merge: dev into feat/series4-sfm-parity -- the geophone range from the file, and v0.33.0

Brings 057df47 (fix 4844135, changelog be58b4f) from the decode checker's branch
-- Event.geo_range from the file's setup channel block (label+29: 0 Normal,
1 Sensitive, None not read), peaks and histogram PVS scaled by it,
write_event_hdf5(geo_range=None) using it -- and dev's v0.33.0 release commit
(6c7c6b0).

Conflicts, resolved as agreed with the decode session:
- sfm/waveform_store.py save_imported_bw: dev dropped the forced
  geo_range="normal"; this branch keeps its geo_range parameter, now
  Optional, default None -- an import uses the file's own range, an explicit
  value (a live download's) still wins.
- CLAUDE.md: dev's newer 'Where things stand (updated 2026-11-01)' date.

Measured on the merged tree: K557J1KB.RQ0W (Sensitive waveform) decodes
0.019 / 0.055 / 0.019, PVS 0.061 -- Blastware's report -- and its imported
.h5 peaks 0.0194 / 0.055 / 0.0194 (forcing 'normal' gives 8x: 0.155 / 0.44).
M010HR6K.OA0H (Sensitive histogram) likewise.  The live path still passes the
unit's 1A range or 'normal' when unread -- unchanged by this merge.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 12:06:35 -05:00
commit d0c14aaec8
17 files changed
+3724 -62

No files matched your search

+3
View File
@@ -543,6 +543,9 @@ class Event:
total_samples: Optional[int] = None # from STRT record: expected total sample-sets
pretrig_samples: Optional[int] = None # from STRT record: pre-trigger sample count
rectime_seconds: Optional[int] = None # from STRT record: record duration (seconds)
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
geo_range: Optional[int] = None
# Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring