docs(spec,plan): phase 5 -- the units' own limits, from Instantel's manuals

Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999.  The read-back reports any
value a unit does not take.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-03 19:30:07 -05:00
1 parent 71609e71ab
commit e3a77e421d
2 files changed
+39 -20

No files matched your search

@@ -150,7 +150,7 @@ def test_read_compliance_content_refuses_a_missing_frame():
- Produces (all pure). Each `content` is the 2,090-byte (Series 3) or 2,092-byte (Series 4) block.
- `editable_fields(content: bytes, series: int) -> list[dict]`. Each dict has `field`, `label`, `kind` (`"number"`, `"choice"`, `"text"` or `"bool"`) and `value`, plus as relevant `unit`, `min`, `max`, `choices` (a list of `{value, label}`) and `maxlength`.
- `field_values(content: bytes, series: int) -> dict[str, Any]`: the same fields, values only.
- `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, spans) and content-dependent (unit strings, the trigger against the range).
- `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, limits) and content-dependent (unit strings, the trigger against the range).
- `encode_setup(content: bytes, series: int, changes: dict) -> bytes`:
- same length as `content`;
- only the changed fields' bytes move;
@@ -172,18 +172,21 @@ def test_read_compliance_content_refuses_a_missing_frame():
| `record_mode` | 4 | `[5]` | `waveform`=1, `manual`=2, `histogram`=3, `combo`=4 |
| `sample_rate` | 3, 4 | `[6:8]` u16 BE | {1024, 2048, 4096} |
| `histogram_interval_s` | 3, 4 | `[8:10]` u16 BE | {2, 5, 15, 60, 300, 900} |
| `record_time_s` | 3, 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 20.0 |
| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 0.6, and ≤ the (new) range's full scale (10.0 / 1.25) |
| `record_time_s` | 3 | `[18:22]` f32 BE | 1.0 ≤ v ≤ `S3_MAX_RECORD_S[sample_rate]` = {1024: 104, 2048: 52, 4096: 26}, and ≤ 13 when `record_mode` is `histogram_continuous` (the **new** mode and rate if they change too) |
| `record_time_s` | 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 90.0 |
| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 10.0, a multiple of 0.001 (within 1e-9), and ≤ the (new) range's full scale (10.0 / 1.25) |
| `geo_range` | 3 | ch k `+29` u8, all three | `normal`=0, `sensitive`=1 |
| `geo_alarm_ips` | 3 (gated) | ch k `+38` f32 BE, all three | 0.005 ≤ v ≤ full scale |
| `job_number` | 3, 4 | `[40:42]` u16 BE | 0 ≤ v ≤ 65535 |
| `job_number` | 3, 4 | `[40:42]` u16 BE | 1 ≤ v ≤ 9999 |
| `job_number_shown` | 3, 4 | `[39]` bit `0x02` | bool |
| `note_1` … `note_4` | 3, 4 | value `[144+64n : 186+64n]`; label `[122+64n : 144+64n]` read only | printable ASCII 0x20–0x7E, ≤ 41 bytes, zero-filled to 42 |
Where the spans come from, recorded in the module as comments:
- **Trigger and record time:** 75,958 Blastware reports, 2016–2026, scanned 2026-11-03. 7,586 print a trigger: 0.005–0.500 in/s, 20 values, all in/s. 7,631 print a record time: 1.0–10.0 s.
- **The tops of the spans:** BE11529's 2026-04-20 writes and the UM20147 fixtures (trigger 0.6, record time 11), and BE9441's 10-26 setup (record time 20).
- **Job number:** bounded by its encoding (UM20147 keypad 0 → 1 → 1234). The read-back verifies it.
The limits are **the units' own, from Instantel's manuals** (Brian, 2026-11-03), cited in the module as comments:
- **Trigger** 0.005–10 in/s, steps of 0.001: MiniMate Plus manual 716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual 721U0201 Rev 06, *Geophone Trigger Level*.
- **Record time:**
- Micromate 1–90 s (*Record Time*).
- MiniMate: §4.4's *Maximum Record Times*, 1 MB unit, channels 1–4; §3.8.9, 13 s in Histogram Combo.
- **Job number** 1–9999: both manuals.
**A level write is refused** unless all three geophone channels' unit string, `ch +34:+38` with NULs and `.` stripped, equals `in`. Measured: `in.` and `in` both occur on UM20147. A unit set to Metric is unmeasured.
@@ -203,8 +206,11 @@ def test_s4_fixture_pairs_reproduce():
# for every ordered pair (a, b) of tests/fixtures/micromate-setup/*.bin whose differing bytes outside
# [2090:2092] all lie inside registry fields: encode_setup(a, 4, {f: field_values(b)[f] for differing f}) == b
def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 0.6} passes; a fake full scale below 0.6 refuses
def test_spans_refuse_outside_values(): ... # 0.004 and 0.61 in/s; 0.9 and 20.1 s; sample rate 8192; interval 30
def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 2.0} refuses (above 1.25); 1.25 passes; {"geo_trigger_ips": 2.0} alone on Normal passes
def test_limits_refuse_outside_values(): ... # 0.004 and 10.001 in/s; 0.3005 (not a 0.001 step); job 0 and 10000; S4 0.9 and 90.1 s;
# S3 at 4096 sps: 26 ok, 26.1 refused; S3 histogram_continuous: 13 ok, 13.1 refused;
# S3 {"sample_rate": 1024, "record_time_s": 100} passes from a 4096 sps block (the new rate counts);
# sample rate 8192; interval 30
def test_field_not_offered_for_the_series(): ... # geo_range on series 4 -> SettingsValueError naming the series
def test_alarm_is_read_only_until_measured(): ... # Series 3 geo_alarm_ips -> SettingsValueError while S3_ALARM_WRITE_MEASURED is False
def test_metric_unit_string_refuses_level_writes(): ... # ch +34 = b"mm\x00\x00" -> SettingsValueError; b"in.\x00" and b"in\x00\x00" pass