fix(device_access): a start's read-back waits out the sensor check, then wakes the MiniMate with retries

Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.

- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
  every attempt_s until the unit answers, then the POLL data step; a named
  timeout at the deadline.  Reads only.  MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
  (30 s) before asking; every read then wakes with retries (every 5 s, up to
  60 s).  A stop is unchanged -- its read-back was confirmed three times tonight.

Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-27 00:02:10 -04:00
1 parent 9886422212
commit ca5c401c6f
6 files changed
+166 -9

No files matched your search

+3
View File
@@ -105,6 +105,9 @@ class FakeMiniMateClient(_Base):
def poll(self) -> None:
self._step("poll")
def wake(self, **kw) -> None:
self._step("wake")
def get_monitor_status(self) -> MonitorStatus:
self._step("get_monitor_status")
state = self.monitor_states.pop(0) if len(self.monitor_states) > 1 else self.monitor_states[0]