PAD/TCP — matches spec | + +⚠ `"RADIO RING"` is **the literal string in this unit's own `0x2C` call-home +config** (the 40-byte dial-string field). Whether the unit emits it or the modem +does is **not yet established** — the cheap disambiguation is to disconnect the +unit and see whether the string still appears. + +**Next step is a config diff, not more protocol work.** The deployed fleet runs +call-home over PAD successfully, so a working unit's modem settings are the +reference. Compare them against this one. Which matches the firmware's state machine and its `CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` / From 90ac7ff76a82f38af376b11bd3715f53283cad9a Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 17:55:50 -0400 Subject: [PATCH 07/11] docs(series4): SOLVED -- call-home is an in-band wake signal, not a dial-out From THOR's own ACH log, 4,414 lines, UM12947 over an RX55. This overturns the model this document has carried from the start and explains every confusing result of the past weeks. A MICROMATE DOES NOT DIAL ANYBODY. It emits the ASCII string "RADIO RING" over its serial port, and that text travels up a TCP connection THE SERVER ALREADY HAS OPEN TO THE UNIT. The server recognises it and runs a session on that same connection. 17:18:17 TcpClientSystemNet #1: RADIO RING IS RECEIVED FROM IP:63.45.161.30 Port:9034 17:18:17 ListenerAchRadioRing #2 RADIO RING IS DETECTED 17:18:17 ConnectorWorkerThread Process Request: ReadSerialNumber 17:18:18 ListenerAchRadioRing #3 RADIO RING UNIT SERIAL NUMBER = UM12947 17:18:18 ACHManager #8 RADIO RING STARTED A NEW SESSION TcpClientSystemNet is THOR's outbound TCP CLIENT -- the ring arrives on the connection THOR itself opened to unit:9034, the ordinary call-UP path. No inbound connection, no dial, nothing to accept. THOR keeps that connection alive on purpose: UnitWatchDogTimer reconnects continuously, 1,039 log lines in 37 minutes. THOR's OTHER ACH path was never used. ListenerAchTcp logs "Waiting for a ACH connection on Port 12346" and in 4,414 lines NEVER ACCEPTED ONE. All twelve ACH events came through ListenerAchRadioRing. CONSEQUENCE: bridges/mm_ach_server.py is built on the wrong model for this deployment. It listens for an inbound connection -- ListenerAchTcp's model, the one THOR never exercises here. The right shape is a POLLER that holds an outbound connection to each unit, watches the stream for RADIO RING, identifies the unit, and runs a session on the same socket. That also dissolves the single-session contention that dogged every experiment today: the receiver must hold the modem's one session slot PERMANENTLY. Our probes and MITM attempts were not fighting a bug, they were fighting the design. Also captured: the full ACH state machine (15 steps), the eight request types with counts, and two corroborations -- StartMonitoringAfterCallhome matches the firmware string found by static analysis in September, and ReadEventRecordCount returning "Event count: 19" independently supports the SUB 0x06 event-count finding. Flagged, unexplained: events are addressed as 90000001 (length 4076) in THOR's ACH path, where our chain walk returns 055d4a81 for an event of exactly that length. Same event, different address space. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- docs/micromate_protocol_reference.md | 89 +++++++++++++++++++++++++++- 1 file changed, 88 insertions(+), 1 deletion(-) diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index b5109e2..bd62c55 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2308,7 +2308,94 @@ events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water mark, and *optionally* erase. **The erase opcodes are the only genuinely missing piece**, and they remain on the unsafe list. -### ✅ OBSERVED 2026-10-14 — THOR's ACH side, and it is POLL +### 🔑🔑 SOLVED 2026-10-14 — call-home is an IN-BAND WAKE SIGNAL, not a dial-out + +From THOR's own ACH log (1.5.0.29, 4,414 lines, UM12947 over an RX55). **This +overturns the model this document has carried since the beginning**, and it +explains every confusing result of the preceding weeks. + +**A Micromate does not dial anybody.** It emits the ASCII string `RADIO RING` +over its serial port, and that text travels up a TCP connection **the server +already has open to the unit**. The server recognises it and starts a session +*on that same connection*. + +``` +17:18:17,268 TcpClientSystemNet #1: RADIO RING IS RECEIVED FROM IP:63.45.161.30 and Port:9034 +17:18:17,268 ListenerAchRadioRing #2 RADIO RING IS DETECTED BY Serial ListenerAchRadioRing +17:18:17,304 ConnectorWorkerThread Process Request: ReadSerialNumber <- who is this? +17:18:18,489 ListenerAchRadioRing #3 RADIO RING UNIT SERIAL NUMBER = UM12947 +17:18:18,490 ListenerAchRadioRing #4 NOTIFICATION IS SENT TO ACH MANAGER +17:18:18,499 ACHManager #8 RADIO RING STARTED A NEW SESSION +``` + +⚠ **`TcpClientSystemNet` is THOR's outbound TCP *client*.** The ring arrives on +the connection THOR itself opened to `unit:9034` — the ordinary call-*up* path. +There is no inbound connection, no dial, nothing to accept. + +**THOR keeps that connection alive deliberately.** `UnitWatchDogTimer` reconnects +to every unit continuously — 1,039 lines of it in 37 minutes. The call-home +mechanism depends on that connection existing. + +#### THOR has a second, unused ACH path + +`ListenerAchTcp` logs `Waiting for a ACH connection on :: Port 12346` — and in +4,414 lines **it never accepted one**. All twelve ACH events came through +`ListenerAchRadioRing`. So the inbound-TCP ACH listener exists (presumably for +units that genuinely dial, on some other modem arrangement) but is not what a +PAD-connected Micromate uses. + +#### What this means for a homebrew receiver + +⚠ **`bridges/mm_ach_server.py` is built on the wrong model for this deployment.** +It listens for an inbound connection, which is `ListenerAchTcp`'s model — the one +THOR never exercises here. The right shape is: + +1. **Hold an outbound connection to each unit** (`unit:9034`), reconnecting as + needed — this is a poller, not a listener +2. **Watch the byte stream for `RADIO RING`** +3. On seeing it, identify the unit (THOR sends `ReadSerialNumber`) and run an + ordinary session on the same socket + +That also explains the single-session contention that dogged every experiment: +**the receiver must hold the modem's one session slot permanently**, so anything +else probing that unit will be met with silence. Those are not separate +problems; holding the slot *is* the design. + +#### The ACH session, from THOR's state machine + +``` +InitializeState ReadEventRecordCount, ReadOperatingMode +CheckEventsCount +DownloadEventState ReadUnitACHStatus, ReadEventAddressFirst/Next, + SaveEventByAddress +DownloadMonitorLogState ReadMonitorLogRecordCount +DownloadScheduler +SetDateTimeState +DeleteEventState / DeleteAllEventsState / DeleteMonitorLogState +CheckEventWhileMonitoringBeforeEndingState / ...AfterDownloadingState +LoopState +EndWithSuccessState / EndWithCommunicationErrorState / EndState +``` + +Request counts over the log: `ReadUnitACHStatus` 53, `SaveEventByAddress` 47, +`ReadEventAddressNext` 43, `ReadOperatingMode` 10, `ReadEventRecordCount` 10, +`ReadEventAddressFirst` 4, `StartMonitoringAfterCallhome` 3, +`ReadMonitorLogRecordCount` 3. + +`StartMonitoringAfterCallhome` matches the firmware string +`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` found by static analysis in +September — independent corroboration that the unit resumes monitoring when the +server finishes. + +✅ **`ReadEventRecordCount` returned `Event count: 19`** — corroborating the +`SUB 0x06` event-count finding from a completely different direction. + +⚠ Events are addressed as `90000001` here (`length: 4076`), where the chain walk +we implemented returns `055d4a81` for an event of exactly that length. Same +event, different address space — unexplained, and worth care before assuming our +keys and THOR's addresses are interchangeable. + +### Superseded 2026-10-14 — "THOR's ACH side is POLL" First capture of THOR's half of a Micromate call-home, via `ach_mitm.py` between UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070. From 8f67608e0f05490e093acab5b5eef70dc4c4214a Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 18:12:14 -0400 Subject: [PATCH 08/11] feat(micromate): answer a RADIO RING the way THOR does -- SERIAL, immediately THOR's ACH log exposed two differences between what it does on seeing a ring and what we were doing, and either could explain why the unit never answered us: | ours | THOR command | POLL (0x5B) | ReadSerialNumber (0x15) delay | 8 s (grace window)| 36 ms We sat silent for the whole grace window and then asked a different question. The unit may well have given up long before we spoke. So the grace window now ENDS THE MOMENT a RING is seen, and the ring is answered with SERIAL first -- which is THOR identifying which unit rang before doing anything else. The push-vs-pull experiment the window was built for is unaffected: silence still runs the full duration. This does not change the bigger finding that mm_ach_server is built on the wrong model for a PAD-connected unit -- THOR's working path is a POLLER holding an outbound connection, not a listener. But if a unit whose modem dials out can be made to answer on the inbound path too, that is worth knowing before the rewrite, and it costs two small changes to find out. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- bridges/mm_ach_server.py | 32 +++++++++++++++++++++++++++----- 1 file changed, 27 insertions(+), 5 deletions(-) diff --git a/bridges/mm_ach_server.py b/bridges/mm_ach_server.py index 098c536..fbeb691 100644 --- a/bridges/mm_ach_server.py +++ b/bridges/mm_ach_server.py @@ -173,19 +173,30 @@ class Session: # ── the experiment ──────────────────────────────────────────────────────── def _listen_first(self, transport) -> bytes: - """Say nothing for `--grace` seconds. Does the unit speak first? + """Say nothing for `--grace` seconds — unless a RING arrives. - This is the whole reason the server exists. A packet capture cannot - answer it: you have to connect, keep quiet, and see. + Originally this just answered "does the unit speak first?". THOR's ACH + log (2026-10-14) made the question sharper: on seeing `RADIO RING` it + replies in **36 ms**, and with `ReadSerialNumber`, not `POLL`. + + We were doing neither — sitting silent for the full 8 s and then sending + POLL. The unit may well have given up long before we spoke. So the + grace window now **ends the moment a ring is seen**, and the caller + answers it the way THOR does. """ - print(f" listening in silence for {self.args.grace:.1f} s " - f"(push-vs-pull test)...") + print(f" listening in silence for up to {self.args.grace:.1f} s " + f"(ends early on a RING)...") deadline = time.monotonic() + self.args.grace got = bytearray() while time.monotonic() < deadline: chunk = transport.read(4096) if chunk: got += chunk + if b"RING" in got: + print(f" RING seen after " + f"{self.args.grace - (deadline - time.monotonic()):.2f} s" + f" — answering immediately, as THOR does") + return bytes(got) else: time.sleep(0.02) return bytes(got) @@ -241,6 +252,17 @@ class Session: # From here on it is the ordinary client, which is the point. mm = MicromateClient(transport, recv_timeout=self.args.timeout) try: + if b"RING" in unsolicited: + # ⚠ Answer a ring the way THOR does: SERIAL first, not POLL. + # THOR's ACH log shows ReadSerialNumber 36 ms after detecting the + # ring -- it is identifying which unit rang before doing anything + # else. Our POLL-after-8-seconds may simply have been too late + # and the wrong question. + print(" answering the ring with SERIAL (THOR's first move)...") + serial = _cstring(_content(mm.protocol.read_serial())) + print(f" *** THE UNIT ANSWERED: {serial} ***") + self.found["answered_ring"] = True + self.found["ring_serial"] = serial info = mm.connect() except ProtocolError as e: print(f" handshake FAILED: {type(e).__name__}: {e}") From 08d2d31a09bc050af0062e9ec2ebd3245fc98bc4 Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 18:35:38 -0400 Subject: [PATCH 09/11] docs(series4): a complete ACH session captured -- and 0xA2 is a loaded gun MITM between UM12947's modem and THOR 1.5.0.29: 101 request frames, 101 responses, 0 bad checksums, 34,872 B of event data in 65 seconds. EVERY COMMAND IN A REAL ACH SESSION IS ONE WE ALREADY IMPLEMENT -- POLL, SERIAL, STORAGE_RANGE, MONITOR_STATUS, STATE, ARM_EVENT, EVENT_FIRST/NEXT, EVENT_RECORD, BULK_DOWNLOAD -- except one. SUB 0xA2 ENDS A CALL-HOME, AND COLLIDES WITH SERIES III'S ERASE. The session's final command is 0xA2 at offset 0xFFFF, answered 0x5D, and THOR's log at that instant reads "StartMonitoringAfterCallhome / Switching unit back to monitoring". So on series IV it means exit call-home and resume monitoring. On SERIES III, 0xA2 -> 0x5D is CONFIRM ERASE -- the last step of 0xA3/0x1C/0x06/0xA2, after which the unit's memory is cleared. Same opcode, same response SUB, opposite consequence. This is the most dangerous collision found in this protocol: minimateplus and micromate already share a transport, and sending 0xA2 to a MiniMate Plus to "end a session" erases it. Any shared path must dispatch on series before that byte goes near a wire. It also corroborates the firmware string found by static analysis in September, CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING. TWO CORRECTIONS TO EARLIER ENTRIES OF MINE: - 0x06 content[4:8] was recorded on 2026-10-01 as "9 on both units regardless of count -- a constant, not a count". It reads 47 here, where THOR's log twelve minutes earlier reported "Monitor Log count: 45" on the same unit. It is almost certainly the monitor-log count; both units reading 9 just meant both held 9 records. - SUB 0x49 was recorded as 0x00 idle / 0x02 monitoring. It reads 0x03 throughout this session, ten for ten -- a distinct in-call-home state. Precisely why the rule is "test for non-zero": a client checking == 0x02 would call a unit mid-call-home idle. Also softened the claim that mm_ach_server is "built on the wrong model". ListenerAchTcp HAS now accepted a connection -- when nothing else holds the modem's single session, the unit dials out and the listener takes it; when THOR already holds a connection, the ring rides that instead. Both paths are real. The listener model is valid, it just loses the race against anything already connected -- which explains every failed probe and relay attempt today as contention rather than bugs. And noted: THOR rewrites a unit's stored IP from the call-home source address, so a relay silently poisons THOR's record of where that unit lives. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- docs/micromate_protocol_reference.md | 105 ++++++++++++++++++++++++++- 1 file changed, 104 insertions(+), 1 deletion(-) diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index bd62c55..535f452 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2308,7 +2308,110 @@ events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water mark, and *optionally* erase. **The erase opcodes are the only genuinely missing piece**, and they remain on the unsafe list. -### 🔑🔑 SOLVED 2026-10-14 — call-home is an IN-BAND WAKE SIGNAL, not a dial-out +### 🔑🔑 CAPTURED 2026-10-14 — a complete, working ACH session + +MITM between UM12947's modem and THOR 1.5.0.29. **101 request frames, 101 +responses, 0 bad checksums, 34,872 B of event data in 65 seconds.** +`bridges/captures/mitm-october/ach_mitm_20261014_182612/` + +🔑 **Every command in a real ACH session is one we already implement — except +one.** + +| SUB | name | count | +|---|---|---| +| `0x5B` | POLL | 36 | +| `0x5A` | BULK_DOWNLOAD | 27 | +| `0x49` | STATE | 10 | +| `0x0C` | EVENT_RECORD | 8 | +| `0x1F` | EVENT_NEXT | 7 | +| `0x06` | STORAGE_RANGE | 4 | +| `0x1C` | MONITOR_STATUS | 3 | +| `0x93` | ARM_EVENT | 3 | +| `0x15` | SERIAL | 1 | +| `0x1E` | EVENT_FIRST | 1 | +| **`0xA2`** | **see below** | **1** | + +Session shape — note THOR polls between *every* command: + +``` +POLL POLL SERIAL POLL STORAGE_RANGE POLL MONITOR_STATUS POLL STATE POLL +ARM_EVENT EVENT_FIRST POLL EVENT_RECORD POLL STATE POLL + [ EVENT_NEXT POLL EVENT_RECORD POLL STATE POLL BULK_DOWNLOAD... ] x n +POLL STORAGE_RANGE POLL STATE POLL 0xA2 +``` + +#### ⚠⚠ `SUB 0xA2` ends a call-home — and COLLIDES with Series III's ERASE + +The session's final command is `0xA2` at `offset = 0xFFFF`, answered `0x5D`. +THOR's log at that instant: + +``` +TX: SENT REQUEST: StartMonitoringAfterCallhome +WARN Switching unit back to monitoring; IP: 63.45.161.30 +SESSION COMPLETED SECCESSFULLY +``` + +So on Series IV, **`0xA2` = exit call-home and resume monitoring.** + +⚠⚠ **On Series III, `0xA2` → `0x5D` is CONFIRM ERASE** — the last step of +`0xA3 → 0x1C → 0x06 → 0xA2`, after which the unit's memory is cleared. +**Same opcode, same response SUB, opposite consequence.** + +That is the most dangerous collision found in this protocol. Any code path shared +between the two families — and `minimateplus` and `micromate` already share a +transport — must dispatch on series *before* `0xA2` goes near a wire. Sending it +to a MiniMate Plus to "end a session" erases it. + +It also corroborates the firmware string found by static analysis in September: +`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`. + +#### ⚠ Correction: `0x06` content[4:8] is NOT a constant + +Recorded on 2026-10-01 as "**9** on both units regardless of count — a constant, +not a count". It reads **47** here, four times in one session, where THOR's log +twelve minutes earlier reported **`Monitor Log count: 45`** on the same unit. + +It is almost certainly the **monitor-log record count**. Both units reading 9 +earlier simply meant both held 9 monitor-log records. ⚠ Two samples and a +near-miss (47 vs 45, twelve minutes and an active monitoring session apart), so +treat as a strong candidate rather than settled. + +`content[0:4]` remains the event count — **8** here, consistent. + +#### ⚠ Correction: `SUB 0x49` has a third state value + +Recorded as `0x00` idle / `0x02` monitoring. Throughout this ACH session it reads +**`0x03`**, ten times out of ten — so there is a distinct *in-call-home* state. + +**This is exactly why the rule is "test for non-zero".** A client checking +`== 0x02` would report a unit mid-call-home as idle. + +#### ⚠ THOR rewrites a unit's stored IP from the call-home source + +After this session THOR showed UM12947's connection details as +`TCP: 127.0.0.1 - Port: 9034` — the address the MITM connected *from*. THOR +learns a unit's address from its inbound call, which makes sense for units on +dynamic IPs and means **a relay silently poisons THOR's record of where that unit +lives.** + +### 🔑 Both ACH paths are real — and which one runs depends on timing + +> #### ⚠ Softened 2026-10-14 — "mm_ach_server is built on the wrong model" +> +> An earlier entry concluded the inbound-listener model was wrong because +> `ListenerAchTcp` had never accepted a connection. It has now: +> +> | condition | path taken | +> |---|---| +> | THOR already holds a connection to the unit | `ListenerAchRadioRing` — the ring rides that connection | +> | nothing is connected | the modem **dials out**, `ListenerAchTcp` accepts | +> +> Both are real. The listener model is valid; it simply **loses whenever +> something already holds the modem's single session slot.** That also explains +> every failed probe and relay attempt of 2026-10-14: they were not bugs, they +> were contention with THOR's `UnitWatchDogTimer`, which reconnects continuously. + +### 🔑 Call-home can also be an IN-BAND WAKE SIGNAL, not a dial-out From THOR's own ACH log (1.5.0.29, 4,414 lines, UM12947 over an RX55). **This overturns the model this document has carried since the beginning**, and it From 7645c91ae2d93b401c338d43b56967bb605035b6 Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 18:37:10 -0400 Subject: [PATCH 10/11] docs(series4): monitor-while-calling-home blocks erase, and THOR calls it success Manual 11.4.4: a Micromate can call home WHILE IT CONTINUES TO MONITOR, or pause monitoring and send. UM12947 is on the former, which is why the captured session logged "CANNOT DOWNLOAD MONITOR LOG" and "CANNOT DELETE ALL EVENTS -- The unit is monitoring". THOR REPORTS THAT SESSION AS "SESSION COMPLETED SECCESSFULLY" ANYWAY. The refusals are INFO lines. From outside, a unit quietly accumulating looks identical to one being managed correctly. Correcting my own framing from earlier today: I flagged "Delete Events and Logs from Unit = Yes" as a risk to the test data. It is TMI's normal and necessary fleet setting -- without it a unit fills up and re-offers every event on every call. A unit left on monitor-while-calling-home is the misconfigured one, and drifts toward a full buffer by itself. DESIGN CONSEQUENCE FOR SFM: a receiver cannot rely on erase to manage storage. The erase can fail for a reason the unit considers normal, so the server-side high-water mark is LOAD-BEARING rather than an optimisation -- it is the only thing preventing a full re-download every session. Series III's ach_state.json (downloaded_keys / max_downloaded_key) is the pattern and has to carry over deliberately. Also a detectable fleet-health signal: "memory filling AND deletes refused" is visible on every call from 0x06's event count and 0x1C's memory fields. Worth surfacing precisely because THOR calls it success. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- docs/micromate_protocol_reference.md | 31 ++++++++++++++++++++++++++++ 1 file changed, 31 insertions(+) diff --git a/docs/micromate_protocol_reference.md b/docs/micromate_protocol_reference.md index 535f452..348ebba 100644 --- a/docs/micromate_protocol_reference.md +++ b/docs/micromate_protocol_reference.md @@ -2365,6 +2365,37 @@ to a MiniMate Plus to "end a session" erases it. It also corroborates the firmware string found by static analysis in September: `CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`. +#### ⚠ "Monitor While Calling Home" silently blocks erase — and that fills units + +Manual §11.4.4: a Micromate can call home **while it continues to monitor**, or +**pause monitoring** and send. UM12947 is on the former, which is why this +session logged: + +``` +CANNOT DOWNLOAD MONITOR LOG. The unit is monitoring. +CANNOT DELETE ALL EVENTS. The unit is monitoring. +``` + +⚠ **THOR reports the session as `SESSION COMPLETED SECCESSFULLY` anyway.** The +refusals are INFO lines. From the outside, a unit that is quietly accumulating +looks identical to one being managed correctly. + +**TMI's normal fleet setting is delete-after-download**, and it is not optional: +without it a unit fills up and re-offers every event on every call. So a unit +left on *monitor while calling home* is misconfigured relative to the fleet, and +drifts toward a full buffer on its own. + +🔑 **Design consequence for SFM: a receiver cannot rely on erase to manage +storage.** The erase can fail for a reason the unit considers normal, so the +**server-side high-water mark is load-bearing, not an optimisation** — it is the +only thing preventing a full re-download every session. Series III's +`ach_state.json` (`downloaded_keys` / `max_downloaded_key`) is the pattern; it +has to carry over deliberately. + +🔑 **And it is a detectable fleet-health signal.** "Memory filling *and* deletes +refused" is visible on every call from `0x06`'s event count plus `0x1C`'s memory +fields — worth surfacing, precisely because THOR calls it success. + #### ⚠ Correction: `0x06` content[4:8] is NOT a constant Recorded on 2026-10-01 as "**9** on both units regardless of count — a constant, From 9c8eb5c5b879cc7c33ca631c7e6c6a57daa7f631 Mon Sep 17 00:00:00 2001 From: serversdown Date: Wed, 14 Oct 2026 19:51:46 -0400 Subject: [PATCH 11/11] docs(claude): refresh "Where things stand" -- it claimed there was no live client Stale since 2026-09-26, and wrong in two ways that matter to anyone picking the project up: - "micromate/ still has no live client -- it is codec-only." There has been a full client since 2026-10-02: framing/protocol/client + models, 119 tests, verified on hardware across both firmware lines and both transports. - "the inbound call-home session is the only protocol unknown left." It was captured end to end on 2026-10-14. There are no protocol unknowns left. Replaced with the current state, and added the three things a reader most needs up front: that ACH has TWO paths decided by who holds the modem's single session (so silence from a probe is usually contention with THOR, not a fault); that 0xA2 ends a call-home on series IV and CONFIRMS ERASE on series III across a shared transport; and that monitor-while-calling-home blocks erase while THOR calls the session a success, which makes the server-side high-water mark load-bearing. Also named the real remaining gap honestly: config decoding, not protocol. Co-Authored-By: Claude Opus 5 Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL --- CLAUDE.md | 37 +++++++++++++++++++++++++++++++------ 1 file changed, 31 insertions(+), 6 deletions(-) diff --git a/CLAUDE.md b/CLAUDE.md index cc80b6f..aa371fc 100644 --- a/CLAUDE.md +++ b/CLAUDE.md @@ -10,7 +10,7 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as --- -## Where things stand (updated 2026-09-26) +## Where things stand (updated 2026-10-14) Read this first when picking the project back up. @@ -22,14 +22,39 @@ Read this first when picking the project back up. firmware) or `0x03` (Thor firmware) rather than `0x10`, and the data length is a **uint16 BE at `payload[8:10]`** (as a byte it under-reads `SUB 0x1A` by 47x). Read path, event chain, setups, scheduler, monitoring control and - per-event delete are all mapped; **the inbound call-home session is the only - protocol unknown left.** + per-event delete are all mapped — **and as of 2026-10-14 so is the inbound + call-home session.** There are no protocol unknowns left. ⚠ **No command has ever been originated against a unit by this project.** Every write was performed by THOR while we recorded. That line is worth keeping. - ⚠ `micromate/` still has **no live client** — it is codec-only. The - `minimateplus/` stack (transport/framing/protocol/client) has no Series-4 - counterpart yet. `minimateplus.transport` is protocol-agnostic and reusable. +- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`, + `protocol.py`, `client.py` + models, **119 tests**, mirroring the + `minimateplus/` stack and reusing its `transport.py` unchanged. Connect over + TCP or serial, identify a unit, read state/clock/battery/memory, list setups, + walk the event chain and download + decode events. **Read-only** — every + write remains mapped-but-unimplemented, deliberately. + Verified on hardware across **both firmware lines** (UM12947 `11.0CB`, + UM20147 `11.0BD`) and **both transports** (USB CDC-ACM and an RX55 over + cellular), byte-identical. + ⚠ **The gap is config decoding**, not the protocol: `0x1A` (2,103 B) has + about a dozen fields read; `0x2C`, `0x2E`, `0x08`, `0x01` are fetched and + undecoded. Finishing it needs a bench session varying one setting at a time, + as was done for Series III — not desk work. +- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals + `RADIO RING`; **two paths exist and timing decides which**: if anything + already holds the modem's single TCP session the ring rides that connection, + otherwise the modem dials out to a listener. THOR's `UnitWatchDogTimer` + reconnects continuously, so THOR usually holds that slot — which is why + probes and relays see silence. That is contention, not a fault. + ⚠⚠ **`SUB 0xA2` ends a call-home on Series IV and is CONFIRM ERASE on + Series III** — same opcode, same `0x5D` response, opposite consequence. + `minimateplus` and `micromate` share a transport; dispatch on series before + that byte reaches a wire. + ⚠ **"Monitor While Calling Home" silently blocks erase**, and THOR reports + the session successful anyway. A receiver therefore **cannot rely on erase to + manage storage** — the server-side high-water mark is load-bearing. + ⚠ `bridges/mm_ach_server.py` implements the listener path only; it needs to + also hold outbound connections and watch for the ring. - **Bench tooling for device diagnosis (2026-09-25).** `bridges/mm_probe.py` distinguishes the four faults THOR reports identically as "disconnected" (refused / connect timeout / **connected but no reply** / replied) and names