fix(sfm): wake a MiniMate before the read-back reconnect reads its serial (#9 review)

The reconnect in ce441a0 opened a fresh connection and sent a bare 0x15 (the
identity check) before any SESSION_RESET + POLL.  It exists for a unit that has
just started -- sensor check, then monitoring -- and a monitoring MiniMate
ignores a bare request until woken (measured 2026-04-08), so the identity read
would have timed out and the start reported unconfirmed anyway.  Now: open,
wake (the same retried wake the read-back uses), read the serial, read 0x1C --
the order the status read and the legacy write routes use.  Still one
reconnect, TCP only, nothing re-sent.

The fake gains bare_requests_ignored (off unless a test asks): a fresh
connection's reads time out, with the real client's TimeoutError, until woken.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-29 23:56:44 -04:00
1 parent 1626e521ae
commit dbd8a91661
3 files changed
+41 -4

No files matched your search

+5 -1
View File
@@ -249,8 +249,12 @@ class Series3Adapter:
address.key, exc)
client.close()
client.open()
# Wake first: the identity read is a bare 0x15, which a unit that
# has just started ignores until SESSION_RESET + POLL (the order
# the status read and the legacy write routes use: poll, then read).
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
self._check(client.read_serial(), serial, address)
return _woken_state(client)
return s3_run_state(client.get_monitor_status())
return run_change(