docs: the decode checker's first full run; correct the #53 note

First full run over DL2's 70,042 report-paired events (22 min, --jobs 4):
every expectation the spec set holds.  Setup and notes match everywhere;
geophone samples are exact on 6,491/6,524 waveforms across 2016-2026,
the other 33 being the 1.250 in/s range read 8x on SFM's Normal
assumption; every histogram is typed as a waveform without its filename
(#41); the three #53 files are the only waveform time mismatches.  New
findings: histogram PVS, mic psi, mic dB on ~1,000 events, ~37
sub-minute histograms, 26 histogram start dates.

The #53 note is corrected in place: those files decode as waveforms with
Blastware's full sample count; only their time falls back to the footer
start.  scratch/verify_bw_fields_against_xml.py is retired -- the
checker replaces it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-10-29 19:55:07 -04:00
1 parent c8fc649568
commit e9d352ad99
3 files changed
+32 -159

No files matched your search

+24
View File
@@ -14,6 +14,30 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
Read this first when picking the project back up.
- **🔑 The Series-3 decode checker (2026-10-29).** Goal: SFM produces everything
Blastware reports, from the event file alone (spec/plan in `docs/superpowers/`).
Run it with `scratch/check_s3_decode.py ~/dl2-archive/files ~/dl2-archive/xml`.
It decodes each event from its bytes only (no filename, no report) and
compares every field, sample and interval with Blastware's `_XML.XML`: 70,042
events, 2016–2026, ~22 min at `--jobs 4`. Run output (`summary.md`,
`details.json`, `changes.md`) goes to `~/dl2-archive/checker-runs/` and is
never committed. The rule: every mismatch is SFM's bug unless a carve-out
with evidence covers it.
**First full run:**
- ✅ Sample rate, record time, pre-trigger and notes match everywhere.
- ✅ Geophone samples are exact on 6,491 / 6,524 waveforms in every year. The
33 others are the 1.250 in/s range, 8× under SFM's Normal-range assumption.
- ❌ Every histogram reads as a waveform without its filename (#41), and
their start times are 1 s early (#51).
- ❌ Open findings:
- histogram PVS: SFM sums interval peaks, Blastware takes the per-interval
vector sum
- mic psi conversion
- mic dB off by 0.05–0.1 on ~1,000 events
- ~37 sub-minute histograms decode wrongly
- 26 histogram start dates are a day off
- ⬜ Not read yet: job number, ZC frequency, acceleration, displacement, time
of peak, sensor check, battery, calibration, range, units, monitor log.
- **The Series-4 LIVE wire protocol is reverse-engineered end to end
(2026-09-25).** `docs/micromate_protocol_reference.md` is the Series-4
Rosetta Stone, sibling to `instantel_protocol_reference.md`. **A Micromate