fix(sfm): a Series-4 record whose timestamp did not decode is not called stale
Mirrors the Series-3 fix (F3): an unreadable 0C timestamp is a decode or comms fault, not proof the unit was erased. Nothing is downloaded. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
67a0fece34
commit
a130107fdf
2 files changed
+15
No files matched your search
@@ -282,6 +282,10 @@ def s4_download_event(client: Any, serial: str, key: bytes, stamp: Optional[str]
|
||||
if ref.key != key:
|
||||
continue
|
||||
found = stamp_of(ref.timestamp)
|
||||
if stamp is not None and found is None:
|
||||
raise MalformedReply(
|
||||
f"could not read event {key.hex()}'s record (0C) timestamp to confirm it "
|
||||
"is the one listed -- not downloaded; try again")
|
||||
if stamp is not None and found != stamp:
|
||||
raise StaleEvent(
|
||||
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
|
||||
|
||||
Reference in new issue