feat: implement geophone sensitivity and recording mode settings in compliance config
This commit is contained in:
@@ -105,6 +105,7 @@
|
||||
| 2026-04-11 | §14.6 | **RESOLVED — ACH Session Lifecycle is no longer "Future".** `bridges/ach_server.py` fully implements inbound ACH: POLL handshake, device info, event download. State tracked via `ach_state.json` (key-based, with `max_downloaded_key` for post-erase detection). `--clear-after-download` flag added for the standard delete-after-upload workflow. |
|
||||
| 2026-04-17 | §7.6.2, §14 | **RESOLVED — Float 6.206053 at channel_label+28 is the ADC-to-velocity scale factor.** Confirmed from Series III Interface Handbook §4.5 formula: `Range (×1) = 1.61133 V / Sensitivity (V/unit)`. For the standard Instantel geophone at Normal range (10.000 in/s): Sensitivity = 1.61133 / 10 = 0.161133 V/(in/s). The stored value is the **inverse sensitivity** = 1/0.161133 = **6.206053 (in/s)/V**. Cross-check: 1.61133 V × 6.206053 = 10.000 in/s ✅. The firmware uses it as: `PPV (in/s) = ADC_voltage (V) × 6.206053`. Value is identical on all Instantel standard geophones — it is a hardware/firmware constant, NOT a user-configurable setting. Do NOT write this field. Open question §14 item "Max Geo Range float 6.2061" is now **RESOLVED**. |
|
||||
| 2026-04-20 | §7.6.4 (NEW), §7.9, Appendix B | **CONFIRMED — Recording Mode byte location.** Three targeted captures (4-20-26) confirmed `recording_mode` at **`cfg[5]`** in the SUB 71 write payload (3-chunk compliance write). Method: single Blastware session, one initial E5 config pull, then three sequential "Send to unit" writes changing Recording Mode only. Diff of SUB 71 chunk-1 payloads: only `cfg[5]` and `cfg[1024]` changed; `cfg[1024]` delta exactly equals `cfg[5]` delta (chunk running checksum). In the E5 read response (sub-frame 1, page=0x0010), the field is at **`data[17]`** (= **anchor − 4** from the 10-byte anchor), one position earlier than in the write payload due to an extra `0x10` byte at `data[18]` present only in the read format. Enum: `0x00`=Single Shot, `0x01`=Continuous, `0x03`=Histogram, `0x04`=Histogram+Continuous. `0x02` value not yet observed. See §7.6.4 for full details. |
|
||||
| 2026-04-20 | §7.6.2, §7.9, Appendix B | **CONFIRMED — Geophone maximum range / sensitivity selector byte location.** Two targeted captures (4-20-26, geo sensitivity folder): one at Normal 10.000 in/s, one at Sensitive 1.250 in/s. E5 read payload diff: exactly 3 bytes differ at channel_label+33 for Tran/Vert/Long. Values: `0x00`=Normal 10.000 in/s, `0x01`=Sensitive 1.250 in/s. Same offset applies to the SUB 71 write payload (which is the same 2126-byte E5-format buffer round-tripped verbatim). **`channel_label+20` reads `0x01` in ALL captures regardless of range setting — it is NOT this field.** Previous hypothesis (uint8 at Tran+20, 0x01=Normal) was WRONG. Stored as `geo_range` in `ComplianceConfig`. Encoded to all three geo channel blocks (Tran/Vert/Long) at label+33. |
|
||||
|
||||
---
|
||||
|
||||
@@ -1322,8 +1323,8 @@ Fields visible in the Blastware "Compliance Setup" dialog. ✅ = byte offset co
|
||||
| Geophone — Enable all | bool | ❓ |
|
||||
| Geophone — Trigger Source | bool | ❓ |
|
||||
| Chan 1-3 Trigger Level | float, in/s | ✅ `trigger_level_geo` |
|
||||
| Chan 1-3 Maximum Range (range selector enum) | Normal 10.000 / 1.25 in/s | ❓ `max_range_geo_enum` — uint8 at Tran+20; reads `0x01` on both tested units (Normal range); hypothesis `0x01`=Normal, `0x00`=Sensitive — UNCONFIRMED, need 1.25 in/s capture |
|
||||
| Chan 1-3 ADC Scale Factor | 6.206053 (in/s)/V | ✅ `max_range_geo` at Tran+28 — **CONFIRMED 2026-04-17.** Inverse sensitivity = 1/0.161133. Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s. Hardware constant — do NOT write. |
|
||||
| Chan 1-3 Maximum Range (range selector) | Normal 10.000 / 1.25 in/s | ✅ `geo_range` uint8 — **CONFIRMED 2026-04-20.** Offset = Tran+33 (same in E5 read and SUB 71 write — 2126-byte buffer is round-tripped verbatim). `0x00`=Normal 10 in/s, `0x01`=Sensitive 1.25 in/s. Applied to Tran/Vert/Long. **`Tran+20` is NOT this field** (constant 0x01 on all captures). |
|
||||
| Chan 1-3 ADC Scale Factor | 6.206053 (in/s)/V | ✅ `geo_adc_scale` float32 — **CONFIRMED 2026-04-17.** Offset = Tran+28 (same in E5 read and SUB 71 write). Inverse sensitivity = 1/0.161133. Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s. Hardware constant — do NOT write. |
|
||||
| Microphone — Enable all | bool | ❓ |
|
||||
| Microphone — Trigger Source | bool | ❓ |
|
||||
| Chan 4 Trigger Level | float, dB or psi | ❓ |
|
||||
@@ -2018,8 +2019,8 @@ The `.bin` files produced by `s3_bridge` are **not raw wire bytes**. The logger
|
||||
| Trigger Level (Mic) | §3.8.6 | Channel block, float | float32 BE | 100–148 dB in 1 dB steps |
|
||||
| Alarm Level (Mic) | §3.9.10 | Channel block, float | float32 BE | higher than mic trigger |
|
||||
| Record Time | §3.8.9 | cfg anchor+10, float32 BE (wire); `.set` +16, uint32 LE (file) | float32 BE (wire) | 1–105 s; confirmed 3→`40400000`, 5→`40A00000`, 8→`41000000`, 13→`41500000`. Use anchor §7.6.1/§7.6.3 — NOT fixed offset. |
|
||||
| ADC Scale Factor (max_range_geo) | §3.8.4 / Interface Handbook §4.5 | Channel block, Tran+28, float32 BE | float32 BE = 6.206053 | ✅ CONFIRMED 2026-04-17 — inverse sensitivity (in/s)/V. `Range = 1.61133 V × 6.206053 = 10.000 in/s`. Firmware: `PPV (in/s) = ADC_voltage × 6.206053`. Hardware constant, identical on all units. Do NOT write. |
|
||||
| Max Geo Range Enum (max_range_geo_enum) | §3.8.4 | Channel block, Tran+20, uint8 | uint8 | ❓ UNCONFIRMED — reads `0x01` on both tested units (Normal range). Hypothesis: `0x01`=Normal (Gain=1, 10 in/s), `0x00`=Sensitive (Gain=8, 1.25 in/s). Need 1.25 in/s capture to verify. |
|
||||
| ADC Scale Factor (geo_adc_scale) | §3.8.4 / Interface Handbook §4.5 | Channel block, Tran+28 (same in E5 read and SUB 71 write), float32 BE | float32 BE = 6.206053 | ✅ CONFIRMED 2026-04-17 — inverse sensitivity (in/s)/V. `Range = 1.61133 V × 6.206053 = 10.000 in/s`. Firmware: `PPV (in/s) = ADC_voltage × 6.206053`. Hardware constant, identical on all units. Do NOT write. |
|
||||
| Max Geo Range (geo_range) | §3.8.4 | Channel block, Tran+33 (same in E5 read and SUB 71 write), uint8; applied to Tran/Vert/Long | uint8 | ✅ CONFIRMED 2026-04-20 — `0x00`=Normal 10.000 in/s, `0x01`=Sensitive 1.250 in/s. **NOTE: `Tran+20` reads `0x01` on ALL captures regardless of range — it is NOT this field.** |
|
||||
| Microphone Units | §3.9.7 | Inline unit string | char[4] | `"psi\0"`, `"pa.\0"`, `"dB\0\0"` |
|
||||
| Sample Rate | §3.8.2 | cfg anchor−2, uint16 BE — anchor=`\x01\x2c\x00\x00\xbe\x80\x00\x00\x00\x00` in cfg[40:100] | uint16 BE | Normal=1024, Fast=2048, Faster=4096 ✅ CONFIRMED 2026-04-01 (BE11529 S338.17). Anchor required — see §7.6.3 DLE jitter. |
|
||||
| Record Mode | §3.8.1 | Write: `cfg[anchor−3]`, uint8. Read (E5 sf1): `data[anchor−4]`, uint8. Note: extra `0x10` byte at read `data[anchor−3]` shifts offset by 1 vs write. | uint8 | `0x00`=Single Shot, `0x01`=Continuous, `0x02`=unknown, `0x03`=Histogram, `0x04`=Histogram+Continuous. ✅ CONFIRMED 2026-04-20 |
|
||||
|
||||
Reference in New Issue