docs: roadmap entry for sensor-check waveform extraction

BW's Event Report PDFs include a per-channel sensor-check response
waveform on the right side of the bottom plot (damped sinusoid for
geo channels, sawtooth-at-test-freq for mic).  Looks like real
per-sample data extracted from the binary, not synthesized.

Our parser captures the test results (freq, ratio, amplitude,
pass/fail) but not the waveform samples — so the report shows text
only for sensor check.  Pinning a roadmap entry to investigate the
binary for the sample data (path a) or fall back to synthesized
visualization (path b).

Current text-only display is operationally sufficient.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
2026-05-28 04:17:50 +00:00
parent 87aec3f4d1
commit b59f886cb7
+1
View File
@@ -567,3 +567,4 @@ Implementation steps (concrete):
- [ ] RV55 DCD/DTR — newer RV55 firmware doesn't assert DCD by default; units don't resume monitoring after call-home disconnect (`--restart-monitoring` flag deferred). - [ ] RV55 DCD/DTR — newer RV55 firmware doesn't assert DCD by default; units don't resume monitoring after call-home disconnect (`--restart-monitoring` flag deferred).
- [ ] **NULL-timestamp duplicate-row dedup.** A small handful of events (2 known on prod as of 2026-05-22) have `events.timestamp IS NULL` because the codec couldn't extract a timestamp from the binary footer. The `UNIQUE(serial, timestamp)` constraint doesn't fire on `NULL` (SQL semantics: `NULL ≠ NULL`), so every `--force` backfill INSERTs a new row instead of UPSERTing the existing one. Cleanup: a one-shot SQL query that keeps only the newest row per `(serial, blastware_filename)` and deletes the rest. Longer-term: extend the unique key to `(serial, COALESCE(timestamp, blastware_filename))` or reject inserts with NULL timestamp. - [ ] **NULL-timestamp duplicate-row dedup.** A small handful of events (2 known on prod as of 2026-05-22) have `events.timestamp IS NULL` because the codec couldn't extract a timestamp from the binary footer. The `UNIQUE(serial, timestamp)` constraint doesn't fire on `NULL` (SQL semantics: `NULL ≠ NULL`), so every `--force` backfill INSERTs a new row instead of UPSERTing the existing one. Cleanup: a one-shot SQL query that keeps only the newest row per `(serial, blastware_filename)` and deletes the rest. Longer-term: extend the unique key to `(serial, COALESCE(timestamp, blastware_filename))` or reject inserts with NULL timestamp.
- [ ] **Histogram body sub-format with `byte[5] != 0`.** ~3 events on prod (`T190LD5Q.LD0H`, `O121L4L1.GU0H`) use a histogram body my walker doesn't recognize — the first block has `byte[5] = 0x01` or `0x07` instead of `0x00`, and the entire body lacks the `1e 0a 00 00` tail signature. Codec returns 0 valid blocks; their DB PVS comes from the bw_report ASCII overlay (which BW computed from the same binary, so the DB columns are correct). Only the `.h5` waveform plot is empty. Cracking the sub-format would unlock the plot. Needs binary+ASCII pairs from a few `byte[5]!=0` events; same RE approach as the K558 case. - [ ] **Histogram body sub-format with `byte[5] != 0`.** ~3 events on prod (`T190LD5Q.LD0H`, `O121L4L1.GU0H`) use a histogram body my walker doesn't recognize — the first block has `byte[5] = 0x01` or `0x07` instead of `0x00`, and the entire body lacks the `1e 0a 00 00` tail signature. Codec returns 0 valid blocks; their DB PVS comes from the bw_report ASCII overlay (which BW computed from the same binary, so the DB columns are correct). Only the `.h5` waveform plot is empty. Cracking the sub-format would unlock the plot. Needs binary+ASCII pairs from a few `byte[5]!=0` events; same RE approach as the K558 case.
- [ ] **Sensor-check waveform extraction from the BW binary.** BW's Event Report PDFs include a narrow panel on the right side of the waveform plot showing each channel's response to the sensor self-check signal (a damped sinusoid for geo, sawtooth-at-test-freq for mic). Our parser captures the test RESULTS (`test_freq_hz`, `test_ratio`, `test_amplitude_mv`, `test_results` pass/fail) and the PDF + modal display them as text — but BW's per-sample sensor-check waveform isn't accessible to us today. Two paths to add it: (a) RE the binary to find where the sensor-check samples are stored — could be a section before STRT, after the footer, or in a separate sub-record; protocol reference doesn't currently mention it. (b) If samples aren't in the binary, synthesize a representative waveform from the test parameters (damped sinusoid at `test_freq_hz` with damping from `test_ratio`). Path (a) is the honest answer; path (b) is decorative. Until either lands, the text-only sensor-check display in the report is fine.