Handle cold-boot timeout for TCP connections
- bridges/tcp_serial_bridge.py: increase default boot_delay 2s → 8s to cover MiniMate Plus cold-start time (unit wakes from RS-232 line assertion but takes 5-10s to be ready for POLL_PROBE). - sfm/server.py: add _run_with_retry() — on TCP connections only, retries once on ProtocolError. Serial timeouts are not retried (usually a real fault). Confirmed behaviour: unit wakes purely from RS-232 line voltage, no software wake-up frame needed.
This commit is contained in:
@@ -55,8 +55,10 @@ DEFAULT_TCP_PORT = 12345
|
||||
CHUNK = 256 # bytes per read call
|
||||
SERIAL_TIMEOUT = 0.02 # serial read timeout (s) — non-blocking in practice
|
||||
TCP_TIMEOUT = 0.02 # socket recv timeout (s)
|
||||
BOOT_DELAY = 2.0 # seconds to wait after opening serial port before
|
||||
# forwarding data — mirrors the unit's startup beep
|
||||
BOOT_DELAY = 8.0 # seconds to wait after opening serial port before
|
||||
# forwarding data — unit cold-boot (beep + OS init)
|
||||
# takes 5-10s from first RS-232 line assertion.
|
||||
# Set to 0 if unit was already running before connect.
|
||||
|
||||
|
||||
# ── Bridge session ─────────────────────────────────────────────────────────────
|
||||
|
||||