chore(release): v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone

- CHANGELOG: Unreleased -> v0.34.0 — 2026-11-04, with the release theme
  and a Migration section (schema re-key + overnight backfill that moves
  every Series-3 histogram time by one second; rehearsed twice on a copy
  of prod's 2026-09-30 snapshot).
- pyproject.toml, CLAUDE.md, README: 0.34.0 (README gains its status
  entry).
- TOOL_VERSION 0.34.0: the codec changed, so the backfill regenerates.

Verified on dev before this commit: the full decode checker matches
pre-parity dev on every verdict of all 70,112 DL2 events (47 of 88
fields), group D part 1 ran clean on its branch, and the suite has only
the 16 known failures (1,566 passed).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-04 17:58:54 -05:00
1 parent 9f3434ff2b
commit c9f41deadd
5 files changed
+107 -5

No files matched your search

+20 -1
View File
@@ -1,4 +1,4 @@
# seismo-relay `v0.33.0`
# seismo-relay `v0.34.0`
A ground-up replacement for **Blastware** — Instantel's aging Windows-only
software for managing seismographs. Supports both the **MiniMate Plus
@@ -95,6 +95,25 @@ over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
>
> ⚠ The deploy owes a backfill; it does not move event times. See the
> changelog's *Migration*.
>
> **v0.34.0 (2026-11-04)** reaches Series-4 parity and reads most of
> Blastware's report from the event file alone.
> - **Series-4 parity:** one device door by serial for both series, with
> reads, downloads, start/stop, call-home and settings changes, each audited
> and read back. MiniMate request framing is fixed (#46).
> - **The file-only decode:** 47 of Blastware's 88 report fields match on
> every DL2 event, and 8 more on all but one or two.
> - Sensitive-range events are no longer 8× high.
> - Histograms decode correctly and carry Blastware's own times (#51).
> - Interval frequencies follow the sample rate (#50).
> - New from the file: the job number, serial, version, calibration,
> battery, trigger source and levels, interval detail, peak times and
> peak acceleration.
> - **Events are identified by unit + time + type.**
>
> ⚠ The deploy migrates the events table and owes an overnight backfill that
> moves every Series-3 histogram time by one second. See the changelog's
> *Migration*.
> See [CHANGELOG.md](CHANGELOG.md) for full version history.
---