diff --git a/bridges/mm_client_check.py b/bridges/mm_client_check.py index f1e973f..76c7831 100644 --- a/bridges/mm_client_check.py +++ b/bridges/mm_client_check.py @@ -18,9 +18,9 @@ verified that way: than using idle-gap detection, which should be strictly more robust — but "should be" is the point of this script. * **the other firmware line.** `11.0BD` reports `flags = 0x03`, a shorter - model string, and a `SUB 0x1C` block 4 bytes longer. Everything about that - is currently inference from one 2026-09-23 sweep whose captures never - landed in the repo. + model string, and a `SUB 0x1C` block 4 bytes longer. Inferred from a + 2026-09-23 sweep; **confirmed on UM20147 2026-09-30** (forward offsets read + a correct battery and clock). Run it over both paths and diff the two reports. Anything that differs beyond timings is a finding. @@ -244,7 +244,36 @@ def _select(refs, which: str): return [r for r in refs if r.key_hex.lower() == which] -def step(label: str, fn): +def _setup_lines(s) -> list[str]: + """A decoded setup, laid out the way the unit's own menus group it.""" + def sensors(geo: bool, mic: bool) -> str: + return " + ".join(n for n, on in (("geophones", geo), ("mic", mic)) if on) or "none" + + stop = f"Auto, after {s.auto_stop_after_s} s quiet" if s.auto_record_stop else "Fixed" + if s.mic_type == "linear": + mic = f"linear, trigger {s.mic_trigger_db:.1f} dB ({s.mic_trigger_psi:.5f} psi)" + else: + mic = s.mic_type + sd = (f"on: {s.distance_ft:.1f} ft, {s.charge_weight_lb:.1f} lb" + + (f" -> {s.scaled_distance:.2f}" if s.scaled_distance else "") + if s.scaled_distance_enabled else "off") + return [ + f"record mode {s.record_mode_name}", + f"sample rate {s.sample_rate} sps", + f"histogram interval {s.histogram_interval_s} s", + f"record time {s.record_time_s:g} s stop: {stop}", + f"pre-trigger {s.pretrigger_s:g} s", + f"sensors on {sensors(s.geophones_active, s.mic_active)}", + f"trigger on {sensors(s.trigger_on_geophones, s.trigger_on_mic)}", + "geophone trigger " + " / ".join(f"{v:.3f}" for v in s.geo_trigger_ips) + " in/s", + f"microphone {mic}", + f"job number {s.job_number} ({'on' if s.job_number_enabled else 'off'})", + f"scaled distance {sd}", + *(f"note {k:<15}{v!r}" for k, v in s.notes.items()), + ] + + +def step(label: str, fn, show=None): """Run one read, report how long it took and what it returned.""" t0 = time.monotonic() try: @@ -256,6 +285,8 @@ def step(label: str, fn): shown = value if isinstance(value, str) else repr(value) if isinstance(value, list): shown = f"{len(value)} entries" + if show: + shown = show(value) print(f" {label:.<26} {ms:7.0f} ms {shown}") return value @@ -319,9 +350,8 @@ def main() -> int: f"fw={info.firmware_line} monitoring={info.monitoring}") print(f" active setup={info.active_setup!r}") if info.firmware_line == "thor": - print(" *** 11.0BD unit — the FIRST one this code has met. ***") - print(" *** Check the battery and clock below carefully: ***") - print(" *** its 0x1C block is 4 bytes longer. ***") + print(" (11.0BD / Thor line: 0x1C is 4 B longer -- read forward, " + "confirmed 2026-09-30)") state = step("get_state()", mm.get_state) if state: @@ -333,22 +363,30 @@ def main() -> int: print(" *** device clock did not decode — dump raw below. ***") print(f" raw 0x1C content: {_content(state.raw).hex(' ')}") + setup = step("get_setup()", mm.get_setup, show=lambda s: f"{s.name} (checksum ok)") + if setup: + print(" check each line against the unit's screen:") + for line in _setup_lines(setup): + print(f" {line}") + setups = step("list_setups()", mm.list_setups) if setups: print(f" first={setups[0]!r} last={setups[-1]!r}") - # ── SUB 0x06: is content[0:4] really the event count? ───────────── - # Two samples on one unit said yes, and THOR reads it BEFORE the chain - # walk then stops without ever reading the sentinel. A third value - # either confirms it or kills it. + # ── SUB 0x06: event count, and (likely) the monitor-log count ───── + # content[0:4] is the event count: 3/3 against the chain walk, and THOR's + # own ReadEventRecordCount agrees. content[4:8] was once recorded as "a + # constant 9" -- it read 47 during the 10-14 ACH session against THOR's + # "Monitor Log count: 45", so it is very likely the monitor-log count. + # Still graded a strong candidate, not settled (reference, 10-14). claimed = None raw06 = step("0x06 storage range", mm.protocol.read_storage_range) if raw06: c = _content(raw06) claimed = int.from_bytes(c[0:4], "big") - print(f" content[0:4] = {claimed} <- CANDIDATE: event count") + print(f" content[0:4] = {claimed} <- event count") print(f" content[4:8] = {int.from_bytes(c[4:8],'big')} " - f"<- unexplained (read 9 alongside a 6 on UM12947)") + f"<- likely the monitor-log count (strong candidate)") if a.download: print("\n event chain (read-only), via MicromateClient:") diff --git a/micromate/client.py b/micromate/client.py index 98be3ae..1eca521 100644 --- a/micromate/client.py +++ b/micromate/client.py @@ -39,8 +39,9 @@ from typing import Optional from minimateplus.transport import BaseTransport -from .models import MicromateDeviceInfo, MicromateEventRef, MicromateState +from .models import MicromateDeviceInfo, MicromateEventRef, MicromateSetup, MicromateState from .protocol import MicromateProtocol, ProtocolError +from .setup_block import decode_setup log = logging.getLogger(__name__) @@ -300,6 +301,18 @@ class MicromateClient: """`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`.""" return _cstring(_content(self._proto.read_active_setup_name())) + def get_setup(self, *, verify: bool = True) -> MicromateSetup: + """`SUB 0x1A` — what the unit is set to, decoded. One read. + + Raises ``SetupChecksumError`` if the block's CRC fails, unless + ``verify=False``. Offsets and what is deliberately not decoded are in + ``micromate/setup_block.py``. + + ⚠ This reads the keypad's EDIT BUFFER: if someone is in the unit's setup + menu, unsaved values come back. + """ + return decode_setup(_content(self._proto.read_compliance_config()), verify=verify) + def list_setups(self) -> list[str]: """`0x3F` then `0x40`… — every setup file stored on the unit. diff --git a/micromate/models.py b/micromate/models.py index 7b56c2d..68054c7 100644 --- a/micromate/models.py +++ b/micromate/models.py @@ -22,6 +22,7 @@ shrink or disappear. from __future__ import annotations import datetime +import math from dataclasses import dataclass, field from typing import Any, Dict, Optional, Tuple @@ -480,6 +481,81 @@ class MicromateState: return " ".join(bits) +_RECORD_MODES = {0x01: "Waveform", 0x02: "Waveform Manual", 0x03: "Histogram", 0x04: "Histogram Combo"} + +# The unit's OWN conversion constants, identified bit-exactly from what it +# stored for keypad entries (2026-10-19). Not the textbook 3.28084 / 2.20462: +# convert back with these, or 45 lb entered on the unit reads as 44.89 lb. +_FT_PER_M = 3.2808 +_LB_PER_KG = 2.21 +_PA_PER_PSI = 6894.757 +_P_REF_PA = 20e-6 # dB re 20 µPa + + +@dataclass +class MicromateSetup: + """A unit's active setup, from ``SUB 0x1A`` — see ``micromate/setup_block.py``. + + **Measured fields only.** Each was located by changing that one setting on a + unit's keypad and watching the bytes; anything graded inferred or unknown in + the protocol reference is left in ``raw`` rather than guessed at here. + + ⚠ This is what the unit is set to *right now* — including unsaved edits if + someone is in its setup menu, because ``0x1A`` reads the keypad's edit + buffer. Values are in the units the unit stores, whatever it displays: + in/s, psi, metres, kilograms. + """ + + name: str # ⚠ ".MMB" after a keypad save, ".mmb" after a load + record_mode: int # see record_mode_name + sample_rate: int # samples per second + histogram_interval_s: int + pretrigger_s: float # positive; the unit stores it negative + auto_record_stop: bool # False = Fixed record time + record_time_s: float + auto_stop_after_s: int # quiet time before an Auto stop + geophones_active: bool + mic_active: bool + trigger_on_geophones: bool + trigger_on_mic: bool + geo_trigger_ips: Tuple[float, float, float] # Tran, Vert, Long + mic_type: str # "linear" | "sound_level" | "unknown ()" + mic_trigger_psi: Optional[float] # linear mic only; SLM units not measured + job_number_enabled: bool + job_number: int # kept while switched off + scaled_distance_enabled: bool + distance_m: float + charge_weight_kg: float + notes: Dict[str, str] # label -> value, in the unit's order + raw: bytes = field(default=b"", repr=False) # the 2,092-byte content + + @property + def record_mode_name(self) -> str: + return _RECORD_MODES.get(self.record_mode, f"unknown (0x{self.record_mode:02x})") + + @property + def mic_trigger_db(self) -> Optional[float]: + """dB re 20 µPa. Matches the unit's screen to ±0.001 dB on 131 and 140.""" + if not self.mic_trigger_psi: + return None + return 20.0 * math.log10(self.mic_trigger_psi * _PA_PER_PSI / _P_REF_PA) + + @property + def distance_ft(self) -> float: + return self.distance_m * _FT_PER_M + + @property + def charge_weight_lb(self) -> float: + return self.charge_weight_kg * _LB_PER_KG + + @property + def scaled_distance(self) -> Optional[float]: + """ft / √lb, as the unit computes it for display. It is not stored.""" + if self.charge_weight_kg <= 0: + return None + return self.distance_ft / math.sqrt(self.charge_weight_lb) + + @dataclass class MicromateEventRef: """One entry in a unit's event chain, from `1E`/`1F` and optionally `0x0C`. diff --git a/micromate/setup_block.py b/micromate/setup_block.py new file mode 100644 index 0000000..80b3364 --- /dev/null +++ b/micromate/setup_block.py @@ -0,0 +1,154 @@ +""" +setup_block.py — the Micromate setup block (`SUB 0x1A`), decoded. + +Pure byte interpretation: no I/O, no device. `MicromateClient.get_setup()` +does the read and hands the content here. + +Every offset below is into **content** (response data minus its 11-byte prefix) +and was measured on UM20147 (`11.0BD`) by changing one setting on the unit's own +keypad and watching which bytes moved, 2026-10-17/19. Method, grades and the +fields deliberately left out are in docs/micromate_protocol_reference.md, under +*The `0x1A` field map from a keypad pass* and the 2026-10-19 section after it. +""" + +from __future__ import annotations + +import struct + +from .models import MicromateSetup +from .protocol import ProtocolError + + +class SetupChecksumError(ProtocolError): + """A config block's trailing CRC does not match its contents.""" + + +_CRC_POLY = 0x1021 +_CRC_INIT = 0x1D0F # CRC-16/AUG-CCITT +_CONTENT_SIZE = 2092 # = content[0:2] (2090) + the 2-byte CRC + +# ── Head of the block ───────────────────────────────────────────────────────── +_MODE = 5 # 01 Waveform · 02 Manual · 03 Histogram · 04 Combo +_SAMPLE_RATE = slice(6, 8) # uint16 BE ⚠ 4096 puts a literal 0x10 here +_HIST_INTERVAL = slice(8, 10) # uint16 BE seconds +_PRETRIGGER = 12 # f32 BE, NEGATIVE seconds +_STOP_MODE = 17 # 00 Fixed · 01 Auto (u8 or u16 BE [16:18] — unresolved) +_RECORD_TIME = 18 # f32 BE seconds +_AUTO_STOP = 23 # seconds (u8 or u16 BE [22:24] — unresolved) +_SENSORS = 25 # bitmask: 0x07 geophones, 0x08 mic +_TRIGGERS = 29 # same bits: which sensors may trigger +_DISTANCE = 30 # f32 BE metres (keypad: ft / 3.2808) +_CHARGE = 34 # f32 BE kg (keypad: lb / 2.21) +_REPORT_FLAGS = 39 # 0x02 job number on · 0x08 scaled distance on · 0x01 ? +_JOB_NUMBER = slice(40, 42) # uint16 BE +_NAME = slice(42, 86) # setup file name, null-padded + +_GEO_BITS, _MIC_BIT = 0x07, 0x08 +_JOB_ON, _SCALED_ON = 0x02, 0x08 + +# ── Notes: four [label 22][value 42] pairs on a 64-byte stride ──────────────── +_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4 + +# ── Channel blocks, 48 bytes each from content[1708] ────────────────────────── +# 1-3 are the geophones. Block 4 is the ACTIVE mic: a byte copy of block 5 +# (stored linear settings) or block 6 (stored sound-level settings). Read the +# mic from block 4 only — 5 and 6 describe whichever mic is NOT selected. +_CHANNELS, _CHANNEL_SIZE = 1708, 48 +_CH_SENSOR_CODE = slice(4, 8) # uint32 BE: 1 geophone, 2 linear mic, 9 SLM, 0 off +_CH_TRIGGER = 30 # f32 BE: geophone in/s, linear mic psi +_ACTIVE_MIC = 3 # block index (0-based) +_MIC_TYPES = {2: "linear", 9: "sound_level"} + + +def _crc16_aug_ccitt(data: bytes) -> int: + c = _CRC_INIT + for b in data: + c ^= b << 8 + for _ in range(8): + c = ((c << 1) ^ _CRC_POLY) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF + return c + + +def crc_ok(content: bytes) -> bool: + """True if a config block's trailing checksum matches its contents. + + One rule covers the setup (`0x1A`), preferences (`0x08`) and `0x2E` blocks: + ``content[0:2]`` is a uint16 BE length N, and a CRC-16/AUG-CCITT over + ``content[0:N-2]`` is stored big-endian at ``content[N:N+2]``. The two bytes + at ``[N-2:N]`` are zero and not covered. `0x2C` (call-home) has no checksum. + + A block too short to hold its own declared length reads as bad, not as an + error: a truncated read is exactly what this exists to catch. + """ + if len(content) < 2: + return False + n = int.from_bytes(content[0:2], "big") + if n < 2 or len(content) < n + 2: + return False + return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big") + + +def _f32(c: bytes, offset: int) -> float: + return struct.unpack_from(">f", c, offset)[0] + + +def _ascii(buf: bytes) -> str: + return buf.split(b"\x00")[0].decode("ascii", "replace").strip() + + +def _channel(c: bytes, index: int) -> bytes: + start = _CHANNELS + index * _CHANNEL_SIZE + return c[start : start + _CHANNEL_SIZE] + + +def decode_setup(content: bytes, *, verify: bool = True) -> MicromateSetup: + """Decode a setup block's content (``0x1A`` data minus its 11-byte prefix). + + Raises ``SetupChecksumError`` if the trailing CRC does not match — unless + ``verify=False``, which decodes anyway, for looking at what a bad read held. + A block shorter than 2,092 bytes raises ``ProtocolError`` either way: the + checksum is optional, the bounds are not. + """ + if len(content) < _CONTENT_SIZE: + raise ProtocolError(f"setup block content is {len(content)} B, need {_CONTENT_SIZE}") + if verify and not crc_ok(content): + raise SetupChecksumError( + "setup block checksum mismatch — a short or corrupt read " + "(decode_setup(..., verify=False) to inspect it anyway)" + ) + c = content + mic = _channel(c, _ACTIVE_MIC) + mic_code = int.from_bytes(mic[_CH_SENSOR_CODE], "big") + mic_type = _MIC_TYPES.get(mic_code, f"unknown ({mic_code})") + flags = c[_REPORT_FLAGS] + + notes = {} + for n in range(_NOTES): + label = _ascii(c[_NOTE_LABEL + n * _NOTE_STRIDE : _NOTE_VALUE + n * _NOTE_STRIDE]) + value = _ascii(c[_NOTE_VALUE + n * _NOTE_STRIDE : _NOTE_LABEL + (n + 1) * _NOTE_STRIDE]) + notes[label] = value + + return MicromateSetup( + name=_ascii(c[_NAME]), + record_mode=c[_MODE], + sample_rate=int.from_bytes(c[_SAMPLE_RATE], "big"), + histogram_interval_s=int.from_bytes(c[_HIST_INTERVAL], "big"), + pretrigger_s=-_f32(c, _PRETRIGGER), + auto_record_stop=bool(c[_STOP_MODE]), + record_time_s=_f32(c, _RECORD_TIME), + auto_stop_after_s=c[_AUTO_STOP], + geophones_active=bool(c[_SENSORS] & _GEO_BITS), + mic_active=bool(c[_SENSORS] & _MIC_BIT), + trigger_on_geophones=bool(c[_TRIGGERS] & _GEO_BITS), + trigger_on_mic=bool(c[_TRIGGERS] & _MIC_BIT), + geo_trigger_ips=tuple(_f32(_channel(c, i), _CH_TRIGGER) for i in range(3)), + mic_type=mic_type, + mic_trigger_psi=_f32(mic, _CH_TRIGGER) if mic_type == "linear" else None, + job_number_enabled=bool(flags & _JOB_ON), + job_number=int.from_bytes(c[_JOB_NUMBER], "big"), + scaled_distance_enabled=bool(flags & _SCALED_ON), + distance_m=_f32(c, _DISTANCE), + charge_weight_kg=_f32(c, _CHARGE), + notes=notes, + raw=c, + ) diff --git a/scratch/mm_config_diff.py b/scratch/mm_config_diff.py index 20dc294..b96e3da 100644 --- a/scratch/mm_config_diff.py +++ b/scratch/mm_config_diff.py @@ -52,6 +52,7 @@ sys.path.insert(0, str(Path(__file__).resolve().parent.parent)) from bridges.mm_client_check import StdlibSerial # noqa: E402 from micromate.client import MicromateClient # noqa: E402 +from micromate.setup_block import crc_ok # noqa: E402 from minimateplus.transport import TcpTransport # noqa: E402 SNAP_ROOT = Path(__file__).resolve().parent / "mm_config_snaps" @@ -138,28 +139,16 @@ def _interps(a: bytes, b: bytes, off: int, run: int) -> list[str]: return out -def crc16_aug_ccitt(data: bytes) -> int: - """CRC-16/AUG-CCITT: poly 0x1021, init 0x1D0F, no reflection, xorout 0.""" - c = 0x1D0F - for x in data: - c ^= x << 8 - for _ in range(8): - c = ((c << 1) ^ 0x1021) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF - return c +# Blocks that carry the config checksum (micromate.setup_block.crc_ok): N = +# content[0:2], CRC-16/AUG-CCITT over [0:N-2] stored at [N:N+2]. 0x2C has none. +CRC_BLOCKS = {"1A_compliance", "08_event_index", "2E_trigger"} -def crc_status_1a(raw: bytes) -> str: - """Check 0x1A's trailer: CRC over content[0:2088], stored BE at [2090:2092]. - - Found 2026-10-17 from one keypad diff and confirmed on 23 snapshots plus - UM12947's 9-24 capture. A mismatch means a short or corrupt read -- or - that the layout is not what this assumes, which is worth knowing too. - """ +def crc_status(raw: bytes) -> str: + """A mismatch means a short or corrupt read -- or a block this rule misses.""" c = raw[CONTENT:] - if len(c) < 2092: - return f"CRC n/a (content {len(c)} B < 2092)" - want, got = crc16_aug_ccitt(c[:2088]), int.from_bytes(c[2090:2092], "big") - return f"CRC ok ({got:04x})" if want == got else f"CRC MISMATCH computed {want:04x}, stored {got:04x}" + stored = c[int.from_bytes(c[0:2], "big"):][:2].hex() if len(c) >= 2 else "--" + return f"CRC ok ({stored})" if crc_ok(c) else f"CRC MISMATCH (stored {stored})" def _runs(a: bytes, b: bytes, ignore: set[int]) -> list[tuple[int, int]]: @@ -314,8 +303,8 @@ def cmd_watch(mm: MicromateClient, serial: str, interval: float, f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}") for line in _interps(a, b, off, run): print(f" {line}") - if name == "1A_compliance": - print(f" {crc_status_1a(cur[name])}") + if name in CRC_BLOCKS: + print(f" {crc_status(cur[name])}") print(flush=True) prev = cur except KeyboardInterrupt: diff --git a/tests/fixtures/micromate-setup/um12947_2026-09-24.bin b/tests/fixtures/micromate-setup/um12947_2026-09-24.bin new file mode 100644 index 0000000..9602ca7 Binary files /dev/null and b/tests/fixtures/micromate-setup/um12947_2026-09-24.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_4096sps.bin b/tests/fixtures/micromate-setup/um20147_4096sps.bin new file mode 100644 index 0000000..95e8315 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_4096sps.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_baseline.bin b/tests/fixtures/micromate-setup/um20147_baseline.bin new file mode 100644 index 0000000..ec1f28d Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_baseline.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_geo_only.bin b/tests/fixtures/micromate-setup/um20147_geo_only.bin new file mode 100644 index 0000000..81ba8b2 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_geo_only.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_geo_trigger_off.bin b/tests/fixtures/micromate-setup/um20147_geo_trigger_off.bin new file mode 100644 index 0000000..912efcc Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_geo_trigger_off.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_histogram_300s.bin b/tests/fixtures/micromate-setup/um20147_histogram_300s.bin new file mode 100644 index 0000000..47875f7 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_histogram_300s.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_job_1234.bin b/tests/fixtures/micromate-setup/um20147_job_1234.bin new file mode 100644 index 0000000..399ba33 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_job_1234.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_location_bench01.bin b/tests/fixtures/micromate-setup/um20147_location_bench01.bin new file mode 100644 index 0000000..74bf654 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_location_bench01.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_mic_140db.bin b/tests/fixtures/micromate-setup/um20147_mic_140db.bin new file mode 100644 index 0000000..adbd589 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_mic_140db.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_mic_only.bin b/tests/fixtures/micromate-setup/um20147_mic_only.bin new file mode 100644 index 0000000..851d952 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_mic_only.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_pretrig025_auto.bin b/tests/fixtures/micromate-setup/um20147_pretrig025_auto.bin new file mode 100644 index 0000000..4f73dcd Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_pretrig025_auto.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_scaled_distance.bin b/tests/fixtures/micromate-setup/um20147_scaled_distance.bin new file mode 100644 index 0000000..6cc01ae Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_scaled_distance.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_sound_level_mic.bin b/tests/fixtures/micromate-setup/um20147_sound_level_mic.bin new file mode 100644 index 0000000..2518b29 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_sound_level_mic.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_waveform.bin b/tests/fixtures/micromate-setup/um20147_waveform.bin new file mode 100644 index 0000000..87b5a8f Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_waveform.bin differ diff --git a/tests/fixtures/micromate-setup/um20147_waveform_manual.bin b/tests/fixtures/micromate-setup/um20147_waveform_manual.bin new file mode 100644 index 0000000..d31dea2 Binary files /dev/null and b/tests/fixtures/micromate-setup/um20147_waveform_manual.bin differ diff --git a/tests/test_micromate_client.py b/tests/test_micromate_client.py index 2baac1d..b87635d 100644 --- a/tests/test_micromate_client.py +++ b/tests/test_micromate_client.py @@ -22,6 +22,7 @@ sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) from micromate.client import CONTENT, MicromateClient, _content, _cstring from micromate.framing import ETX, STX, checksum, stuff from micromate.protocol import ProtocolError +from micromate.setup_block import SetupChecksumError FLAGS_CB, FLAGS_THOR = 0xC5, 0x03 @@ -491,3 +492,47 @@ def test_the_four_extra_bd_bytes_are_not_all_zero(): """ assert _content(MS_BD_MONITORING)[44:] == bytes.fromhex("0fa00004") assert _content(MS_IDLE)[44:] == b"", "the CB block has no such tail" + + +# ── get_setup() ─────────────────────────────────────────────────────────────── +# Decoding itself is covered field by field in test_micromate_setup.py; these +# check the client's read, its framing round trip and the verify switch. + +SETUP_FIXTURES = os.path.join(os.path.dirname(os.path.abspath(__file__)), "fixtures", "micromate-setup") + + +def _setup_read(name: str) -> bytes: + with open(os.path.join(SETUP_FIXTURES, f"{name}.bin"), "rb") as f: + return f.read() + + +def test_get_setup_is_one_read_of_0x1a(): + """One frame -- not Series III's four-frame compliance sequence.""" + mm, t = client([frame(0xE5, _setup_read("um20147_baseline"))]) + mm.get_setup() + assert [w[5] for w in t.written] == [0x1A] + + +def test_get_setup_survives_a_literal_dle_through_the_framing(): + """4096 sps puts 0x10 in the payload, which the unit must escape on the wire + and the parser must unescape. Wrong either way and the rate reads wrong or + the CRC fails.""" + mm, _ = client([frame(0xE5, _setup_read("um20147_4096sps"))]) + s = mm.get_setup() + assert s.sample_rate == 4096 + assert s.raw == _setup_read("um20147_4096sps")[CONTENT:] + + +def test_get_setup_raises_on_a_corrupt_read_by_default(): + data = bytearray(_setup_read("um20147_baseline")) + data[CONTENT + 5] = 0x05 + mm, _ = client([frame(0xE5, bytes(data))]) + with pytest.raises(SetupChecksumError): + mm.get_setup() + + +def test_get_setup_verify_false_returns_the_corrupt_read(): + data = bytearray(_setup_read("um20147_baseline")) + data[CONTENT + 5] = 0x05 + mm, _ = client([frame(0xE5, bytes(data))]) + assert mm.get_setup(verify=False).record_mode == 0x05 diff --git a/tests/test_micromate_setup.py b/tests/test_micromate_setup.py new file mode 100644 index 0000000..39d7130 --- /dev/null +++ b/tests/test_micromate_setup.py @@ -0,0 +1,272 @@ +""" +Tests for micromate/setup_block.py — the Micromate setup block (SUB 0x1A) decoder. + +Every fixture is a real read off a unit, taken with scratch/mm_config_diff.py +while an operator changed settings on the unit's own keypad, 2026-10-17/19. +**Expected values are what the operator read off the unit's screen**, recorded in +docs/micromate_protocol_reference.md — never values computed by this decoder. +A test whose expectation came from the code under test passes whatever the code +does. + +Fixtures are 2,103-byte `0x1A` response data: an 11-byte prefix, then the +2,092-byte content the decoder reads. `um12947_2026-09-24.bin` is a second unit +on the other firmware line, cut from Thor's 9-24 "send TEST1" capture. +""" + +from __future__ import annotations + +import os +import sys +from pathlib import Path + +import pytest + +sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) + +from micromate.protocol import ProtocolError # noqa: E402 +from micromate.setup_block import SetupChecksumError, crc_ok, decode_setup # noqa: E402 + +FIXTURES = Path(__file__).parent / "fixtures" / "micromate-setup" +ALL_FIXTURES = sorted(FIXTURES.glob("*.bin")) + +# Small real blocks for the generic checksum rule (content only, prefix stripped). +# 0x08 preferences, Imperial and Metric -- UM20147, 2026-10-19 17:07 / 17:14. +PREFS_IMPERIAL = bytes.fromhex( + "00580900000000000000000000000000000000000000000000000000000000000000000000" + "000000000100010001000100000000000000010001000000000000000000000000000000" + "000002000000000000000200000000b42f" +) +PREFS_METRIC = bytes.fromhex( + "00580900000000000000000000000000000000000000000000000000000000010000000000" + "000000000100010001000100000000000000010001000000000000000000000000000000" + "000002000000000000000200000000911a" +) +# 0x2E, same session. +BLOCK_2E = bytes.fromhex("001ad50000010000000000000000000000000000000000000000141a") + + +def content_of(name: str) -> bytes: + return (FIXTURES / f"{name}.bin").read_bytes()[11:] + + +# ── The checksum rule ───────────────────────────────────────────────────────── + +def test_fixtures_are_present(): + """15 fixtures; a missing directory would otherwise make the parametrised + tests below collect nothing and pass vacuously.""" + assert len(ALL_FIXTURES) == 15 + + +@pytest.mark.parametrize("path", ALL_FIXTURES, ids=lambda p: p.stem) +def test_every_real_setup_read_passes_its_checksum(path): + assert crc_ok(path.read_bytes()[11:]) + + +@pytest.mark.parametrize( + "block", [PREFS_IMPERIAL, PREFS_METRIC, BLOCK_2E], ids=["0x08-imperial", "0x08-metric", "0x2E"] +) +def test_the_rule_is_the_blocks_own_length_not_the_setup_size(block): + """One rule covers three blocks: N = content[0:2], CRC over [0:N-2] stored at + [N:N+2]. An implementation hard-wired to the setup block's 2088 fails here.""" + assert crc_ok(block) + + +@pytest.mark.parametrize("offset", [5, 144, 1738, 2087], ids=["mode", "note", "trigger", "last-covered"]) +def test_one_changed_byte_fails_the_checksum(offset): + c = bytearray(content_of("um20147_baseline")) + c[offset] ^= 0x01 + assert not crc_ok(bytes(c)) + + +def test_a_changed_trailer_fails_the_checksum(): + c = bytearray(content_of("um20147_baseline")) + c[2091] ^= 0x01 + assert not crc_ok(bytes(c)) + + +@pytest.mark.parametrize("n", [0, 1, 2, 100, 2091], ids=lambda n: f"{n}B") +def test_a_block_too_short_for_its_own_length_fails(n): + """A truncated read must read as bad, never raise IndexError and never pass.""" + assert not crc_ok(content_of("um20147_baseline")[:n]) + + +# ── Fields: every value below is what the operator read off the screen ──────── + +@pytest.mark.parametrize( + "name, mode_code, mode_name", + [ + ("um20147_waveform", 0x01, "Waveform"), + ("um20147_waveform_manual", 0x02, "Waveform Manual"), + ("um20147_histogram_300s", 0x03, "Histogram"), + ("um20147_baseline", 0x04, "Histogram Combo"), + ], +) +def test_record_mode(name, mode_code, mode_name): + """Same codes as Series III, one byte later than the S3 analogy put them. + The keypad menu order is 03 04 01 02, so an off-by-one enum reads wrong here.""" + s = decode_setup(content_of(name)) + assert s.record_mode == mode_code + assert s.record_mode_name == mode_name + + +@pytest.mark.parametrize( + "name, rate", + [("um20147_baseline", 1024), ("um20147_waveform_manual", 2048), ("um20147_4096sps", 4096)], +) +def test_sample_rate(name, rate): + """4096 puts a literal 0x10 (DLE) at content[6] -- the case that shifted + every later field by one byte on Series III.""" + assert decode_setup(content_of(name)).sample_rate == rate + + +@pytest.mark.parametrize("name, seconds", [("um20147_baseline", 2), ("um20147_histogram_300s", 300)]) +def test_histogram_interval(name, seconds): + """300 = 01 2c: the high byte is what proves the field is two bytes wide.""" + assert decode_setup(content_of(name)).histogram_interval_s == seconds + + +@pytest.mark.parametrize("name, seconds", [("um20147_baseline", 1.0), ("um20147_pretrig025_auto", 0.25)]) +def test_pretrigger_is_reported_positive(name, seconds): + """Stored as NEGATIVE seconds (-1.0 / -0.25); the screen shows 1.0 / 0.25.""" + assert decode_setup(content_of(name)).pretrigger_s == seconds + + +@pytest.mark.parametrize( + "name, auto, record_time, auto_stop", + [("um20147_baseline", False, 10.0, 3), ("um20147_pretrig025_auto", True, 11.0, 1)], +) +def test_record_time_window(name, auto, record_time, auto_stop): + s = decode_setup(content_of(name)) + assert s.auto_record_stop is auto + assert s.record_time_s == record_time + assert s.auto_stop_after_s == auto_stop + + +@pytest.mark.parametrize( + "name, geo_on, mic_on, trig_geo, trig_mic", + [ + ("um20147_baseline", True, True, True, True), + ("um20147_geo_only", True, False, True, False), + ("um20147_mic_only", False, True, False, True), + ("um20147_geo_trigger_off", True, True, False, True), + ], +) +def test_active_sensors_and_trigger_sources_are_separate_masks(name, geo_on, mic_on, trig_geo, trig_mic): + """content[25] is which sensors are on, content[29] which may trigger. + geo_trigger_off has both sensors on but only the mic triggering -- a decoder + reading both from one byte gets that fixture wrong.""" + s = decode_setup(content_of(name)) + assert (s.geophones_active, s.mic_active) == (geo_on, mic_on) + assert (s.trigger_on_geophones, s.trigger_on_mic) == (trig_geo, trig_mic) + + +@pytest.mark.parametrize( + "name, level", + [("um20147_baseline", 0.5), ("um20147_waveform_manual", 0.6), ("um12947_2026-09-24", 0.3)], +) +def test_geophone_trigger_level_per_channel(name, level): + s = decode_setup(content_of(name)) + assert s.geo_trigger_ips == pytest.approx((level, level, level), abs=1e-6) + + +@pytest.mark.parametrize("name, db", [("um20147_baseline", 131.0), ("um20147_mic_140db", 140.0)]) +def test_linear_mic_trigger_is_psi_and_reads_back_as_the_screens_db(name, db): + s = decode_setup(content_of(name)) + assert s.mic_type == "linear" + assert s.mic_trigger_psi is not None + assert s.mic_trigger_db == pytest.approx(db, abs=0.01) + + +def test_the_mic_comes_from_block_4_not_from_the_stored_setups(): + """Block 4 is the ACTIVE mic; blocks 5/6 are stored linear/SLM settings. + With a sound-level mic selected, block 5 still holds a linear mic -- read it + and the decoder reports a mic that is not plugged in.""" + s = decode_setup(content_of("um20147_sound_level_mic")) + assert s.mic_type == "sound_level" + assert s.mic_trigger_psi is None # its unit is not measured; not exposed + assert s.mic_trigger_db is None + + +@pytest.mark.parametrize( + "name, enabled, number", + [ + ("um20147_baseline", False, 0), + ("um20147_job_1234", True, 1234), + ("um20147_scaled_distance", False, 1234), # switched off, number kept + ], +) +def test_job_number(name, enabled, number): + s = decode_setup(content_of(name)) + assert s.job_number_enabled is enabled + assert s.job_number == number + + +def test_scaled_distance_uses_the_units_own_conversion_constants(): + """Entered as 123 ft and 45 lb; the screen then showed scaled distance 18.34. + Stored as metres and kg via ft / 3.2808 and lb / 2.21 -- converting back with + the textbook 2.20462 shows 44.89 lb, not what the operator typed.""" + s = decode_setup(content_of("um20147_scaled_distance")) + assert s.scaled_distance_enabled is True + assert s.distance_ft == pytest.approx(123.0, abs=1e-3) + assert s.charge_weight_lb == pytest.approx(45.0, abs=1e-3) + assert s.scaled_distance == pytest.approx(18.34, abs=0.005) + + +def test_scaled_distance_off_with_no_charge_weight(): + s = decode_setup(content_of("um20147_baseline")) + assert s.scaled_distance_enabled is False + assert s.scaled_distance is None # no charge weight: nothing to divide by + + +def test_notes_are_label_value_pairs(): + s = decode_setup(content_of("um20147_location_bench01")) + assert list(s.notes) == ["Location", "Client", "Company", "General Notes"] + assert s.notes["Location"] == "BENCH01" + + +def test_a_second_unit_on_the_other_firmware_line(): + """UM12947 (11.0CB), cut from Thor's 9-24 capture: a different unit, firmware + and setup. Strings are this job's notes as the read returned them.""" + s = decode_setup(content_of("um12947_2026-09-24")) + assert s.name == "Univ of Pitt-1st Yr. Housing-Loc1 Ruskin.mmb" + assert s.notes == { + "Location": "Univ of Pitt-1st Yr Housing-Loc1 Ruskin", + "Client": "PJ Dick Inc.", + "Company": "Terra-Mechanics, Inc. - Harrison", + "General Notes": "Loc#1-Univ of Pitt. - Ruskin Hall", + } + + +def test_raw_is_the_content(): + c = content_of("um20147_baseline") + assert decode_setup(c).raw == c + + +# ── Errors ──────────────────────────────────────────────────────────────────── + +def test_a_corrupt_block_raises_rather_than_decoding_garbage(): + c = bytearray(content_of("um20147_baseline")) + c[5] = 0x05 # a mode byte no keypad produces + with pytest.raises(SetupChecksumError): + decode_setup(bytes(c)) + + +def test_a_checksum_error_is_a_protocol_error(): + """Callers already catching ProtocolError around a read keep working.""" + assert issubclass(SetupChecksumError, ProtocolError) + + +def test_verify_false_decodes_a_corrupt_block_anyway(): + """For diagnosis: see what a bad read contained instead of only that it was bad.""" + c = bytearray(content_of("um20147_baseline")) + c[5] = 0x05 + s = decode_setup(bytes(c), verify=False) + assert s.record_mode_name == "unknown (0x05)" + + +@pytest.mark.parametrize("verify", [True, False]) +def test_a_short_block_raises_even_without_verify(verify): + """verify=False skips the checksum, never the bounds -- a short read would + otherwise decode as zeros, or raise an IndexError from deep in a slice.""" + with pytest.raises(ProtocolError, match="2092"): + decode_setup(content_of("um20147_baseline")[:1900], verify=verify)