fix(device_access): a start's read-back waits out the sensor check, then wakes the MiniMate with retries

Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.

- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
  every attempt_s until the unit answers, then the POLL data step; a named
  timeout at the deadline.  Reads only.  MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
  (30 s) before asking; every read then wakes with retries (every 5 s, up to
  60 s).  A stop is unchanged -- its read-back was confirmed three times tonight.

Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-27 00:02:10 -04:00
1 parent 9886422212
commit ca5c401c6f
6 files changed
+166 -9

No files matched your search

+24 -6
View File
@@ -43,14 +43,23 @@ def s3_run_state(status: Any) -> str:
return S3_RUN_STATES.get(flag, f"unknown(0x{flag:02X})")
# A start makes the unit run its sensor check before "Recording..." -- ~30 s
# (Brian, 2026-10-26), ~40 s on BE11529 (2026-04-08). A start's read-back waits
# this long before asking, then wakes the unit with retries (S3_WAKE_*).
S3_SENSOR_CHECK_S = 30.0
S3_WAKE_ATTEMPT_S = 5.0
S3_WAKE_DEADLINE_S = 60.0
def _woken_state(client: Any) -> str:
"""The run state, read after waking the unit: SESSION_RESET + POLL first.
"""The run state, read after waking the unit: SESSION_RESET + POLL first,
re-sent until it answers.
A monitoring MiniMate ignores a bare request until it is woken (measured
2026-04-08). On 2026-10-26 BE9441 acked a start, then let a bare 0x1C go
unanswered for 120 s -- the read-back had relied on the connect's wake,
which a stop's read-back (the unit idle by then) never needed."""
client.poll()
2026-04-08). On 2026-10-26 BE9441 acked a start, then left a bare 0x1C, and
later a single SESSION_RESET + POLL, unanswered for 120 s: both went out 2 s
after the start, inside the sensor check, and were never re-sent."""
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
return s3_run_state(client.get_monitor_status())
@@ -209,17 +218,26 @@ class Series3Adapter:
"data_len": 0, "expect_ack": f"0x{ack_sub:02X}",
"frame": build_bw_write_frame(sub, b"").hex()}]}
settle: list = []
def send() -> dict:
# The client validates the ack SUB; it returns nothing else, so none is claimed.
(client.start_monitoring if start else client.stop_monitoring)()
if start:
settle.append(S3_SENSOR_CHECK_S) # the first read waits out the check
return {"subs": [f"0x{ack_sub:02X}"]}
def read_state() -> str:
if settle:
sleep(settle.pop())
return _woken_state(client)
return run_change(
serial=serial, series=3, start=start, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller,
sleep=sleep, verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial,
read_state=lambda: _woken_state(client),
read_state=read_state,
describe_plan=describe_plan, send=send)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT, retry=False)