feat(sfm): start/stop monitoring by serial -- dry run, audit, read-back

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-23 16:57:47 -04:00
1 parent ce5d2cb0d6
commit c3e7e169c0
2 files changed
+180 -6

No files matched your search

+54 -5
View File
@@ -87,6 +87,7 @@ import dataclasses
from sfm.device_access import DeviceAccess, DeviceError, UnitAddress
from sfm.device_access.errors import BadRequest
from sfm.device_access.series import normalise_serial
from sfm.audit import DbAudit
logging.basicConfig(
level=logging.INFO,
@@ -359,7 +360,8 @@ def _run_with_retry(fn, *, is_tcp: bool):
# legacy Series-3 path unchanged (spec 2026-10-20).
# Constructing it does no I/O and starts no thread until a Series-4 session exists.
_device_access_instance: DeviceAccess = DeviceAccess()
# The audit sink is mandatory for live changes: without one they are refused.
_device_access_instance: DeviceAccess = DeviceAccess(audit=DbAudit(_get_db))
def _device_access() -> DeviceAccess:
@@ -380,9 +382,22 @@ def _via_device_access(fn) -> dict:
return dataclasses.asdict(result) if dataclasses.is_dataclass(result) else result
def _change_response(fn) -> JSONResponse:
"""Run a start/stop; the ChangeResult is the body, its outcome picks the status.
DeviceError mapping is _via_device_access's -- not repeated here.
"""
body = _via_device_access(fn)
status = 200
if body["outcome"] == "failed":
status = 409 if body["verified"] == "mismatch" else 502
return JSONResponse(status_code=status, content=body)
_SERIAL_AWARE_PATHS = frozenset({
"/device/info", "/device/connect", "/device/monitor/status", "/device/settings",
"/device/events", "/device/events/download",
"/device/monitor/start", "/device/monitor/stop",
})
@@ -1838,15 +1853,32 @@ def device_rescue(
@app.post("/device/monitor/start")
def device_monitor_start(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
dry_run: bool = Query(False, description="Return the planned frames; send nothing"),
even_if_already: bool = Query(False, description="Send even if the unit is already in the target state"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""
Command the device to start monitoring (recording triggered events).
Sends SUB 0x96 and waits for ack SUB 0x69.
With `serial`: the unit's identity is read first (a different unit is a 409,
nothing sent), then its state; `dry_run` returns the planned frames and sends
nothing; a live change is audited, verified by reading the state back, and
never retried. The response is the ChangeResult (409 if the unit never
reached the state, 502 if the ack was lost).
Without `serial`: the legacy behaviour above, unchanged.
"""
if serial:
return _change_response(lambda: _device_access().start_monitoring(
_unit_address(port, baud, host, tcp_port), serial, dry_run=dry_run,
even_if_already=even_if_already, caller=caller or "api"))
baud = 38400 if baud is None else baud
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
with _build_client(port=port, baud=baud, host=host, tcp_port=tcp_port) as client:
try:
@@ -1864,15 +1896,32 @@ def device_monitor_start(
@app.post("/device/monitor/stop")
def device_monitor_stop(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
dry_run: bool = Query(False, description="Return the planned frames; send nothing"),
even_if_already: bool = Query(False, description="Send even if the unit is already in the target state"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""
Command the device to stop monitoring.
Sends SUB 0x97 and waits for ack SUB 0x68.
With `serial`: the unit's identity is read first (a different unit is a 409,
nothing sent), then its state; `dry_run` returns the planned frames and sends
nothing; a live change is audited, verified by reading the state back, and
never retried. The response is the ChangeResult (409 if the unit never
reached the state, 502 if the ack was lost).
Without `serial`: the legacy behaviour above, unchanged.
"""
if serial:
return _change_response(lambda: _device_access().stop_monitoring(
_unit_address(port, baud, host, tcp_port), serial, dry_run=dry_run,
even_if_already=even_if_already, caller=caller or "api"))
baud = 38400 if baud is None else baud
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
with _build_client(port=port, baud=baud, host=host, tcp_port=tcp_port) as client: