fix(micromate): the write ceiling is enforced at the wire; allowed_writes retired; execute takes only real plans
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
1 parent
8daf413fe3
commit
a90b8158b6
5 files changed
+150
-40
No files matched your search
+27
-23
@@ -7,8 +7,8 @@ knows frames, offsets and sequencing, and nothing about what a field means.
|
||||
Scope: **reads only on the wire, enforced** (in this package: the Series-3
|
||||
`minimateplus` stack and raw-socket bench bridges are outside the gate). Every outgoing frame passes
|
||||
`micromate.opcodes.check_transmit()` in `_send`: a write opcode is refused
|
||||
unless this connection was constructed with it in `allowed_writes` (nothing in
|
||||
the codebase does so yet), and `0xA2` -- CONFIRM ERASE on Series III -- is
|
||||
unless it arrives through `execute()` (the connection itself holds no write
|
||||
permission), and `0xA2` -- CONFIRM ERASE on Series III -- is
|
||||
refused always. The gate is an allowlist: a SUB not catalogued in
|
||||
`opcodes` (read or write) is refused as unknown. No command has ever been originated against a unit by this
|
||||
project; every write in ``docs/micromate_protocol_reference.md`` was performed
|
||||
@@ -47,7 +47,7 @@ import logging
|
||||
import math
|
||||
import struct
|
||||
import time
|
||||
from typing import Optional
|
||||
from typing import TYPE_CHECKING, Optional
|
||||
|
||||
from minimateplus.transport import BaseTransport
|
||||
|
||||
@@ -57,6 +57,9 @@ from .framing import (
|
||||
)
|
||||
from .opcodes import ENABLEABLE_WRITES, WRITE_SUBS, OpcodeRefused, check_transmit
|
||||
|
||||
if TYPE_CHECKING:
|
||||
from .writes import WritePlan
|
||||
|
||||
log = logging.getLogger(__name__)
|
||||
|
||||
DEFAULT_RECV_TIMEOUT = 10.0
|
||||
@@ -255,13 +258,9 @@ class MicromateProtocol:
|
||||
transport: BaseTransport,
|
||||
recv_timeout: float = DEFAULT_RECV_TIMEOUT,
|
||||
strict_checksums: bool = True,
|
||||
allowed_writes: frozenset = frozenset(),
|
||||
) -> None:
|
||||
"""
|
||||
Args:
|
||||
allowed_writes: write SUBs this connection may transmit. Empty by
|
||||
default -- every write opcode in `micromate.opcodes` is refused
|
||||
at `_send`, and `0xA2` is refused whatever this says.
|
||||
strict_checksums: raise on a bad checksum. **Defaults to True,
|
||||
unlike the Series III sibling**, which logs and continues
|
||||
because its parser cannot reliably tell an inner-frame
|
||||
@@ -278,13 +277,6 @@ class MicromateProtocol:
|
||||
self._transport = transport
|
||||
self._recv_timeout = recv_timeout
|
||||
self._strict = strict_checksums
|
||||
self._allowed_writes = frozenset(allowed_writes)
|
||||
unknown = self._allowed_writes - set(WRITE_SUBS)
|
||||
if unknown:
|
||||
raise ValueError(
|
||||
"allowed_writes may only name catalogued write SUBs; not in "
|
||||
"micromate.opcodes.WRITE_SUBS: "
|
||||
+ ", ".join(f"0x{x:02X}" for x in sorted(unknown)))
|
||||
self._parser = MicromateFrameParser()
|
||||
self._pending: list[MicromateFrame] = []
|
||||
self.last_flags: Optional[int] = None
|
||||
@@ -526,13 +518,20 @@ class MicromateProtocol:
|
||||
# so anything already buffered when we send is by definition stale, and
|
||||
# `expected_sub` would reject it anyway — better to discard it here than
|
||||
# to raise a confusing UnexpectedResponse one command later.
|
||||
return self._request(build_request(sub, offset, params), 0xFF - sub,
|
||||
timeout=timeout)
|
||||
|
||||
def _request(self, frame: bytes, expected_sub: int, *, timeout: Optional[float] = None,
|
||||
permit: frozenset = frozenset()) -> MicromateFrame:
|
||||
"""Clean slate, send one frame, receive its reply. The one sequence
|
||||
every exchange -- read or execute -- goes through."""
|
||||
self._parser.reset()
|
||||
self._pending.clear()
|
||||
self._send(build_request(sub, offset, params))
|
||||
return self._recv_one(expected_sub=0xFF - sub, timeout=timeout,
|
||||
self._send(frame, permit=permit)
|
||||
return self._recv_one(expected_sub=expected_sub, timeout=timeout,
|
||||
reset_parser=False)
|
||||
|
||||
def execute(self, plan) -> list:
|
||||
def execute(self, plan: "WritePlan") -> list[MicromateFrame]:
|
||||
"""Transmit a `micromate.writes.WritePlan` -- the only write path.
|
||||
|
||||
Permission is granted for this call alone, one step at a time, and only
|
||||
@@ -541,7 +540,11 @@ class MicromateProtocol:
|
||||
is awaited before the next is sent. Never retries: a timeout raises,
|
||||
and what happened is the caller's to find out by reading the unit back.
|
||||
"""
|
||||
beyond = plan.subs - ENABLEABLE_WRITES
|
||||
# Deferred: writes -> setup_block -> protocol would be circular at import.
|
||||
from .writes import WritePlan
|
||||
if not isinstance(plan, WritePlan):
|
||||
raise TypeError(f"execute takes a WritePlan, got {type(plan).__name__}")
|
||||
beyond = {st.sub for st in plan.steps} - ENABLEABLE_WRITES
|
||||
if beyond:
|
||||
raise OpcodeRefused(
|
||||
"plan holds SUB(s) above the write ceiling: "
|
||||
@@ -552,17 +555,18 @@ class MicromateProtocol:
|
||||
"refusing to write")
|
||||
acks = []
|
||||
for step in plan.steps:
|
||||
self._parser.reset()
|
||||
self._pending.clear()
|
||||
self._send(step.frame, permit=frozenset({step.sub}))
|
||||
acks.append(self._recv_one(expected_sub=step.ack_sub, reset_parser=False))
|
||||
acks.append(self._request(step.frame, step.ack_sub,
|
||||
permit=frozenset({step.sub})))
|
||||
return acks
|
||||
|
||||
def _send(self, frame: bytes, *, permit: frozenset = frozenset()) -> None:
|
||||
# The gate sees the bytes about to go out, not the caller's intent.
|
||||
# `permit` is passed only by execute(), for exactly one step.
|
||||
frame = bytes(frame)
|
||||
check_transmit(request_sub(frame), self._allowed_writes | permit)
|
||||
# Trust means the most recent request got a validated Micromate reply.
|
||||
self.last_flags = None
|
||||
# The ceiling is enforced here, where frames leave, whatever was permitted.
|
||||
check_transmit(request_sub(frame), permit & ENABLEABLE_WRITES)
|
||||
log.debug("TX %d bytes: %s", len(frame), frame.hex())
|
||||
self._transport.write(frame)
|
||||
|
||||
|
||||
Reference in new issue
Block a user