feat: implement geophone sensitivity and recording mode settings in compliance config
This commit is contained in:
@@ -361,9 +361,11 @@ class ComplianceConfig:
|
||||
# Firmware uses: PPV (in/s) = ADC_voltage (V) × 6.206053
|
||||
# Identical on BE11529 and BE18189 — same Instantel geophone hardware.
|
||||
# NOT a user-configurable setting. Must NOT be written.
|
||||
geo_range: Optional[int] = None # range selector: uint8 at Tran+20
|
||||
# hypothesis: 0x01 = Normal 10.000 in/s, 0x00 = Sensitive 1.25 in/s
|
||||
# reads 0x01 on all tested units — UNCONFIRMED (need 1.25 in/s capture)
|
||||
geo_range: Optional[int] = None # range/sensitivity selector — CONFIRMED 2026-04-20
|
||||
# 0x00 = Normal 10.000 in/s (standard gain)
|
||||
# 0x01 = Sensitive 1.250 in/s (high gain)
|
||||
# Offset: Tran+33 in both E5 read and SUB 71 write payloads
|
||||
# (same 2126-byte buffer is round-tripped; applied to Tran/Vert/Long)
|
||||
|
||||
# Project/setup strings (sourced from E5 / SUB 71 write payload)
|
||||
# These are the FULL project metadata from compliance config,
|
||||
|
||||
Reference in New Issue