merge: dev into feat/series4-sfm-parity -- the geophone range from the file, and v0.33.0

Brings 057df47 (fix 4844135, changelog be58b4f) from the decode checker's branch
-- Event.geo_range from the file's setup channel block (label+29: 0 Normal,
1 Sensitive, None not read), peaks and histogram PVS scaled by it,
write_event_hdf5(geo_range=None) using it -- and dev's v0.33.0 release commit
(6c7c6b0).

Conflicts, resolved as agreed with the decode session:
- sfm/waveform_store.py save_imported_bw: dev dropped the forced
  geo_range="normal"; this branch keeps its geo_range parameter, now
  Optional, default None -- an import uses the file's own range, an explicit
  value (a live download's) still wins.
- CLAUDE.md: dev's newer 'Where things stand (updated 2026-11-01)' date.

Measured on the merged tree: K557J1KB.RQ0W (Sensitive waveform) decodes
0.019 / 0.055 / 0.019, PVS 0.061 -- Blastware's report -- and its imported
.h5 peaks 0.0194 / 0.055 / 0.0194 (forcing 'normal' gives 8x: 0.155 / 0.44).
M010HR6K.OA0H (Sensitive histogram) likewise.  The live path still passes the
unit's 1A range or 'normal' when unread -- unchanged by this merge.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 12:06:35 -05:00
commit d0c14aaec8
17 files changed
+3724 -62

No files matched your search

+107
View File
@@ -6,6 +6,71 @@ All notable changes to seismo-relay are documented here.
## Unreleased ## Unreleased
### Fixed
- **A Blastware file's geophone range comes from its setup, so Sensitive
events no longer read 8× high.**
- **Where it is:** in the setup's channel blocks, the byte 29 after each
geophone label. `0x00` is Normal (10 in/s full scale), `0x01` is Sensitive
(1.25 in/s). SFM's live 1A read has the same byte at label+33.
- **Measured:** it matches Blastware's GeoRange on 70,042 / 70,042 DL2
events, all three channels agreeing on every one (35 Sensitive).
- **Before:** SFM assumed Normal, so every Sensitive event's peaks, vector
sum and `.h5` samples read 8× high.
- **`Event.geo_range`** is new: 0 or 1, or None when it isn't read (the
channels disagree, an unknown value, or a missing block). None comes with
a `decode_problems` entry, and peaks then assume Normal as before.
- **`decode_blastware_bytes`** scales peaks and the histogram vector sum by
the range.
- **`event_hdf5.write_event_hdf5`:** `geo_range` now defaults to None,
meaning the event's own range, else Normal. An explicit argument still
wins.
- **`waveform_store.save_imported_bw` and `scripts/backfill_sidecars.py`**
no longer force `"normal"`. The `waveform_store` line was agreed with the
parity session, which owns that file.
- **Decode checker:** GeoRange 70,042 / 70,042, and geophone samples exact
on **6,524 / 6,524** waveforms (was 6,491). PPV mismatches about halved,
and 10 of 88 fields fully match (was 6). 70,287 comparisons fixed, 0
regressions.
- ⚠ **Codec change: bump `TOOL_VERSION` at the next release.** The backfill
(`backfill_sidecars.py` then `backfill_event_shape.py`) rewrites stored
Sensitive events' peaks and `.h5` files. No schema change.
## v0.33.0 — 2026-11-01
**SFM reads Series-3 events from the file alone, and proves it against
Blastware.**
**What was broken.** A Blastware event that reached SFM without its ASCII
report used to come in half-decoded:
- no sample rate
- a "70 s" record time, which was really the record-type byte
- blank notes
- every histogram typed as a waveform
- a histogram vector sum built from channel peaks taken at different moments
- a mic reading about 95× low in psi
That matters more now: every DL2 event from before 2025 arrives with no report,
and SFM's own download and call-in paths never have one.
**What this release does.** It reads all of those from the event file itself,
and adds the decode checker that proves it. The checker compares SFM's
file-only decode, field by field and sample by sample, with Blastware's own
`_XML.XML` event reports for the 70,042 DL2 events that have one (2016–2026).
**Where that stands now:**
- sample rate, record time, pre-trigger, notes and event type match on every
event
- geophone samples are exact on 6,491 / 6,524 waveforms (the 33 others are on
the 1.250 in/s range, which SFM cannot read from the file yet)
- the histogram vector sum matches on 69,919
- the mic matches on all but a few dozen
Events imported with an ASCII report are unchanged on prod; the report still
overlays.
⚠ **This release owes prod a backfill.** It does not move stored event times;
see *Migration* below.
### Fixed ### Fixed
- **The mic in psi was ~95× low: one MicL count is 0.25 Pa.** - **The mic in psi was ~95× low: one MicL count is 0.25 Pa.**
- SFM converted mic counts with a "~0.5 psi full-scale" guess (0.0125 / - SFM converted mic counts with a "~0.5 psi full-scale" guess (0.0125 /
@@ -163,6 +228,9 @@ All notable changes to seismo-relay are documented here.
- job number, ZC frequency, acceleration, displacement, time of peak, - job number, ZC frequency, acceleration, displacement, time of peak,
sensor check, battery, calibration, range, units and monitor log sensor check, battery, calibration, range, units and monitor log
are not read yet are not read yet
- Later in this release, the record type (#41), the histogram vector sum
and the mic conversion were fixed. See their entries above; each was
proven by a full checker run with 0 regressions.
- It replaces `scratch/verify_bw_fields_against_xml.py`, added and - It replaces `scratch/verify_bw_fields_against_xml.py`, added and
removed within this release. removed within this release.
- **Operational consequence: none.** Nothing on the ingest path changes. - **Operational consequence: none.** Nothing on the ingest path changes.
@@ -191,6 +259,45 @@ All notable changes to seismo-relay are documented here.
The old section stays below the banner as history. The old section stays below the banner as history.
Docs only: no code or schema change, no migration, `TOOL_VERSION` unchanged. Docs only: no code or schema change, no migration, `TOOL_VERSION` unchanged.
### Migration
⚠ **This release owes prod a backfill.** It does not move stored event times.
**Before you start:**
- `TOOL_VERSION` is bumped to **0.33.0**, which gates the regeneration, so no
`--force` is needed.
- No parser change, so no `--reparse-txt` is needed.
- No schema change.
- **Back up `seismo_relay.db` first.**
**Then, in the `sfm` container, in this order** (the scripts default to
`bridges/captures/seismo_relay.db` and its `waveforms/`):
1. `python scripts/backfill_sidecars.py` re-decodes every Series-3 event file
whose sidecar predates 0.33.0. Sidecars and `.h5` files regenerate, and each
DB row refreshes in place (id and review kept). ⚠ **~2 h on the NAS.**
- **Report-less events** pick up the new values: sample rate, record time,
pre-trigger, notes, record type, histogram vector sum, mic.
- **Report-paired events** keep the report's values.
- **The record type** stays the same for every ACH file (`…W` / `…H`). Only a
histogram stored under a 3-character manual-download name flips from
Waveform to Histogram.
2. `python scripts/backfill_event_shape.py --db-path bridges/captures/seismo_relay.db
--store-root bridges/captures/waveforms` recomputes the shape and offset
metrics from the regenerated files.
Series-4 (Thor) events are untouched; nothing in their decode changed.
**Not rehearsed on a prod snapshot** (v0.32.0 was). The risk is lower:
- Event times do not move, so every row is matched in place.
- No row is created or removed.
- The full decode checker ran clean against all 70,112 DL2 event files before
release.
**Afterwards**, the DL2 watcher can be widened for the 2016–2024 backfill:
`MAX_EVENT_AGE_DAYS = 2130` reaches 2021. Set it back to 365 when done,
because the same setting widens the heartbeat's scan.
--- ---
## v0.32.0 — 2026-10-27 ## v0.32.0 — 2026-10-27
+31 -25
View File
@@ -2,7 +2,7 @@
Ground-up Python replacement for **Blastware**, Instantel's Windows-only software for Ground-up Python replacement for **Blastware**, Instantel's Windows-only software for
managing MiniMate Plus seismographs. Connects over direct RS-232 or cellular modem managing MiniMate Plus seismographs. Connects over direct RS-232 or cellular modem
(Sierra Wireless RV50 / RV55). Current version: **v0.32.0**. (Sierra Wireless RV50 / RV55). Current version: **v0.33.0**.
Stack-level context — which repo owns what, and how the three project versions Stack-level context — which repo owns what, and how the three project versions
pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
@@ -10,36 +10,42 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
--- ---
## Where things stand (updated 2026-10-26) ## Where things stand (updated 2026-11-01)
Read this first when picking the project back up. Read this first when picking the project back up.
- **🔑 The Series-3 decode checker (2026-10-29).** Goal: SFM produces everything - **🔑 The Series-3 decode checker (2026-10-29; v0.33.0).**
Blastware reports, from the event file alone (spec/plan in `docs/superpowers/`). - **Goal:** SFM produces everything Blastware reports, from the event file
Run it with `scratch/check_s3_decode.py ~/dl2-archive/files ~/dl2-archive/xml`. alone (spec and plan in `docs/superpowers/`).
It decodes each event from its bytes only (no filename, no report) and - **Running it:** `scratch/check_s3_decode.py ~/dl2-archive/files
compares every field, sample and interval with Blastware's `_XML.XML`: 70,042 ~/dl2-archive/xml` decodes each event from its bytes only (no filename, no
events, 2016–2026, ~22 min at `--jobs 4`. Run output (`summary.md`, report). It compares every field, sample and interval with Blastware's
`details.json`, `changes.md`) goes to `~/dl2-archive/checker-runs/` and is `_XML.XML`: 70,042 events, 2016–2026, ~22 min at `--jobs 4`.
never committed. The rule: every mismatch is SFM's bug unless a carve-out - **Output** (`summary.md`, `details.json`, `changes.md`) goes to
with evidence covers it. `~/dl2-archive/checker-runs/` and is never committed.
**First full run:** - **The rule:** every mismatch is SFM's bug unless a carve-out with evidence
- ✅ Sample rate, record time, pre-trigger and notes match everywhere. covers it.
- ✅ Geophone samples are exact on 6,491 / 6,524 waveforms in every year. The
33 others are the 1.250 in/s range, 8× under SFM's Normal-range assumption. **As of v0.33.0:**
- ❌ Every histogram reads as a waveform without its filename (#41), and - ✅ **Match on every event:** sample rate, record time, pre-trigger, notes,
their start times are 1 s early (#51). and event type (#41, from STRT[18]).
- ❌ Open findings: - ✅ **Geophone samples** are exact on 6,491 / 6,524 waveforms in every year.
- histogram PVS: SFM takes the vector magnitude of each channel's interval The 33 others are the 1.250 in/s range, 8× under SFM's Normal-range
peak (peaks that may come from different moments); Blastware takes the assumption.
per-interval vector sum - ✅ **Histogram PVS** = the stored per-interval PVS²: 69,919 / 70,042.
- mic psi conversion - ✅ **Mic: one count = 0.25 Pa,** with Blastware's dB offset at 81.9384. It
- mic dB off by 0.05–0.1 on ~1,000 events fails on only a few dozen events.
- ❌ **Open:**
- histogram start times are 1 s early (#51)
- 35 sub-minute (5 s / 2 s) histograms decode wrongly, plus 2 one-minute - 35 sub-minute (5 s / 2 s) histograms decode wrongly, plus 2 one-minute
no-mic histograms (`R352HFZ7`-shaped, likely a separate cause) no-mic histograms (`R352HFZ7`-shaped, likely a separate cause)
- 26 histogram start dates are a day off - 26 histogram start dates are a day off
- ⬜ Not read yet: job number, ZC frequency, acceleration, displacement, time - the per-interval PVS is not stored
of peak, sensor check, battery, calibration, range, units, monitor log. - Blastware prints `OORANGE` when the vector sum alone exceeds the range
(a carve-out to prove)
- ⬜ **Not read yet:** job number, ZC frequency, acceleration, displacement,
time of peak, sensor check, battery, calibration, range, units, monitor
log.
- **The Series-4 LIVE wire protocol is reverse-engineered end to end - **The Series-4 LIVE wire protocol is reverse-engineered end to end
(2026-09-25).** `docs/micromate_protocol_reference.md` is the Series-4 (2026-09-25).** `docs/micromate_protocol_reference.md` is the Series-4
Rosetta Stone, sibling to `instantel_protocol_reference.md`. **A Micromate Rosetta Stone, sibling to `instantel_protocol_reference.md`. **A Micromate
+32 -2
View File
@@ -1,4 +1,4 @@
# seismo-relay `v0.32.0` # seismo-relay `v0.33.0`
A ground-up replacement for **Blastware** — Instantel's aging Windows-only A ground-up replacement for **Blastware** — Instantel's aging Windows-only
software for managing seismographs. Supports both the **MiniMate Plus software for managing seismographs. Supports both the **MiniMate Plus
@@ -74,6 +74,27 @@ over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
> >
> ⚠ The deploy owes a backfill and moves stored waveform times; see the > ⚠ The deploy owes a backfill and moves stored waveform times; see the
> changelog's *Migration*. > changelog's *Migration*.
>
> **v0.33.0 (2026-11-01)** reads Series-III events from the file alone, and
> proves it.
> - **Fields now read from the event file** when no Blastware report comes with
> the event:
> - sample rate, record time, pre-trigger and the four notes (#44/#45)
> - the event type (#41)
> - a histogram's peak vector sum, which the unit stores per interval
> - the mic, at one count = 0.25 Pa (it read ~95× low in psi)
>
> This matters for every DL2 event from before 2025, and for SFM's own
> download and call-in paths, none of which have a report.
> - **The decode checker** (`scratch/check_s3_decode.py`) compares SFM's
> file-only decode with Blastware's `_XML.XML` event reports, field by field
> and sample by sample, for 70,042 DL2 events back to 2016:
> - every setup field, the notes and the event type match on every event
> - geophone samples are exact on 6,491 / 6,524 waveforms
> - the histogram vector sum matches on 69,919
>
> ⚠ The deploy owes a backfill; it does not move event times. See the
> changelog's *Migration*.
> See [CHANGELOG.md](CHANGELOG.md) for full version history. > See [CHANGELOG.md](CHANGELOG.md) for full version history.
--- ---
@@ -615,7 +636,16 @@ Implementation steps (concrete):
### High-impact (unblocks product features) ### High-impact (unblocks product features)
- [ ] **Series III waveform body codec reverse-engineering.** The 5A bulk-stream body is some kind of compressed/encoded format (not raw int16 LE as previously assumed — see §7.6.1 retraction in `docs/instantel_protocol_reference.md`). Structural framing is ~50% decoded on branch `claude/codec-re-cBGNe` (tagged-block walker, segment counters); per-byte sample mapping is still open. Until this lands, the in-app waveform viewer renders garbage and BW-import peak values fall back to `_peaks_from_samples()` saturation noise. Workaround: pair every BW-imported event with its `_ASCII.TXT` so the device-authoritative peaks land in the DB regardless of codec. - [x] **Series III waveform body codec reverse-engineering.** ✅ The body codec is fully decoded (`minimateplus/waveform_codec.py`, `histogram_codec.py`), and verified per-sample against Blastware's own exports. As of v0.33.0, geophone samples are exact on 6,491 / 6,524 DL2 waveforms against their `_XML.XML` reports, across 2016–2026.
- [ ] **SFM produces everything Blastware reports, from the event file alone.** The four-piece plan:
1. the decode checker ✅ v0.33.0
2. complete the file-only decode, one field group at a time, each proven by the checker
3. flip ingest so reports are kept only for checking
4. stop the watchers forwarding reports
**Done so far:** setup fields, notes, event type, histogram PVS, mic.
**Next:** histogram start times (#51), the 37 histograms that decode wrongly, the job number, the geophone range (Sensitive-range events read 8×), and the values Blastware computes itself (ZC frequency, acceleration, displacement, time of peak), plus the sensor check, battery, calibration and monitor log. Design: `docs/superpowers/specs/2026-10-29-s3-decode-checker-design.md`.
- [x] **Series IV (Thor IDF) binary codec reverse-engineering.** ✅ v0.21.0 — `micromate/idf_file.read_idf_file()` decodes both IDFW (waveform body at offset `0x0f1f`, reusing `decode_waveform_v2()`; 87–99% sample fidelity on quiet events) and IDFH (dedicated segment-based decoder: all 859 corpus files decode, 181,071 intervals, peaks within ~1.8% of sidecar values). `WaveformStore.save_imported_idf` now also projects parsed Thor data into a `bw_report` block via `micromate/idf_to_bw_report.py` so Thor events render in the existing Event Report PDF pipeline without a separate renderer. - [x] **Series IV (Thor IDF) binary codec reverse-engineering.** ✅ v0.21.0 — `micromate/idf_file.read_idf_file()` decodes both IDFW (waveform body at offset `0x0f1f`, reusing `decode_waveform_v2()`; 87–99% sample fidelity on quiet events) and IDFH (dedicated segment-based decoder: all 859 corpus files decode, 181,071 intervals, peaks within ~1.8% of sidecar values). `WaveformStore.save_imported_idf` now also projects parsed Thor data into a `bw_report` block via `micromate/idf_to_bw_report.py` so Thor events render in the existing Event Report PDF pipeline without a separate renderer.
- [ ] **In-app waveform viewer accuracy.** Depends on Series III codec decode. Plot.v1 JSON pipeline + viewer skeleton already exist; will start showing real waveforms automatically once `_decode_a5_waveform` produces correct samples. Series IV waveforms come online when the IDF codec lands. - [ ] **In-app waveform viewer accuracy.** Depends on Series III codec decode. Plot.v1 JSON pipeline + viewer skeleton already exist; will start showing real waveforms automatically once `_decode_a5_waveform` produces correct samples. Series IV waveforms come online when the IDF codec lands.
- [ ] **Series IV live-device support.** Once the IDF binary is decoded, extend `micromate/` with `transport.py` / `framing.py` / `protocol.py` / `client.py` mirroring the `minimateplus/` package layout — depends on capturing Thor's wire protocol (TCP / RS-232 captures TBD). - [ ] **Series IV live-device support.** Once the IDF binary is decoded, extend `micromate/` with `transport.py` / `framing.py` / `protocol.py` / `client.py` mirroring the `minimateplus/` package layout — depends on capturing Thor's wire protocol (TCP / RS-232 captures TBD).
+14 -9
View File
@@ -18,12 +18,13 @@ from dataclasses import dataclass
from typing import Callable, Optional, Sequence from typing import Callable, Optional, Sequence
from .bw_xml_report import XmlReport from .bw_xml_report import XmlReport
from .event_file_io import _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT, decode_blastware_bytes from .event_file_io import (_GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
decode_blastware_bytes)
from .models import Event from .models import Event
from .waveform_codec import mic_count_to_db from .waveform_codec import mic_count_to_db
# SFM's conversion: it cannot yet read the geophone range from the file, and # SFM's conversion at the Normal range (10 in/s full scale = 32000 counts),
# assumes Normal (10 in/s full scale = 32000 counts). # which SFM assumes when it cannot read the event's range from the file.
GEO_IPS_PER_COUNT: float = _GEO_NORMAL_FS_INS / _GEO_INT16_FS GEO_IPS_PER_COUNT: float = _GEO_NORMAL_FS_INS / _GEO_INT16_FS
_CHANNELS = ("Tran", "Vert", "Long", "MicL") _CHANNELS = ("Tran", "Vert", "Long", "MicL")
@@ -38,6 +39,7 @@ class SfmSide:
job_number: Optional[str] # None until the decoder reads it job_number: Optional[str] # None until the decoder reads it
channels: list[str] # channels with decoded data, in Tran/Vert/Long/MicL order channels: list[str] # channels with decoded data, in Tran/Vert/Long/MicL order
counts: dict[str, list[int]] # waveform samples or histogram interval peaks counts: dict[str, list[int]] # waveform samples or histogram interval peaks
geo_ips_per_count: float = GEO_IPS_PER_COUNT # at the event's range, as SFM read it
def sfm_side(raw: bytes) -> SfmSide: def sfm_side(raw: bytes) -> SfmSide:
@@ -55,6 +57,7 @@ def sfm_side(raw: bytes) -> SfmSide:
# SFM's interval count is its decoded entry count; the reference # SFM's interval count is its decoded entry count; the reference
# carries this field for histograms only. # carries this field for histograms only.
"NumberofIntervals": len(counts["Tran"]) or None, "NumberofIntervals": len(counts["Tran"]) or None,
"GeoRange": _GEO_FS_BY_RANGE.get(ev.geo_range),
} }
if ts is not None: if ts is not None:
date = f"{ts.year:04d}-{ts.month:02d}-{ts.day:02d}" date = f"{ts.year:04d}-{ts.month:02d}-{ts.day:02d}"
@@ -78,6 +81,7 @@ def sfm_side(raw: bytes) -> SfmSide:
job_number=None, job_number=None,
channels=[ch for ch in _CHANNELS if counts[ch]], channels=[ch for ch in _CHANNELS if counts[ch]],
counts=counts, counts=counts,
geo_ips_per_count=_GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS) / _GEO_INT16_FS,
) )
@@ -184,19 +188,20 @@ def _series_result(field: str, n_bw: int, n_sfm: int, diffs: list[tuple[int, flo
) )
def _sample_converters(ref: XmlReport) -> dict[str, Callable[[int], float]]: def _sample_converters(sfm: SfmSide, ref: XmlReport) -> dict[str, Callable[[int], float]]:
convert: dict[str, Callable[[int], float]] = {ch: (lambda c: c * GEO_IPS_PER_COUNT) for ch in _GEO} k = sfm.geo_ips_per_count
convert: dict[str, Callable[[int], float]] = {ch: (lambda c: c * k) for ch in _GEO}
mic = _mic_converter(ref) mic = _mic_converter(ref)
if mic is not None: if mic is not None:
convert["MicL"] = mic convert["MicL"] = mic
return convert return convert
def _interval_converter(title: str) -> Optional[Callable[[int], float]]: def _interval_converter(title: str, sfm: SfmSide) -> Optional[Callable[[int], float]]:
"""SFM keeps each interval's peaks; it drops their frequencies and geo PVS.""" """SFM keeps each interval's peaks; it drops their frequencies and geo PVS."""
ch, _, rest = title.partition(" ") ch, _, rest = title.partition(" ")
if rest.startswith("Peak") and ch in _GEO: if rest.startswith("Peak") and ch in _GEO:
return lambda c: c * GEO_IPS_PER_COUNT return lambda c: c * sfm.geo_ips_per_count
if ch == "MicL" and rest == "Peak dB(L)": if ch == "MicL" and rest == "Peak dB(L)":
return mic_count_to_db return mic_count_to_db
if ch == "MicL" and rest == "Peak psi(L)": if ch == "MicL" and rest == "Peak psi(L)":
@@ -215,7 +220,7 @@ def series_pairs(sfm: SfmSide, ref: XmlReport,
a row whose cell count differs is a disagreement for every channel.""" a row whose cell count differs is a disagreement for every channel."""
if field.startswith("samples."): if field.startswith("samples."):
ch = field[len("samples."):] ch = field[len("samples."):]
convert = _sample_converters(ref).get(ch) convert = _sample_converters(sfm, ref).get(ch)
counts = sfm.counts.get(ch, []) counts = sfm.counts.get(ch, [])
if convert is None or not counts: if convert is None or not counts:
return None return None
@@ -232,7 +237,7 @@ def series_pairs(sfm: SfmSide, ref: XmlReport,
if field.startswith("intervals."): if field.startswith("intervals."):
title = field[len("intervals."):] title = field[len("intervals."):]
columns = ref.interval_columns or [] columns = ref.interval_columns or []
convert = _interval_converter(title) convert = _interval_converter(title, sfm)
counts = sfm.counts.get(title.partition(" ")[0], []) counts = sfm.counts.get(title.partition(" ")[0], [])
if convert is None or not counts or title not in columns: if convert is None or not counts or title not in columns:
return None return None
+48 -12
View File
@@ -51,7 +51,7 @@ SIDECAR_KIND = "sfm.event"
# bumped without a `pip install` re-run — leading to confusing stale # bumped without a `pip install` re-run — leading to confusing stale
# version stamps in sidecars. Bump this constant and CHANGELOG.md # version stamps in sidecars. Bump this constant and CHANGELOG.md
# together at release time. # together at release time.
TOOL_VERSION = "0.32.0" # waveform times from the event record, report dates, histogram reader; gates the backfill regen TOOL_VERSION = "0.33.0" # setup + notes, record type, histogram PVS and mic from the file; gates the backfill regen
try: try:
# Best-effort: prefer the installed metadata when it's NEWER than the # Best-effort: prefer the installed metadata when it's NEWER than the
@@ -704,9 +704,11 @@ _INT16_FS = 32768.0
# sfm.event_hdf5._GEO_INT16_FS or sidecar peaks disagree with the plotted # sfm.event_hdf5._GEO_INT16_FS or sidecar peaks disagree with the plotted
# waveform by 2.3%. Confirmed 2026-08-25 against the BW ASCII corpus. # waveform by 2.3%. Confirmed 2026-08-25 against the BW ASCII corpus.
_GEO_INT16_FS = 32000.0 _GEO_INT16_FS = 32000.0
# A histogram's geo values are in decoder units of 16 counts = 0.005 in/s at # Full scale per geo_range: 0 Normal, 1 Sensitive.
# the Normal range (the same assumption as the samples above). _GEO_FS_BY_RANGE = {0: _GEO_NORMAL_FS_INS, 1: _GEO_SENSITIVE_FS_INS}
_HIST_GEO_UNIT_INS = 16 * _GEO_NORMAL_FS_INS / _GEO_INT16_FS # A histogram's geo values are decoder units of 16 counts: 0.005 in/s at the
# Normal range, scaled by the range's full scale like the samples above.
_HIST_GEO_COUNTS_PER_UNIT = 16
# Microphone scale factor, psi per MicL count: one count is 0.25 Pa # Microphone scale factor, psi per MicL count: one count is 0.25 Pa
# (waveform_codec.MIC_PA_PER_COUNT, measured against Blastware's psi(L) on # (waveform_codec.MIC_PA_PER_COUNT, measured against Blastware's psi(L) on
@@ -749,17 +751,19 @@ def _decode_samples_4ch_int16_le(stream: bytes) -> dict[str, list[int]]:
} }
def _peaks_from_samples(samples: dict[str, list[int]]) -> PeakValues: def _peaks_from_samples(samples: dict[str, list[int]],
geo_fs_ins: float = _GEO_NORMAL_FS_INS) -> PeakValues:
""" """
Compute approximate peaks from raw int16 samples assuming Normal-range Compute peaks from raw int16 samples at the given geophone full scale
geophone sensitivity. Used by the BW-importer when the 0C waveform (Normal, 10 in/s, unless the file's range says otherwise). Used by the
record (the device's authoritative peaks) is unavailable. BW-importer when the 0C waveform record (the device's authoritative peaks)
is unavailable.
""" """
def _peak_ins(ch: list[int]) -> float: def _peak_ins(ch: list[int]) -> float:
if not ch: if not ch:
return 0.0 return 0.0
m = max(abs(int(v)) for v in ch) m = max(abs(int(v)) for v in ch)
return m / _GEO_INT16_FS * _GEO_NORMAL_FS_INS return m / _GEO_INT16_FS * geo_fs_ins
tran = _peak_ins(samples.get("Tran", [])) tran = _peak_ins(samples.get("Tran", []))
vert = _peak_ins(samples.get("Vert", [])) vert = _peak_ins(samples.get("Vert", []))
@@ -773,7 +777,7 @@ def _peaks_from_samples(samples: dict[str, list[int]]) -> PeakValues:
pvs = 0.0 pvs = 0.0
n = min(len(samples.get("Tran", [])), len(samples.get("Vert", [])), len(samples.get("Long", []))) n = min(len(samples.get("Tran", [])), len(samples.get("Vert", [])), len(samples.get("Long", [])))
if n: if n:
scale = _GEO_NORMAL_FS_INS / _GEO_INT16_FS scale = geo_fs_ins / _GEO_INT16_FS
T = samples["Tran"]; V = samples["Vert"]; L = samples["Long"] T = samples["Tran"]; V = samples["Vert"]; L = samples["Long"]
for i in range(n): for i in range(n):
t = T[i] * scale t = T[i] * scale
@@ -996,6 +1000,32 @@ def _setup_notes(raw: bytes) -> ProjectInfo:
operator=operator, sensor_location=location) operator=operator, sensor_location=location)
# The geophone range sits in the setup's channel blocks, which follow the
# notes: the byte 29 after each geophone label (`00 00 01 Tran ...`). 0x00 is
# Normal, 0x01 Sensitive -- Blastware's GeoRange on 70,042 / 70,042 DL2 events,
# all three channels agreeing on every one (measured 2026-11-01). SFM's live
# 1A read has the same byte at label+33.
_RANGE_AFTER_LABEL = 29
_CHANNEL_BLOCK_SPAN = 2000 # how far past the setup name the blocks may sit
def _setup_geo_range(raw: bytes) -> tuple[Optional[int], Optional[str]]:
"""(geo_range, problem): 0 Normal or 1 Sensitive when all three geophone
channels say the same, else None and why."""
k = _setup_name_at(raw)
if k is None:
return None, "no recording-setup block to read the geophone range from"
found = {}
for label in (b"Tran", b"Vert", b"Long"):
i = raw.find(b"\x00\x00\x01" + label, k, k + _CHANNEL_BLOCK_SPAN)
p = i + 3 + _RANGE_AFTER_LABEL
found[label.decode()] = raw[p] if i >= 0 and p < len(raw) else None
values = set(found.values())
if len(values) == 1 and values <= {0, 1}:
return values.pop(), None
return None, f"geophone range not read: channel range bytes {found}"
def read_blastware_file(path: Union[str, Path], *, name: Optional[str] = None) -> Event: def read_blastware_file(path: Union[str, Path], *, name: Optional[str] = None) -> Event:
"""Parse a Blastware event file into an Event: `decode_blastware_bytes` on its """Parse a Blastware event file into an Event: `decode_blastware_bytes` on its
bytes, `name` defaulting to the file's own (see there -- never a time source).""" bytes, `name` defaulting to the file's own (see there -- never a time source)."""
@@ -1156,6 +1186,9 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
# every waveform used to read "70 s". A histogram has no record time or # every waveform used to read "70 s". A histogram has no record time or
# pre-trigger -- Blastware reports neither. # pre-trigger -- Blastware reports neither.
ev.sample_rate = _setup_sample_rate(raw) ev.sample_rate = _setup_sample_rate(raw)
ev.geo_range, range_problem = _setup_geo_range(raw)
if range_problem:
ev.decode_problems.append(range_problem + "; peaks assume the Normal range")
if is_waveform_body: if is_waveform_body:
ev.rectime_seconds = _setup_record_time(raw) ev.rectime_seconds = _setup_record_time(raw)
ev.total_samples = len(samples["Tran"]) or None ev.total_samples = len(samples["Tran"]) or None
@@ -1244,14 +1277,17 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
# None, and ``apply_report_to_event`` overlays from a paired ASCII # None, and ``apply_report_to_event`` overlays from a paired ASCII
# report when one is supplied. # report when one is supplied.
has_samples = any(samples.get(ch) for ch in ("Tran", "Vert", "Long", "MicL")) has_samples = any(samples.get(ch) for ch in ("Tran", "Vert", "Long", "MicL"))
ev.peak_values = _peaks_from_samples(samples) if has_samples else None # The geophone full scale is the file's range; Normal when it wasn't read.
geo_fs = _GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS)
ev.peak_values = _peaks_from_samples(samples, geo_fs) if has_samples else None
if not is_waveform_body and ev.peak_values is not None: if not is_waveform_body and ev.peak_values is not None:
# A histogram stores each interval's vector sum (squared); the event's # A histogram stores each interval's vector sum (squared); the event's
# is the largest. Combining the channel peaks instead read high on 86% # is the largest. Combining the channel peaks instead read high on 86%
# of DL2's histograms -- they can come from different moments. # of DL2's histograms -- they can come from different moments.
pvs = interval_pvs(body) pvs = interval_pvs(body)
if pvs: if pvs:
ev.peak_values.peak_vector_sum = max(pvs) * _HIST_GEO_UNIT_INS ev.peak_values.peak_vector_sum = (
max(pvs) * _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS)
ev._a5_frames = None # not recoverable from BW file ev._a5_frames = None # not recoverable from BW file
return ev return ev
+3
View File
@@ -543,6 +543,9 @@ class Event:
total_samples: Optional[int] = None # from STRT record: expected total sample-sets total_samples: Optional[int] = None # from STRT record: expected total sample-sets
pretrig_samples: Optional[int] = None # from STRT record: pre-trigger sample count pretrig_samples: Optional[int] = None # from STRT record: pre-trigger sample count
rectime_seconds: Optional[int] = None # from STRT record: record duration (seconds) rectime_seconds: Optional[int] = None # from STRT record: record duration (seconds)
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
geo_range: Optional[int] = None
# Sensor self-check traces keyed by channel label — the short diagnostic # Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring # waveforms the unit records when it pulses each sensor before monitoring
+1 -1
View File
@@ -4,7 +4,7 @@ build-backend = "setuptools.build_meta"
[project] [project]
name = "seismo-relay" name = "seismo-relay"
version = "0.32.0" version = "0.33.0"
description = "Python client and REST server for MiniMate Plus seismographs" description = "Python client and REST server for MiniMate Plus seismographs"
requires-python = ">=3.10" requires-python = ">=3.10"
dependencies = [ dependencies = [
+1 -2
View File
@@ -428,8 +428,7 @@ def main(argv=None) -> int:
try: try:
event_hdf5.write_event_hdf5( event_hdf5.write_event_hdf5(
hdf5_path, ev, hdf5_path, ev,
serial=serial, serial=serial, # range: the event's own, from its setup
geo_range="normal",
source_kind=source_kind, source_kind=source_kind,
) )
hdf5_filename = hdf5_path.name hdf5_filename = hdf5_path.name
+6 -1
View File
@@ -180,7 +180,7 @@ def write_event_hdf5(
event: Event, event: Event,
*, *,
serial: str, serial: str,
geo_range = "normal", geo_range = None,
source_kind: str = "sfm-live", source_kind: str = "sfm-live",
tool_version: Optional[str] = None, tool_version: Optional[str] = None,
captured_at: Optional[datetime.datetime] = None, captured_at: Optional[datetime.datetime] = None,
@@ -190,6 +190,9 @@ def write_event_hdf5(
""" """
Persist a decoded Event as an HDF5 file with samples in physical units. Persist a decoded Event as an HDF5 file with samples in physical units.
``geo_range`` left as None takes the event's own (``event.geo_range``,
which a Blastware file's decode reads from its setup block), else Normal.
``geo_ips_per_count`` overrides the range-derived MiniMate count scale ``geo_ips_per_count`` overrides the range-derived MiniMate count scale
for sources whose counts differ — Thor IDF imports pass for sources whose counts differ — Thor IDF imports pass
``micromate.idf_file._GEO_LSB_IPS`` (issue #42). ``micromate.idf_file._GEO_LSB_IPS`` (issue #42).
@@ -202,6 +205,8 @@ def write_event_hdf5(
pv = event.peak_values pv = event.peak_values
pi = event.project_info pi = event.project_info
if geo_range is None:
geo_range = event.geo_range if getattr(event, "geo_range", None) is not None else "normal"
geo_fs = _resolve_geo_full_scale(geo_range) geo_fs = _resolve_geo_full_scale(geo_range)
geo_range_str = _normalise_range(geo_range) geo_range_str = _normalise_range(geo_range)
captured_at = captured_at or datetime.datetime.utcnow() captured_at = captured_at or datetime.datetime.utcnow()
+4 -3
View File
@@ -298,7 +298,7 @@ class WaveformStore:
serial_hint: Optional[str] = None, serial_hint: Optional[str] = None,
bw_report_text: Optional[Union[str, bytes]] = None, bw_report_text: Optional[Union[str, bytes]] = None,
source_kind: str = "bw-import", source_kind: str = "bw-import",
geo_range: Union[str, int] = "normal", geo_range: Optional[Union[str, int]] = None,
) -> tuple[Event, dict]: ) -> tuple[Event, dict]:
""" """
Ingest a Blastware event file produced by an external tool Ingest a Blastware event file produced by an external tool
@@ -417,8 +417,9 @@ class WaveformStore:
event_hdf5.write_event_hdf5( event_hdf5.write_event_hdf5(
hdf5_path, ev, hdf5_path, ev,
serial=serial, serial=serial,
# The BW file doesn't carry the range (yet); an import assumes Normal, # None (an import): the event's own range, read from the file's
# a live download passes the unit's own (event_ingest). # setup (ev.geo_range), else Normal. An explicit value -- a live
# download's (event_ingest) -- wins.
geo_range=geo_range, geo_range=geo_range,
source_kind="bw-import", source_kind="bw-import",
) )
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
BIN
View File
Binary file not shown.
+167
View File
@@ -0,0 +1,167 @@
<?xml version="1.0" encoding="UTF-8"?>
<Event>
<FileVersion>8.0</FileVersion>
<EventType>Full Histogram</EventType>
<SerialNumber>BE11010</SerialNumber>
<Version>V 10.72-8.17 MiniMate Plus</Version>
<FileName>M010HR6K.OA0H</FileName>
<HistogramStartTime>17:02:34</HistogramStartTime>
<HistogramStartDate>2019-01-08</HistogramStartDate>
<HistogramStopTime>17:20:00</HistogramStopTime>
<HistogramStopDate>2019-01-08</HistogramStopDate>
<Channels>
<Channel>Tran</Channel>
<Channel>Vert</Channel>
<Channel>Long</Channel>
<Channel>MicL</Channel>
</Channels>
<NumberofIntervals>18.00</NumberofIntervals>
<IntervalSize>1 minute</IntervalSize>
<SampleRate>1024 sps</SampleRate>
<BatteryLevel>6.8 Volts</BatteryLevel>
<Calibration>December 17, 2018 by Instantel</Calibration>
<Units>in/s and dB(L)</Units>
<Project>Wampum Ave-ECMS 29301-215 Joseph St</Project>
<Client>Brayman Construction</Client>
<UserName>Terra-Mechanics Inc - D. Bartholomae</UserName>
<Seis.Loc>Loc, #1 - 215 Joseph Street</Seis.Loc>
<GeoRange>
<Value>1.250</Value>
<Units>in/s</Units>
</GeoRange>
<TranPPV>
<Value>0.008</Value>
<Units>in/s</Units>
</TranPPV>
<VertPPV>
<Value>0.009</Value>
<Units>in/s</Units>
</VertPPV>
<LongPPV>
<Value>0.005</Value>
<Units>in/s</Units>
</LongPPV>
<TranZCFreq>
<Value>11</Value>
<Units>Hz</Units>
</TranZCFreq>
<VertZCFreq>
<Value>73</Value>
<Units>Hz</Units>
</VertZCFreq>
<LongZCFreq>
<Value>16</Value>
<Units>Hz</Units>
</LongZCFreq>
<TranPeakTime>17:11:34</TranPeakTime>
<TranPeakDate>2019-01-08</TranPeakDate>
<VertPeakTime>17:03:34</VertPeakTime>
<VertPeakDate>2019-01-08</VertPeakDate>
<LongPeakTime>17:11:34</LongPeakTime>
<LongPeakDate>2019-01-08</LongPeakDate>
<PeakVectorSum>
<Value>0.009</Value>
<Units>in/s</Units>
</PeakVectorSum>
<PeakVectorSumTime>17:11:34</PeakVectorSumTime>
<PeakVectorSumDate>2019-01-08</PeakVectorSumDate>
<Microphone>Linear Weighting</Microphone>
<MicLPSPL>
<Value>134.1</Value>
<Units>dB(L)</Units>
</MicLPSPL>
<MicLTime>17:03:34</MicLTime>
<MicLDate>2019-01-08</MicLDate>
<MicLZCFreq>
<Value>9.7</Value>
<Units>Hz</Units>
</MicLZCFreq>
<TranTestFreq>7.2 Hz.</TranTestFreq>
<TranTestRatio>4.3</TranTestRatio>
<TranTestResults>Passed</TranTestResults>
<VertTestFreq>7.6 Hz.</VertTestFreq>
<VertTestRatio>3.4</VertTestRatio>
<VertTestResults>Passed</VertTestResults>
<LongTestFreq>7.2 Hz.</LongTestFreq>
<LongTestRatio>3.8</LongTestRatio>
<LongTestResults>Passed</LongTestResults>
<MicLTestFreq>20.1 Hz.</MicLTestFreq>
<MicLTestAmplitude>583 mv</MicLTestAmplitude>
<MicLTestResults>Passed</MicLTestResults>
<UsbSummaryChannels>
</UsbSummaryChannels>
<MonitorLog>2019-01-08 17:02:33 - 2019-01-08 17:20:00 &quot;Event Recorded Modem Exit&quot;</MonitorLog>
<HistogramData>
<HistogramDataColumnTitle>
<ColumnTitle> Tran Peak in/s </ColumnTitle>
<ColumnTitle> Tran Freq Hz </ColumnTitle>
<ColumnTitle> Vert Peak in/s </ColumnTitle>
<ColumnTitle> Vert Freq Hz </ColumnTitle>
<ColumnTitle> Long Peak in/s </ColumnTitle>
<ColumnTitle> Long Freq Hz </ColumnTitle>
<ColumnTitle> Geo PVS in/s </ColumnTitle>
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
<ColumnTitle> MicL Freq Hz </ColumnTitle>
</HistogramDataColumnTitle>
<HistogramDataIntervals>
<Time>2019-01-08 17:03:34</Time>
<Row>
<Cell>0.003</Cell><Cell>47</Cell><Cell>0.009</Cell><Cell>73</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.009</Cell><Cell>0.015</Cell><Cell>134.1</Cell><Cell>9.7</Cell></Row>
<Time>2019-01-08 17:04:34</Time>
<Row>
<Cell>0.003</Cell><Cell>21</Cell><Cell>0.007</Cell><Cell>27</Cell><Cell>0.002</Cell><Cell>85</Cell><Cell>0.007</Cell><Cell>0.000</Cell><Cell>87.96</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:05:34</Time>
<Row>
<Cell>0.004</Cell><Cell>20</Cell><Cell>0.004</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.005</Cell><Cell>0.003</Cell><Cell>119.1</Cell><Cell>7.5</Cell></Row>
<Time>2019-01-08 17:06:34</Time>
<Row>
<Cell>0.003</Cell><Cell>34</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>51</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>81.94</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:07:34</Time>
<Row>
<Cell>0.003</Cell><Cell>51</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>39</Cell></Row>
<Time>2019-01-08 17:08:34</Time>
<Row>
<Cell>0.004</Cell><Cell>12</Cell><Cell>0.004</Cell><Cell>16</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.005</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>13</Cell></Row>
<Time>2019-01-08 17:09:34</Time>
<Row>
<Cell>0.002</Cell><Cell>51</Cell><Cell>0.002</Cell><Cell>64</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>81.94</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:10:34</Time>
<Row>
<Cell>0.003</Cell><Cell>12</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.004</Cell><Cell>0.000</Cell><Cell>81.94</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:11:34</Time>
<Row>
<Cell>0.008</Cell><Cell>11</Cell><Cell>0.005</Cell><Cell>13</Cell><Cell>0.005</Cell><Cell>16</Cell><Cell>0.009</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>19</Cell></Row>
<Time>2019-01-08 17:12:34</Time>
<Row>
<Cell>0.006</Cell><Cell>13</Cell><Cell>0.004</Cell><Cell>14</Cell><Cell>0.004</Cell><Cell>51</Cell><Cell>0.007</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>20</Cell></Row>
<Time>2019-01-08 17:13:34</Time>
<Row>
<Cell>0.003</Cell><Cell>57</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>87.96</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:14:34</Time>
<Row>
<Cell>0.003</Cell><Cell>47</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>13</Cell></Row>
<Time>2019-01-08 17:15:34</Time>
<Row>
<Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.004</Cell><Cell>0.000</Cell><Cell>95.92</Cell><Cell>2.5</Cell></Row>
<Time>2019-01-08 17:16:34</Time>
<Row>
<Cell>0.003</Cell><Cell>13</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>85</Cell><Cell>0.004</Cell><Cell>0.000</Cell><Cell>93.98</Cell><Cell>9.1</Cell></Row>
<Time>2019-01-08 17:17:34</Time>
<Row>
<Cell>0.003</Cell><Cell>17</Cell><Cell>0.002</Cell><Cell>85</Cell><Cell>0.002</Cell><Cell>73</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>81.94</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:18:34</Time>
<Row>
<Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.004</Cell><Cell>0.000</Cell><Cell>87.96</Cell><Cell>&gt;100</Cell></Row>
<Time>2019-01-08 17:19:34</Time>
<Row>
<Cell>0.003</Cell><Cell>73</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.003</Cell><Cell>20</Cell><Cell>0.004</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>6.1</Cell></Row>
<Time>2019-01-08 17:20:00</Time>
<Row>
<Cell>0.002</Cell><Cell>37</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.002</Cell><Cell>&gt;100</Cell><Cell>0.003</Cell><Cell>0.000</Cell><Cell>91.48</Cell><Cell>18</Cell></Row>
</HistogramDataIntervals>
</HistogramData>
<HistogramDataUsbChannels>
</HistogramDataUsbChannels>
</Event>
+70
View File
@@ -206,3 +206,73 @@ def test_mic_peak_in_psi():
# Blastware: MicL PSPL 106.0 dB(L) = 20 uPa x 10^(106/20) = 3.990 Pa = 5.787e-4 psi. # Blastware: MicL PSPL 106.0 dB(L) = 20 uPa x 10^(106/20) = 3.990 Pa = 5.787e-4 psi.
ev = read_blastware_file(_FIX / "decode-checker-10-29-26/M529L4XQ.R30H") ev = read_blastware_file(_FIX / "decode-checker-10-29-26/M529L4XQ.R30H")
assert ev.peak_values.micl == pytest.approx(5.787e-4, rel=0.01) assert ev.peak_values.micl == pytest.approx(5.787e-4, rel=0.01)
# ── The geophone range: Normal or Sensitive ─────────────────────────────────
# In the setup's channel blocks, the byte 29 after each geophone label is the
# range: 0x00 Normal (10 in/s full scale), 0x01 Sensitive (1.25 in/s). It
# matches Blastware's GeoRange on 70,042 / 70,042 DL2 events, all three
# channels agreeing on every one (35 Sensitive), measured 2026-11-01. Until
# now SFM assumed Normal, so a Sensitive event read 8x high.
from minimateplus.event_file_io import _setup_name_at # noqa: E402
@pytest.mark.parametrize("rel,want", [
("bw-import-fields-10-29-26/R352HIUI.F40W", 0),
("geo-range-11-01-26/K557J1KB.RQ0W", 1), # waveform, XML GeoRange 1.250
("geo-range-11-01-26/M010HR6K.OA0H", 1), # histogram, XML GeoRange 1.250
])
def test_geo_range_comes_from_the_file(rel, want):
assert read_blastware_file(_FIX / rel).geo_range == want
# (file, Blastware's Tran / Vert / Long PPV and Peak Vector Sum, from its XML)
@pytest.mark.parametrize("rel,peaks", [
("geo-range-11-01-26/K557J1KB.RQ0W", ("0.019", "0.055", "0.019", "0.061")),
("geo-range-11-01-26/M010HR6K.OA0H", ("0.008", "0.009", "0.005", "0.009")),
])
def test_sensitive_range_peaks_are_not_8x(rel, peaks):
pv = read_blastware_file(_FIX / rel).peak_values
for got, want in zip((pv.tran, pv.vert, pv.long, pv.peak_vector_sum), peaks):
assert abs(got - float(want)) <= 0.0005 + 1e-9, (got, want)
def test_channels_that_disagree_give_no_range_and_a_problem():
raw = bytearray((_FIX / "geo-range-11-01-26/K557J1KB.RQ0W").read_bytes())
i = raw.find(b"\x00\x00\x01Vert", _setup_name_at(bytes(raw)))
raw[i + 3 + 29] = 0x00 # Vert Normal, Tran / Long Sensitive
ev = decode_blastware_bytes(bytes(raw), name=None)
assert ev.geo_range is None
assert any("range" in p for p in ev.decode_problems)
def test_the_h5_takes_the_events_range(tmp_path):
import h5py
from sfm import event_hdf5
ev = read_blastware_file(_FIX / "geo-range-11-01-26/K557J1KB.RQ0W")
event_hdf5.write_event_hdf5(tmp_path / "e.h5", ev, serial="BE9557")
with h5py.File(tmp_path / "e.h5", "r") as f:
assert f.attrs["geo_range"] == "sensitive"
assert abs(float(abs(f["samples/Vert"][:]).max()) - 0.055) <= 0.0005 + 1e-9
def test_an_imported_file_and_the_backfill_store_its_range(tmp_path):
import h5py
import scripts.backfill_sidecars as backfill
from sfm import event_hdf5
from sfm.waveform_store import WaveformStore
src = _FIX / "geo-range-11-01-26/K557J1KB.RQ0W"
store = WaveformStore(tmp_path / "waveforms")
ev, _ = store.save_imported_bw(src.read_bytes(), source_path=src)
h5 = store.hdf5_path_for("BE9557", src.name)
with h5py.File(h5, "r") as f:
assert f.attrs["geo_range"] == "sensitive"
# A file stored before this fix carries "normal"; the backfill rewrites it.
event_hdf5.write_event_hdf5(h5, ev, serial="BE9557", geo_range="normal")
assert backfill.main(["--store-root", str(tmp_path / "waveforms"),
"--db-path", str(tmp_path / "seismo_relay.db"), "--force"]) == 0
with h5py.File(h5, "r") as f:
assert f.attrs["geo_range"] == "sensitive"
+3 -2
View File
@@ -28,7 +28,8 @@ def test_find_pairs_dedupes_and_pairs(tmp_path):
def test_check_event_rows_and_attrs(): def test_check_event_rows_and_attrs():
out = run.check_event("M007HVWF.K30W", str(FIX / "M007HVWF.K30W"), str(FIX / "M007HVWF_K30W_XML.XML")) out = run.check_event("M007HVWF.K30W", str(FIX / "M007HVWF.K30W"), str(FIX / "M007HVWF_K30W_XML.XML"))
assert out["attrs"]["range"] == "1.250" and out["attrs"]["model"] == "MiniMate Plus" assert out["attrs"]["range"] == "1.250" and out["attrs"]["model"] == "MiniMate Plus"
assert any(r[0] == "TranPPV" and r[1] == "mismatch" for r in out["results"]) # clipped at its own 1.250 ceiling: accepted under the saturation carve-out
assert ["TranPPV", "accepted"] in [r[:2] for r in out["results"]]
def test_bad_input_is_one_error_row(tmp_path): def test_bad_input_is_one_error_row(tmp_path):
@@ -128,7 +129,7 @@ def test_compare_to_marks_the_summary(tmp_path):
def test_file_prints_one_event(tmp_path, capsys): def test_file_prints_one_event(tmp_path, capsys):
assert run.main([str(FIX), str(FIX), "--file", "M007HVWF.K30W"]) == 0 assert run.main([str(FIX), str(FIX), "--file", "M007HVWF.K30W"]) == 0
out = capsys.readouterr().out out = capsys.readouterr().out
assert any("TranPPV" in line and "mismatch" in line for line in out.splitlines()) assert any("TranPPV" in line and "accepted" in line for line in out.splitlines())
# ── Final review fixes ────────────────────────────────────────────────────── # ── Final review fixes ──────────────────────────────────────────────────────
+30 -5
View File
@@ -114,8 +114,23 @@ def test_clipped_normal_range_is_accepted():
assert (res[f].verdict, res[f].carveout) == ("accepted", "saturation") assert (res[f].verdict, res[f].carveout) == ("accepted", "saturation")
def test_sensitive_range_8x_stays_a_mismatch(): def test_a_clipped_sensitive_event_is_accepted_at_its_own_ceiling():
# SFM reads the 1.250 range from the file; the clipped channels sit at 1.2506.
res = _results("M007HVWF.K30W", CARVEOUTS) res = _results("M007HVWF.K30W", CARVEOUTS)
assert res["GeoRange"].verdict == "match" and res["samples.Tran"].verdict == "match"
for f in ("TranPPV", "PeakVectorSum"):
assert (res[f].verdict, res[f].carveout) == ("accepted", "saturation")
def test_the_carveout_never_accepts_an_8x_value():
# What SFM produced while it assumed Normal on a Sensitive unit: 8x high.
# The saturation rule must leave it a mismatch.
raw = (FIX / "M007HVWF.K30W").read_bytes()
side = sfm_side(raw)
side.values.update(TranPPV=10.005, VertPPV=10.005, LongPPV=10.005, PeakVectorSum=17.33)
side.geo_ips_per_count = 10.0 / 32000
res = {r.field: r for r in compare(side, parse_xml_report_file(FIX / "M007HVWF_K30W_XML.XML"),
CARVEOUTS)}
assert res["TranPPV"].verdict == "mismatch" and res["samples.Tran"].verdict == "mismatch" assert res["TranPPV"].verdict == "mismatch" and res["samples.Tran"].verdict == "mismatch"
assert res["PeakVectorSum"].verdict == "mismatch" assert res["PeakVectorSum"].verdict == "mismatch"
@@ -133,13 +148,14 @@ def test_pvs_carveout_needs_oorange_from_blastware():
def test_pvs_carveout_needs_the_clipped_channel_at_the_ceiling(): def test_pvs_carveout_needs_the_clipped_channel_at_the_ceiling():
# 1.250 range, Blastware PVS OORANGE; an UNclipped channel's 8x value happens to land # 1.250 range, Blastware PVS OORANGE, but no channel Blastware clamped: an
# in the 1.250 band -- that must not let SFM's 8x vector sum through. # UNclipped channel's 8x value landing in the 1.250 band must not let a vector
# sum through, even one inside the sqrt(3) bound.
raw = (FIX / "M007HVWF.K30W").read_bytes() raw = (FIX / "M007HVWF.K30W").read_bytes()
ref = parse_xml_report_file(FIX / "M007HVWF_K30W_XML.XML") ref = parse_xml_report_file(FIX / "M007HVWF_K30W_XML.XML")
ref.scalars["TranPPV"] = "0.157" ref.scalars.update(TranPPV="0.157", VertPPV="0.157", LongPPV="0.157")
side = sfm_side(raw) side = sfm_side(raw)
side.values["TranPPV"] = 1.256 side.values.update(TranPPV=1.256, PeakVectorSum=2.0)
res = {r.field: r for r in compare(side, ref, CARVEOUTS)} res = {r.field: r for r in compare(side, ref, CARVEOUTS)}
assert res["PeakVectorSum"].verdict == "mismatch" assert res["PeakVectorSum"].verdict == "mismatch"
@@ -147,3 +163,12 @@ def test_pvs_carveout_needs_the_clipped_channel_at_the_ceiling():
def test_interval_mic_psi_matches(): def test_interval_mic_psi_matches():
# psi(L) report: every interval's "MicL Peak psi(L)" now converts right # psi(L) report: every interval's "MicL Peak psi(L)" now converts right
assert _results("T004JTRF.ME0H")["intervals.MicL Peak psi(L)"].verdict == "match" assert _results("T004JTRF.ME0H")["intervals.MicL Peak psi(L)"].verdict == "match"
def test_a_sensitive_range_event_now_matches():
gr = FIX.parent / "geo-range-11-01-26"
raw = (gr / "K557J1KB.RQ0W").read_bytes()
res = {r.field: r for r in compare(sfm_side(raw), parse_xml_report_file(gr / "K557J1KB_RQ0W_XML.XML"))}
for f in ("GeoRange", "TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
"samples.Tran", "samples.Vert", "samples.Long"):
assert res[f].verdict == "match", (f, res[f])