fix: rename max_geo_range to ADC scale, and make it so its not user configurable.
fix: change max_geo_range_enum to geo_range with two options (normal and sensitive)
This commit is contained in:
@@ -346,14 +346,14 @@ class ComplianceConfig:
|
||||
# full per-channel data would require structured Channel objects.
|
||||
trigger_level_geo: Optional[float] = None # in/s (first geo channel) ✅
|
||||
alarm_level_geo: Optional[float] = None # in/s (first geo channel) ✅
|
||||
max_range_geo: Optional[float] = None # ADC-to-velocity scale factor (float32 at Tran+28) ✅
|
||||
geo_adc_scale: Optional[float] = None # ADC-to-velocity scale factor (float32 at Tran+28) ✅
|
||||
# = inverse sensitivity = 1/sensitivity (in/s per V)
|
||||
# Formula (Interface Handbook §4.5): Range = 1.61133 V × scale_factor
|
||||
# → 1.61133 × 6.206053 = 10.000 in/s (Normal range) ✅
|
||||
# Firmware uses: PPV (in/s) = ADC_voltage (V) × 6.206053
|
||||
# Identical on BE11529 and BE18189 — same Instantel geophone hardware.
|
||||
# NOT a user-configurable setting. Must NOT be written (use _encode_compliance_config).
|
||||
max_range_geo_enum: Optional[int] = None # max range selector: uint8 at Tran+20
|
||||
# NOT a user-configurable setting. Must NOT be written.
|
||||
geo_range: Optional[int] = None # range selector: uint8 at Tran+20
|
||||
# hypothesis: 0x01 = Normal 10.000 in/s, 0x00 = Sensitive 1.25 in/s
|
||||
# reads 0x01 on all tested units — UNCONFIRMED (need 1.25 in/s capture)
|
||||
|
||||
|
||||
Reference in New Issue