fix(sfm): a change that fails after the send says so; the audit row records sent + states; S3 unknown states refused

Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.

- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
  (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
  message says the frame was sent and names the audit record -- the ring in
  place of the ack, the four lost-ack follow-ups, and the three read-back
  paths.  Series4Session releases the line on it.  Every audit finish goes
  through one helper; a finish that fails is AuditIncomplete (500) and still
  says what happened to the unit.  The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
  unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
  in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
  (pre_send = read_unsolicited, one 10 ms transport read).  That is a
  CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
  other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
  proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
  scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
  micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
  docstrings).  "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
  rename, serial-cache and short-0x49 tests, _RUN_STATES comment.

Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill.  No codec change, TOOL_VERSION unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-23 19:16:45 -04:00
1 parent ac33c8ffa4
commit 8f68b09f5e
18 files changed
+806 -107

No files matched your search

+25 -7
View File
@@ -32,10 +32,12 @@ Read this first when picking the project back up.
the setup rewrite, reproduced byte for byte against THOR's captured frames.
`bridges/mm_dry_run.py` prints a write's planned frames from a live unit's
reads (run on UM20147: sizes equal UM12947's). `MicromateProtocol._send`
refuses every write opcode except one start/stop plan at a time through `execute()`, on a connection with a fresh Micromate reply, and `0xA2` always, so
"no command has ever been originated against a unit" is still true and is now
enforced in `micromate/` (its `_send` gate); the Series-3 `minimateplus`
stack and raw-socket bench bridges are outside it. The reproduction's
refuses every write opcode except one start/stop plan at a time through
`execute()`, on a connection with a fresh Micromate reply, and refuses `0xA2`
always. The only transmit path for a write is `execute()`, reached only from
SFM's serial-named start/stop routes through `sfm/device_access` (identity,
state, audit, read-back, never retried); the Series-3 `minimateplus` stack
and raw-socket bench bridges are outside the gate. The reproduction's
breadth is one distinct input per block (the five pushes share the same name,
prefs and trigger block).
- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`,
@@ -121,6 +123,16 @@ Read this first when picking the project back up.
5 events, a waveform that verified, a histogram, one call-up for the whole
sequence. ⚠ The MiniMate header walk is **unproven on a unit; a MiniMate
bench check is owed before the branch merges.** Next: 1c (webapp).
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built and
reviewed offline; the first live send is pending at the bench.** Both
series go through one safety core, `sfm/device_access/change.py`: a fresh
identity read, the run state (calling home or never measured is refused),
`dry_run` (the exact frames, nothing sent), a row in the new
`device_commands` audit table (`GET /db/device_commands`; `sent` says whether
a frame went out, `states` keeps every read), one send never retried, then a
read-back. The HTTP status is an allow-list -- only a dry run, a skip or a
send read back as made is a 200 -- and a failure after the send says so and
names its audit record.
- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals
`RADIO RING`; **two paths exist and timing decides which**: if anything
already holds the modem's single TCP session the ring rides that connection,
@@ -1429,14 +1441,19 @@ GET /device/event?host=1.2.3.4&tcp_port=9034&index=0
GET /device/monitor/status?host=1.2.3.4&tcp_port=9034 ← battery, memory, mode
POST /device/monitor/start?host=1.2.3.4&tcp_port=9034 ← start recording
POST /device/monitor/stop?host=1.2.3.4&tcp_port=9034 ← stop recording
POST /device/monitor/start?serial=UM20147&host=...&tcp_port=...&dry_run=&even_if_already= ← audited start, either series
POST /device/monitor/stop?serial=UM20147&host=...&tcp_port=...&dry_run=&even_if_already= ← audited stop, either series
GET /device/settings?serial=UM20147&host=1.2.3.4&tcp_port=9034 ← shared-model settings, either series
POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Series-4 line
```
`serial=` (UM = Series 4, BE/BA = Series 3) on `/device/info`, `/connect`,
`/monitor/status`, `/settings` returns the shared model, uncached. A `UM` serial on any
other `/device/*` route is 501; any request taking the legacy Series-3 path at a held
Series-4 address is 409.
`/monitor/status`, `/settings` returns the shared model, uncached; on `/events` and
`/events/download` it lists and downloads by `event_id`; on `/monitor/start` and
`/monitor/stop` it runs the audited change (`dry_run=true` returns the frames and sends
nothing; `even_if_already=true` sends even when the unit is already in that state). A
`UM` serial on any other `/device/*` route is 501; any request taking the legacy
Series-3 path at a held Series-4 address is 409.
SFM must run a single uvicorn worker (locks and held lines are per process).
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).
@@ -1449,6 +1466,7 @@ GET /db/events?serial=BE11529&from_dt=&to_dt=&limit= ← triggered events, ne
GET /db/monitor_log?serial=BE11529&from_dt=&to_dt= ← monitoring intervals, newest first
GET /db/sessions?serial=BE11529&limit=50 ← ACH call-home sessions, newest first
PATCH /db/events/{id}/false_trigger?value=true ← flag/unflag false triggers
GET /db/device_commands?serial=UM20147&limit=100 ← start/stop audit trail (sent, states), newest first
```
DB file: `bridges/captures/seismo_relay.db` (default; override with `--db-path` at startup).