fix(micromate): the write ceiling is enforced at the wire; allowed_writes retired; execute takes only real plans

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-23 16:06:24 -04:00
1 parent 8daf413fe3
commit a90b8158b6
5 files changed
+150 -40

No files matched your search

+2 -1
View File
@@ -2,7 +2,8 @@
One place, as the parity spec requires. The gate is an ALLOWLIST: a SUB is
transmitted only if it is a catalogued read (READ_SUBS) or a catalogued write
this connection was explicitly allowed. An unknown SUB is refused -- clock-set
that arrives through `MicromateProtocol.execute` (one call's permission, capped at
ENABLEABLE_WRITES; the connection itself holds none). An unknown SUB is refused -- clock-set
and delete-all have Series-IV opcodes nobody has catalogued yet, and "unknown
means read" is the wrong default. `MicromateProtocol._send` consults it
on every outgoing frame, so a write cannot reach a unit by a path nobody
+27 -23
View File
@@ -7,8 +7,8 @@ knows frames, offsets and sequencing, and nothing about what a field means.
Scope: **reads only on the wire, enforced** (in this package: the Series-3
`minimateplus` stack and raw-socket bench bridges are outside the gate). Every outgoing frame passes
`micromate.opcodes.check_transmit()` in `_send`: a write opcode is refused
unless this connection was constructed with it in `allowed_writes` (nothing in
the codebase does so yet), and `0xA2` -- CONFIRM ERASE on Series III -- is
unless it arrives through `execute()` (the connection itself holds no write
permission), and `0xA2` -- CONFIRM ERASE on Series III -- is
refused always. The gate is an allowlist: a SUB not catalogued in
`opcodes` (read or write) is refused as unknown. No command has ever been originated against a unit by this
project; every write in ``docs/micromate_protocol_reference.md`` was performed
@@ -47,7 +47,7 @@ import logging
import math
import struct
import time
from typing import Optional
from typing import TYPE_CHECKING, Optional
from minimateplus.transport import BaseTransport
@@ -57,6 +57,9 @@ from .framing import (
)
from .opcodes import ENABLEABLE_WRITES, WRITE_SUBS, OpcodeRefused, check_transmit
if TYPE_CHECKING:
from .writes import WritePlan
log = logging.getLogger(__name__)
DEFAULT_RECV_TIMEOUT = 10.0
@@ -255,13 +258,9 @@ class MicromateProtocol:
transport: BaseTransport,
recv_timeout: float = DEFAULT_RECV_TIMEOUT,
strict_checksums: bool = True,
allowed_writes: frozenset = frozenset(),
) -> None:
"""
Args:
allowed_writes: write SUBs this connection may transmit. Empty by
default -- every write opcode in `micromate.opcodes` is refused
at `_send`, and `0xA2` is refused whatever this says.
strict_checksums: raise on a bad checksum. **Defaults to True,
unlike the Series III sibling**, which logs and continues
because its parser cannot reliably tell an inner-frame
@@ -278,13 +277,6 @@ class MicromateProtocol:
self._transport = transport
self._recv_timeout = recv_timeout
self._strict = strict_checksums
self._allowed_writes = frozenset(allowed_writes)
unknown = self._allowed_writes - set(WRITE_SUBS)
if unknown:
raise ValueError(
"allowed_writes may only name catalogued write SUBs; not in "
"micromate.opcodes.WRITE_SUBS: "
+ ", ".join(f"0x{x:02X}" for x in sorted(unknown)))
self._parser = MicromateFrameParser()
self._pending: list[MicromateFrame] = []
self.last_flags: Optional[int] = None
@@ -526,13 +518,20 @@ class MicromateProtocol:
# so anything already buffered when we send is by definition stale, and
# `expected_sub` would reject it anyway — better to discard it here than
# to raise a confusing UnexpectedResponse one command later.
return self._request(build_request(sub, offset, params), 0xFF - sub,
timeout=timeout)
def _request(self, frame: bytes, expected_sub: int, *, timeout: Optional[float] = None,
permit: frozenset = frozenset()) -> MicromateFrame:
"""Clean slate, send one frame, receive its reply. The one sequence
every exchange -- read or execute -- goes through."""
self._parser.reset()
self._pending.clear()
self._send(build_request(sub, offset, params))
return self._recv_one(expected_sub=0xFF - sub, timeout=timeout,
self._send(frame, permit=permit)
return self._recv_one(expected_sub=expected_sub, timeout=timeout,
reset_parser=False)
def execute(self, plan) -> list:
def execute(self, plan: "WritePlan") -> list[MicromateFrame]:
"""Transmit a `micromate.writes.WritePlan` -- the only write path.
Permission is granted for this call alone, one step at a time, and only
@@ -541,7 +540,11 @@ class MicromateProtocol:
is awaited before the next is sent. Never retries: a timeout raises,
and what happened is the caller's to find out by reading the unit back.
"""
beyond = plan.subs - ENABLEABLE_WRITES
# Deferred: writes -> setup_block -> protocol would be circular at import.
from .writes import WritePlan
if not isinstance(plan, WritePlan):
raise TypeError(f"execute takes a WritePlan, got {type(plan).__name__}")
beyond = {st.sub for st in plan.steps} - ENABLEABLE_WRITES
if beyond:
raise OpcodeRefused(
"plan holds SUB(s) above the write ceiling: "
@@ -552,17 +555,18 @@ class MicromateProtocol:
"refusing to write")
acks = []
for step in plan.steps:
self._parser.reset()
self._pending.clear()
self._send(step.frame, permit=frozenset({step.sub}))
acks.append(self._recv_one(expected_sub=step.ack_sub, reset_parser=False))
acks.append(self._request(step.frame, step.ack_sub,
permit=frozenset({step.sub})))
return acks
def _send(self, frame: bytes, *, permit: frozenset = frozenset()) -> None:
# The gate sees the bytes about to go out, not the caller's intent.
# `permit` is passed only by execute(), for exactly one step.
frame = bytes(frame)
check_transmit(request_sub(frame), self._allowed_writes | permit)
# Trust means the most recent request got a validated Micromate reply.
self.last_flags = None
# The ceiling is enforced here, where frames leave, whatever was permitted.
check_transmit(request_sub(frame), permit & ENABLEABLE_WRITES)
log.debug("TX %d bytes: %s", len(frame), frame.hex())
self._transport.write(frame)
+2 -2
View File
@@ -1,8 +1,8 @@
"""Write plans for a Micromate: the exact frames a write would send, in order.
A plan is what a dry run returns. Building one sends nothing; transmitting it
also needs a protocol constructed with those SUBs in `allowed_writes`, which no
code does yet (see `micromate.opcodes`).
is `MicromateProtocol.execute(plan)` and nothing else: the connection holds no
write permission of its own (see `micromate.opcodes`).
Every input is the unit's OWN read of the block being written (content, i.e.
response data[11:]), and every plan sends back exactly what was read except