fix: bench follow-ups -- the setup-menu warning, observed call-home values, waveform read

From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
  the unit's setup menu: a write sent with the menu open was acknowledged
  and read back, then lost on Cancel or Save -- the menu writes its own
  copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
  the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
  took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
  settings read does (it failed closed: the write's block check refused
  203 bytes).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-04 16:15:28 -05:00
1 parent 55c7b7b5ae
commit c790e20116
6 files changed
+68 -10

No files matched your search

+9 -6
View File
@@ -22,6 +22,7 @@ from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
from .setup_block import crc_ok
_CONFIRM = 0xFFFF
_CALL_HOME_OBSERVED = (0x00, 0x01, 0x04, 0x05) # content[5] values units have held
# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
@@ -113,9 +114,10 @@ def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
Bit 0 of `[5]` is the enable. 🔶 UM12947 (THOR's unit) read 0x05 enabled /
0x04 disabled, bit 2 set in both; UM20147 reads 0x01 (measured, phase-2 dry
run). So on UM20147 "off" writes 0x00, a value no capture shows being
written: the target value there is unobserved, and the plan's `warnings`
say so. `[118:120]` is unit-maintained and THOR echoes it.
run). So on UM20147 "off" writes 0x00 -- measured at the bench 2026-11-03
(and again 11-04): 0x01 <-> 0x00 acknowledged, read back, and matched in the
unit's own menu. A value outside those four still carries a warning.
`[118:120]` is unit-maintained and THOR echoes it.
"""
if len(call_home) != _CALL_HOME_LEN:
raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
@@ -128,9 +130,10 @@ def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
what = "call-home " + ("enable" if enabled else "disable")
start = call_home[5]
warnings = []
if start not in (0x04, 0x05) or b5 not in (0x04, 0x05):
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: THOR was only ever "
"seen writing 0x04/0x05 (UM12947); this value is unobserved")
if start not in _CALL_HOME_OBSERVED or b5 not in _CALL_HOME_OBSERVED:
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: no unit has been seen "
"holding this value (0x04/0x05 UM12947 by THOR, 0x00/0x01 UM20147 "
"by SFM); it is unobserved")
if b5 == start:
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
" -- this write changes nothing")